Advertisement

User's manual
Primor 1000 / 3000 / 3010/ Level 5
Content
1 General instructions __________________________________________________2
1.1 Liability notes _________________________________________________________2
1.2 Operating notes _______________________________________________________2
1.3 Notes on safety ________________________________________________________2
1.3.1 Security notes emergency lock _________________________________________2
2 Visual and acoustic signals____________________________________________3
3 Input units ____________________________________________________________3
4 Operating the lock ____________________________________________________3
4.1 Opening _____________________________________________________________3
4.2 Locking ______________________________________________________________3
5 Programming the lock ________________________________________________5
5.1 Master and user code __________________________________________________5
5.1.1 Programming the user code ___________________________________________5
5.1.2 Changing the master or user code _____________________________________5
5.1.3 Deleting the user ____________________________________________________5
5.2 Time delay and opening window_________________________________________6
5.2.3 Deleting the time delay _______________________________________________7
6 Testing the system ____________________________________________________8
7 Power supply and battery change _____________________________________8
© Carl Wittkopp GmbH - Errors and omissions excepted
Rel. 1.8
28.10.2016
User´s manual no. 9999-113-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Primor 1000 Level 5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wittkopp Primor 1000 Level 5

  • Page 1 5.2.2 Opening with activated time delay and opening window __________________7 5.2.3 Deleting the time delay _______________________________________________7 6 Testing the system ____________________________________________________8 7 Power supply and battery change _____________________________________8 © Carl Wittkopp GmbH - Errors and omissions excepted Rel. 1.8 28.10.2016 User´s manual no. 9999-113-1...
  • Page 2: General Instructions

    Primor 1000 / 3000 / 3010 / Level 5 1 General instructions • Please read the operating instructions carefully, before activating the lock. 1.1 Liability notes • We don’t assume liability for malfunctions due to incorrect operation, use of force or inappropriate handling. In cases of damage to property or valuables, which are due to incorrect locking of the safe, we also don’t assume liability.
  • Page 3: Visual And Acoustic Signals

    Primor 1000 / 3000 / 3010 / Level 5 2 Visual and acoustic signals Signal Explanation Comment  Right code  Wrong code or code denied Short signal Long signal LED flashes every 10 seconds Blocking time is active. ☼ LED flashes every 2 seconds Time delay is active.
  • Page 4: Opening With Key (Primor 3010) - Emergency Opening

    Primor 1000 / 3000 / 3010 / Level 5 4.3 Opening with key (Primor 3010) - emergency opening • In cases of code loss or an electronic malfunction, the lock can be opened with the key. • When the lock was opened by the key, it can only be locked by it again. •...
  • Page 5: Primor 1000 / 3000 / 3010/ Level

    Primor 1000 / 3000 / 3010 / Level 5 5 Programming the lock 5.1 Master and user code 5.1.1 Programming the user code (programme 1)   The master is able to program the user code, but not vice versa. 1.
  • Page 6: Time Delay And Opening Window

    Primor 1000 / 3000 / 3010 / Level 5 5.2 Time delay and opening window Only the master can program or delete the time delay. Time delay: 01 - 99 minutes - time to wait until the lock can be opened. Opening window: 01 - 19 minutes - within this time window the master or the user can open the lock with his code.
  • Page 7: Opening With Activated Time Delay And Opening Window

    Primor 1000 / 3000 / 3010 / Level 5 5.2.2 Opening with activated time delay and opening window   123456 1. Enter your 6-digit code e.g. mastercode. ☼ 2. Wait until the end of the time delay. ☼ 3. Opening window starts. 123456 4.
  • Page 8: Testing The System

    Primor 1000 / 3000 / 3010 / Level 5 6 Testing the system (programme 5) Press every number once. A functional key will be confirmed by a double signal. A key that was not identi-   fied is confirmed by a long signal and the functional test is aborted. The system has to be checked. 1.