Page 1
® thermoport • A patended system from Rieber which does more than just transport • For cooling / hot holding / regenerating / cooking – or several tasks at the same time • ® Various stainless steel and plastic thermoport...
If there are any deficits from your point of view, please do not hesitate to let us know. With your help, we will try to get even better. Address of manufacturer: Rieber GmbH & Co. KG Internet www.rieber.de Hoffmannstraße 44 Email info@rieber.de...
Clean ventilation grille at least every 4 weeks..................... 26 Dry the appliance to keep it ready for next use....................26 Fault - What now?............................... 27 Warranty and liability............................27 Information about applicable standards, laws, guidelines ................... 28 Technical data..............................28 Rieber GmbH & Co KG 05/2010...
Retainer for electrical mains plug Impact protection Wearing strips, replaceable Caster Ventilation grille Type plate ® ® Thermoporthybrid thermoport with controllable circulating air heating ® ® thermoport with controllable circulating air heating thermoport with non-controllable circulating air heating 05/2010 Rieber GmbH & Co KG...
The product data is indicated on the type plate (control panel). For detailed information on dimensions, order number, accessories: Please refer to the catalogue If you have any questions, please contact your local Rieber Service. Rieber GmbH & Co KG 05/2010...
• Chamber temperatures — chamber temperature and time can be adjusted at the top chamber temperature, time and steam can be adjusted at the bottom. 05/2010 Rieber GmbH & Co KG...
• During all phases of the product's life please ensure that the product is safely integrated into its environment. • Do not make any conversions or modifications to the product. Rieber GmbH & Co KG 05/2010...
The signal words DANGER - WARNING - CAUTION classify the possible degree of risk of bodily injury in an actual situation. Injuries can be prevented provided that the relevant instructions are followed. The warning triangle symbol indicates a "General Danger". 05/2010 Rieber GmbH & Co KG...
The product switches itself off automatically in the event of a fault to the control system. • To increase your safety we recommend you install an earth leakage circuit breaker with a tripping current of 30 mA upstream of the appliance. Rieber GmbH & Co KG 05/2010...
Keep combustible materials away from the product. • Keep unauthorised persons away from the product. • Never operate the product unsupervised. • Only use Gastronorm containers made from heat-resistant or non flammable materials, otherwise there is a risk of fire. 05/2010 Rieber GmbH & Co KG...
/ label on the appliance. • Open transport packaging at the positions provided for this purpose. Do not tear or cut. • Check scope of delivery using the dispatch note. • Remove any protective foils from the appliance. Rieber GmbH & Co KG 05/2010...
Otherwise, the appliance may be damaged. • • • • After transport, put the appliance in ist correct position and allow it to rest for at least one hour before switching it on. 05/2010 Rieber GmbH & Co KG...
Bottom: Options for setting chamber temperature, time and steam. Program 5: Two chamber temperatures Top: Options for setting chamber temperature and time. Bottom: Options for setting chamber temperature, time and steam. Program 6: Menu For selecting stored programs. Rieber GmbH & Co KG 05/2010...
The adjusted value is saved automatically. Calling up the target core temperature: Press the core temperature function button. • The target temperature is displayed. • After approx. 10 seconds the display will revert to the current core temperature. 05/2010 Rieber GmbH & Co KG...
Page 15
Back to program selection. The program currently running will be stopped. Activating standby - mode: Press STOP – button (13) again and keep it pressed for approx. 5 seconds: • Standby mode is activated. Rieber GmbH & Co KG 05/2010...
Page 16
Put in the cooling pellets, otherwise cooling is not possible. Passive cooling with circulating air + cooling pellets. • Air circulation begins when this program is started. • The current chamber temperature is shown in the display. 05/2010 Rieber GmbH & Co KG...
Page 17
Put in the insulated divider. For the “2 chamber temperatures” program, the lower chamber temperature is set via the core temperature button. • The indicator flashes on the time function button (flashing = may be changed) Rieber GmbH & Co KG 05/2010...
Page 18
Press STOP – button again and keep it pressed for approx. 5 seconds: Back to program selection. • The program currently running will be stopped. Press STOP – button again and keep it pressed for approx. 5 seconds: • Standby mode is activated. 05/2010 Rieber GmbH & Co KG...
By the second pull of the lock the door opens completely. Charging: You can find a spreadsheet with advices for optimal charging of thermoport hybrid 200 under: www.Rieber.de / service center / users guides. Rieber GmbH & Co KG 05/2010...
• Fill in water; 20 mm high or 2 liters! • Connect electrically. After approx. 30 minutes, with lid closed, the operating temperature of apprx. 95° C is reached. 05/2010 Rieber GmbH & Co KG...
Otherwise, put the appliance in its correct position and allow it to rest for at least one hour before switching it on. ® The control panel of the thermoport Display / indicators Function buttons Display Standby Standby START Heating / cooling Minus Plus Rieber GmbH & Co KG 05/2010...
DANGER! Danger of electric shock. Risk of death. • Remove the product from the mains before cleaning. • Never direct a jet of water at electrical components such as heater, controller or ventilation grille. 05/2010 Rieber GmbH & Co KG...
In case of liquid meals, close the Gastronorm – containers using water-tight press-in lids with all-round silicone seal. Cold meals: • Fill into the Gastronorm – containers as cold as possible; the temperature should not increase above +7° C. 7.3 After use • Clean the appliance. Rieber GmbH & Co KG 05/2010...
When reinstalling them later, ensure that the heating element is engaged properly. • The heating element has proper contact with the door and the heating element panel is in a horizontal position. ® thermoport toploader with non-controllable heating 05/2010 Rieber GmbH & Co KG...
Clean the appliance with a mild detergent diluted in hot water. After cleaning, rub surfaces dry with a soft cloth. User tip • We recommend Rieber cleaning agent for stainless steel for cleaning stainless steel. • Is an especially tough yet soft cleaner, produces a dazzling shine, cleans and protects in one.
View on bottom side of appliance with intake air opening. opening. Dry the appliance to keep it ready for next use • Dry the appliance. Allow residual moisture to escape. • Store appliance at room temperature. 05/2010 Rieber GmbH & Co KG...
Customer service needs information about the type and number of the appliance. (type plate on control panel) If you have a fault you cannot remedy yourself, please get in touch with your Rieber specialist dealer or Rieber central customer services (see address on Page 2) Disposing of your product Your appliance is made of high-quality material which can be reused / recycled.
44,4 0,250 IP X3 1600 K cool 70,4 0,170 IP X3 2000 K cool 89,7 0,170 IP X3 3000 K cool 0,170 IP X3 Hybrid 140 3,300 IP X5 Hybrid 200 3,300 IP X5 05/2010 Rieber GmbH & Co KG...
Need help?
Do you have a question about the thermoport Series and is the answer not in the manual?
Questions and answers