Summary of Contents for Keysight Technologies E5080B

  • Page 1 Keysight E5080B ENA Series RF Network Analyzers Installation Guide...
  • Page 2: Safety Notices

    FAR and the DFARS agreement and written consent from used or copied only in accordance and are set forth specifically in Keysight Technologies, Inc. as with the terms of such license. writing elsewhere in the EULA. governed by United States and...
  • Page 3: Caution

    When you notice any of the unusual conditions listed below, immediately terminate operation and disconnect the power cable. Contact your local Keysight Technologies sales representative or authorized service company for repair of the instrument. If you continue to operate without repairing the instrument, there is a potential fire or shock hazard to the operator.
  • Page 4: Manufacturer's Declaration

    European Directives, and carries the CE marking accordingly: • The Low Voltage Directive 2014/35/EU • The EMC Directive 2014/30/EU To obtain Declaration of Conformity, please contact your local Keysight Technologies sales office, agent or distributor. Keysight E5080B ENA Series RF Network Analyzers...
  • Page 5: Safety Notice Supplement

    • This equipment is tested in stand-alone condition and in combination with the accessories supplied by Keysight Technologies against the requirement of the standards described in the Declaration of Conformity. If it is used as a system component, compliance of related regulations and safety requirements are to be confirmed by the builder of the system.
  • Page 6: General Safety Precautions

    The E5080B complies with INSTALLATION CATEGORY II as well as POLLUTION DEGREE 2 in IEC61010-1. The E5080B is an INDOOR USE product. The LEDs in the E5080B are Class 1 in accordance with IEC60825-1, CLASS 1 LED PRODUCT. • Ground the Instrument To avoid electric shock, the instrument chassis and cabinet must be grounded with the supplied power cable’s grounding prong.
  • Page 7: Safety Symbols

    Certification Keysight Technologies certifies that this product met its published specifications at the time of shipment from the factory. Keysight Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology, to the extent allowed by the Institution’s calibration facility or by the calibration facilities of other...
  • Page 8: Documentation Warranty

    Exclusive Remedies The remedies provided herein are Buyer’s sole and exclusive remedies. Keysight Technologies shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory.
  • Page 9: Manuals For E5080B

    The online help provides the information about the quick start, measurement operation, programming, built-in VBA, I/O interface This is pre-installed in the E5080B. Press [Help] hard key on the front panel to open. Quick Start helps in understanding the E5080B operation quickly.
  • Page 10 Caution Manuals for E5080B Keysight E5080B ENA Series RF Network Analyzers...
  • Page 11: Table Of Contents

    Initial Registration of E5080B........
  • Page 12 Procedure to execute the factory recovery ........23 Keysight E5080B Installation Guide...
  • Page 13: Installation

    Keysight E5080B ENA Series RF Network Analyzers Installation Guide Installation This chapter provides information about how to set up the Keysight E5080B. Checking the Shipment After you receive the analyzer, carry out checks during unpacking according to the following procedure.
  • Page 14: Environmental Requirements

    If an abnormality is detected in step 1, contact the company that transported the analyzer as well as your nearest Keysight Technologies sales and service office. Environmental Requirements Set up the E5080B where the following environmental requirements are met. Operating Environments Ensure that the operating environment meets the following requirements. Temperature 0˚C to 40˚C...
  • Page 15: Protection Against Electrostatic Discharge (Esd)

    19, the power supply is disconnected by removing the power cable’s connector plug from either the AC outlet or the E5080B unit. When installing the E5080B, ensure that there is sufficient free space around the unit to permit quick disconnection of the plug (from AC outlet or E5080B unit) in case of emergency.
  • Page 16: Power Supply

    350 W Verification and Connection of Power Cable The three-wire power cable attached to the E5080B has one wire serving as a ground. Using this power cable allows the E5080B to be grounded, thereby protecting you against electrical shock from the power outlet.
  • Page 17: Blown Fuses

    Connecting the BNC Adaptor (Option 1E5) When the E5080B is equipped with Option 1E5 (high-stability frequency standard), connect the BNC adapter between the 10 MHz REF OVEN and the 10 MHz REF IN connectors on the rear panel. The BNC adapter is included in Option 1E5.
  • Page 18: Starting The E5080B

    Normal operation is confirmed by the self-test if no error message appears. Turning the Power OFF Step 1. To turn OFF the power of the E5080B, first, press this standby switch or send a shutdown command from the external controller to activate the shutdown process (the process of software and hardware necessary to turn OFF the power supply).
  • Page 19: Disconnection From Supply Source

    Power cable receptacle Disconnection from Supply Source The power supply of the E5080B is cut off by disconnecting the plug of the power cable (on either AC outlet side or E5080B side). When it is necessary to disconnect the power supply in order to avoid shock hazards, etc., pull out the power cable plug from either the AC outlet side or the E5080B side.
  • Page 20: Initial Registration Of E5080B

    Initial Registration of E5080B Initial Registration of E5080B When you start up the E5080B for the first time, you need to perform the initial registration of the Windows operating system of the E5080B. When the Windows agreement message box appears, click Agree. The rest of the procedure runs automatically.
  • Page 21: Troubleshooting

    Keysight E5080B ENA Series RF Network Analyzers Installation Guide 2 Troubleshooting This chapter describes the troubleshooting during start up and the procedure of the operating system (OS) recovery when the Windows OS has been damaged. Troubleshooting during Startup When you encounter the problem during start up, see Table 2-1.
  • Page 22: System Recovery

    Troubleshooting System Recovery System Recovery By executing system recovery, you can return the system of the E5080B (the Windows operating system and the firmware) to the factory state (at the time of purchase Strictly follow the steps described below. If you do any operation other than the following steps, the system may not be recovered.
  • Page 23 Step 2. Disconnect all of the USB device from the USB ports. Step 3. Connect the keyboard to the E5080B. Step 4. Press the standby switch of the E5080B to turn it ON. Step 5. When the screen as shown in the figure below appears, select Instrument Image Recovery System and press [Enter].
  • Page 24 Step 6. Software End User License Agreement appears. Press [Agree]. Figure 2-2 Software End User License Agreement Step 7. Type 2 to select Recover the original factory system image option and press [Enter]. Figure 2-3 System recovery selection screen Keysight E5080B ENA Series RF Network Analyzers...
  • Page 25 Step 12. After the restart, execute initial registration. For information on the execution procedure, refer to “Initial Registration of E5080B” on page 20 Never turn OFF the power during the system recovery because doing so may cause serious damage to the E5080B.
  • Page 26 Troubleshooting System Recovery Keysight E5080B ENA Series RF Network Analyzers...
  • Page 27 Exclusive Remedies Inspection checking the shipment power check the power supply disconnection from supply source power cable options verification and connection of power cable safety symbols shutdown turning the power OFF System Recovery How to Execute Keysight E5080B Installation Guide...
  • Page 28 Index Keysight E5080B Installation Guide...
  • Page 29 This information is subject to change without notice. © Keysight Technologies 2019 Edition 1, March 2019 *E5080-90010* E5080-90010 www.keysight.com...