Nice Robus350 Instructions And Warnings For The Fitter

Nice Robus350 Instructions And Warnings For The Fitter

Hide thumbs Also See for Robus350:

Advertisement

sliding gates
Robus
350
Instructions and warnings for the fitter
Istruzioni ed avvertenze per l'installatore
Instructions et recommandations pour l'installateur
Anweisungen und Hinweise für den Installateur
Instrucciones y advertencias para el instalador
Instrukcje i uwagi dla instalatora
Aanwijzingen en aanbevelingen voor de installateur

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Robus350 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nice Robus350

  • Page 1 sliding gates Robus Instructions and warnings for the fitter Istruzioni ed avvertenze per l’installatore Instructions et recommandations pour l’installateur Anweisungen und Hinweise für den Installateur Instrucciones y advertencias para el instalador Instrukcje i uwagi dla instalatora Aanwijzingen en aanbevelingen voor de installateur...
  • Page 2: Table Of Contents

    Robus Table of contents: page Warnings Additional information Programming keys Product description and applications Programming Operating limits Level one functions (ON-OFF functions) 7.2.1 Typical system Level one programming 7.2.2 List of cables (ON-OFF functions). Level two functions 7.2.3 Installation (adjustable parameters) Preliminary checks Level two programming 7.2.4...
  • Page 3: Warnings

    Due to the dangers which may arise during both the installation and use tation” for this automation. of the ROBUS350, installation must be carried out in full respect of the • Check whether additional devices are needed to complete the automa-...
  • Page 4: List Of Cables

    Note 5: special devices which enable connection even when the leaf is moving must be used to connect movable edges to sliding leaves. 3) Installation The installation of ROBUS350 must be carried out by qualified personnel in compliance with current legislation, standards and regulations, and the directions provided in this manual.
  • Page 5: Preliminary Checks

    • Never immerse components in water or other liquids. its”. • Keep ROBUS350 away from sources of heat and open flames and • Check that the static friction (that is, the force required to start the acid, saline or potentially explosive atmospheres. Situations such movement of the leaf) is less than half the “maximum torque”, and...
  • Page 6: Installation Of The Various Devices

    If other devices are needed, install them following the directions provided in the corresponding instructions. Check this in paragraph “3.5 Description of electrical connections” and the devices which can be connected to the ROBUS350 in Figure 2. 3.4) Electrical connections...
  • Page 7: Description Of The Electrical Connections

    LUCYB S.C.A. MOFB MOSE 3.5) Description of the electrical connections Here follows a brief description of the electrical connections. Please STOP: input for the devices which block or eventually stop the refer to the “7.3. Adding or Removing Devices” paragraph for further manoeuvre in progress.
  • Page 8: Power Supply Connection

    4.2) Power Supply Connection The connection of ROBUS350 to the mains must be made by qualified and experienced personnel in possession of the necessary requi- sites and in full respect of the laws, provisions and standards currently in force. As soon as ROBUS350 is energized, you should check the following: and the lamp LED connected to the “Open Gate Indicator”...
  • Page 9: Memorization Of Radio Transmitters

    The “SM” radio receiver connector for SMXI or SMXIS type radio receivers has been provided in order to enable the user to control ROBUS350 from a distance (see Figure 20). Each radio transmitter is recognised by the said receiver by means of a “code” which is differ- ent from that of any other transmitter.
  • Page 10: Remote" Memorization

    Nice S.p.a., Via Pezza Alta 13, 31046 Rustignè di Oderzo (TV) Italy NICE S.p.a. declares that radio receiver models SMXI, SMXIS and the relative FLO2R-S and SM2 transmitters conform to the essential requi- sites specified in Directive R&TTE 1999/5/CE, for the use the devices have been manufactured for.
  • Page 11: Testing 11

    “commissioning”), serial number, year of man- ufacture and “CE” marking. 6) Maintenance and Disposal This charter provides information about how to draw up a maintenance schedule, and the disposal of ROBUS350 6.1) Maintenance The automation must be subjected to maintenance work on a regular 2.
  • Page 12: Additional Information

    If pre-flashing is inactive, the flashing light will switch on when the manoeuvre starts. During the normal functioning of the ROBUS350, LEDs L1….L6 will either be on or off depending on the state of the function they represent. For example, L1 will be on if the “Automatic Closing” function is active.
  • Page 13: Level One Programming (On-Off Functions)

    7.2.2) Level one programming (ON-OFF functions). Level 1 functions are all factory set to “OFF”. However, they can be changed at any time as shown in Table 13. Follow the procedure care- fully, as there is a maximum time of 10 seconds between pressing one key and another. If a longer period of time lapses, the procedure will finish automatically and memorize the modifications made up to that stage.
  • Page 14: Level Two Programming

    All the parameters can be adjusted as required without any con- • Wear and weather conditions may affect the movement of the traindication; only the adjustment of the “motor force” could require gate, therefore periodic re-adjustments may be necessary. special care: •...
  • Page 15: Level Two Programming Example

    Wait 10 seconds before leaving the programme to allow the maximum time to lapse. 7.3) Adding or Removing Devices Devices can be added to or removed from the ROBUS350 automa- connected to “BLUEBUS” and “STOP” input as explained in para- tion system at any time.
  • Page 16: Photocells

    In an automation for slid- ing gates, with ROBUS350 it is possible to install the photocells as shown in Figure 22.
  • Page 17: Connection To Other Devices

    LED on the transmitter lights up The user is unable to command manoeuvres Check that ROBUS350 is being fed 230V voltage from the power supply. Check to see and the “BLUEBUS” LED fails to flash. if any fuses have blown. If necessary, identify the reason for the failure and then replace the fuses with others having the same current rating and characteristics.
  • Page 18: Flashing Light Signalling

    7 flashes 7.7.2) Signals on the control unit On the ROBUS350 control unit there is a set of LED’s each of which can give special indications both during normal operation and in case of malfunctions.
  • Page 19: Accessories

    Flashing Function programming in progress. 7.8) Accessories The following optional accessories are available for ROBUS350: For information on the complete range of accessories, refer to the • PS124 24 V Buffer battery – 1.2Ah with integrated charger battery Nice s.p.a. product catalogue.
  • Page 20: Technical Characteristics

    8) Technical characteristics Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. In any case, the manufacturer guarantees their functionality and fitness for the intended purposes. All the technical characteristics refer to a room temperature of 20°C (±5°C).
  • Page 21: Instructions And Warnings For Users Of Robus Gearmotor

    This operation antee high levels of safety and security. They are has been carefully designed by Nice to make it equipped with detection devices that prevent move- extremely easy, without any need for tools or physical ment if people or objects are in the way, guaranteeing exertion.
  • Page 22 Nice products. You will get the the control is released the gate will stop. services of a specialist and the most advanced prod- ucts available on the market, superior performances and maximum system compatibility.

Table of Contents