Page 1
BOTTARO WEIGHING SYSTEMS Via G.Marconi 24050 , Grassobbio BG , Tel 035/525681 Fax 035/525689 www.bottaro-bilance.it WEIGHING INSTRUMENT MB02 Instructions for use Document N°: M02P - I - FILENAME : mb02 rev.4 rel 1.16...
Page 2
This publication may contain information with typographic errors. Corrections will be included in new editions of the publication. Edition dated 26/02/2014- Rev. “0” - II - FILENAME : mb02 rev.4 rel 1.16...
Multi-division function (MD) 4.1.3 Multiple range weighing function (MR) INTERFACES Maxidisplay repeater device 5.1.1 Maxidisplay cable connection 5.1.2 Transmission string format Input connection diagram 5.3 Rear panel Loading cell connector Metric plate location - III - FILENAME : mb02 rev.4 rel 1.16...
Page 4
= thousandth of a second = note, important information or procedure = attention, information or procedure that, if not followed exactly, could cause death or severe personal injury = mains socket = not approved function - 1 - FILENAME : mb02 rev.4 rel 1.16...
This could occur in the following situations: The device shows visible signs of damage or tampering. There is a visually obvious malfunction. The device was stored for a long time in unsuitable conditions. - 3 - FILENAME : mb02 rev.4 rel 1.16...
Do not stack objects on it. Caution is recommended when handling the instrument. Store the instruments as they were received. Do not stack pallets or any other type of object on it. - 4 - FILENAME : mb02 rev.4 rel 1.16...
- Combination with data acquisition systems and computers - Management of coordination devices for weighing operations - Network connections for data transfer - Handling systems - With devices for automating the scale operation through automatic material handling. - 5 - FILENAME : mb02 rev.4 rel 1.16...
This is lit when the gross weight is negative or between 0 and 20 e reduced to 5 in applications for determining a transport fee. 4: Non metrological data symbol When lit, the data shown is not bound to metric verification. - 6 - FILENAME : mb02 rev.4 rel 1.16...
This display will remain active for about 5 seconds after which the terminal will automatically return to the normal weight display. This function is only possible if it was enabled in the setup program. - 8 - FILENAME : mb02 rev.4 rel 1.16...
Entering tare weight (preset tare) If a tare is entered, the maximum value of the tare may not be greater than the Max value, which is the maximum capacity of the first partial weighing field. - 9 - FILENAME : mb02 rev.4 rel 1.16...
The tare value, which can either be acquired or entered, is equal to Max In multiple range weighing instruments using indication notification is given of which weighing range is being used. - 10 - FILENAME : mb02 rev.4 rel 1.16...
3 0 Vdc 12 Vdc Example of connection between MB01 weight detection terminal and external systems: Input 3 Input 2 Input 1 Connect PINS 9 10 11 DB 15 male connector - 12 - FILENAME : mb02 rev.4 rel 1.16...
Page 16
CALIBRATION ZONE ZONE A ZONE SICILY 2 Installation parameters Installation date: ........Instrument S/N ........Installer: ........Installing co.: ........Highlight the installation parameters and attach a copy to the instrument - 13 - FILENAME : mb02 rev.4 rel 1.16...
The figure shows the layout of the external instrument connection in the table version: Description: INPUT VOLTAGE 12 Vdc CONNECTOR FOR DIGITAL INPUTS LOAD CELL CONNECTOR SERIAL CHANNEL CONNECTOR 1 RS 485 - 14 - FILENAME : mb02 rev.4 rel 1.16...
Please Note: connect to pin 3 on the connector DB 9 male connector Pin no. meaning - POWER SUPPLY - SENSE Shield + SENSE + POWER SUPPLY - OUT + OUT - 15 - FILENAME : mb02 rev.4 rel 1.16...