BOTTARO WEIGHING SYSTEMS MB02 Instructions For Use Manual

Weighing instrument

Advertisement

Quick Links

BOTTARO WEIGHING SYSTEMS
Via G.Marconi 24050 , Grassobbio BG , Tel 035/525681 Fax 035/525689 www.bottaro-bilance.it
WEIGHING INSTRUMENT
MB02
Instructions for use
Document N°: M02P
- I -
FILENAME :
mb02 rev.4 rel 1.16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MB02 and is the answer not in the manual?

Questions and answers

Summary of Contents for BOTTARO WEIGHING SYSTEMS MB02

  • Page 1 BOTTARO WEIGHING SYSTEMS Via G.Marconi 24050 , Grassobbio BG , Tel 035/525681 Fax 035/525689 www.bottaro-bilance.it WEIGHING INSTRUMENT MB02 Instructions for use Document N°: M02P - I - FILENAME : mb02 rev.4 rel 1.16...
  • Page 2 This publication may contain information with typographic errors. Corrections will be included in new editions of the publication. Edition dated 26/02/2014- Rev. “0” - II - FILENAME : mb02 rev.4 rel 1.16...
  • Page 3: Table Of Contents

    Multi-division function (MD) 4.1.3 Multiple range weighing function (MR) INTERFACES Maxidisplay repeater device 5.1.1 Maxidisplay cable connection 5.1.2 Transmission string format Input connection diagram 5.3 Rear panel Loading cell connector Metric plate location - III - FILENAME : mb02 rev.4 rel 1.16...
  • Page 4 = thousandth of a second = note, important information or procedure = attention, information or procedure that, if not followed exactly, could cause death or severe personal injury = mains socket = not approved function - 1 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 5: Introduction

    - 2 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 6: Safety

    This could occur in the following situations:  The device shows visible signs of damage or tampering.  There is a visually obvious malfunction.  The device was stored for a long time in unsuitable conditions. - 3 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 7: Testing And Installation

    Do not stack objects on it.  Caution is recommended when handling the instrument. Store the instruments as they were received. Do not stack pallets or any other type of object on it. - 4 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 8: Introduction

    - Combination with data acquisition systems and computers - Management of coordination devices for weighing operations - Network connections for data transfer - Handling systems - With devices for automating the scale operation through automatic material handling. - 5 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 9: Led Indicators

    This is lit when the gross weight is negative or between 0 and 20 e reduced to 5 in applications for determining a transport fee. 4: Non metrological data symbol When lit, the data shown is not bound to metric verification. - 6 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 10: List Of Selectable Functions

    To remove the tare from the memory, just press the key again. - 7 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 11: Using The Terminal

    This display will remain active for about 5 seconds after which the terminal will automatically return to the normal weight display. This function is only possible if it was enabled in the setup program. - 8 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 12: Multi-Division Function (Md)

    Entering tare weight (preset tare) If a tare is entered, the maximum value of the tare may not be greater than the Max value, which is the maximum capacity of the first partial weighing field. - 9 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 13: Multiple Range Weighing Function (Mr)

    The tare value, which can either be acquired or entered, is equal to Max In multiple range weighing instruments using indication notification is given of which weighing range is being used. - 10 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 14: Interfaces

    Num. of Digits Description meaning Start char space 1 dig weight 2 dig weight 3 dig weight 4 dig weight 5 dig weight 6 dig weight 7 dig weight End char - 11 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 15: Input Connection Diagram

    3 0 Vdc 12 Vdc Example of connection between MB01 weight detection terminal and external systems: Input 3 Input 2 Input 1 Connect PINS 9 10 11 DB 15 male connector - 12 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 16 CALIBRATION ZONE ZONE A ZONE SICILY 2 Installation parameters Installation date: ........Instrument S/N ........Installer: ........Installing co.: ........Highlight the installation parameters and attach a copy to the instrument - 13 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 17: Rear Panel

    The figure shows the layout of the external instrument connection in the table version: Description: INPUT VOLTAGE 12 Vdc CONNECTOR FOR DIGITAL INPUTS LOAD CELL CONNECTOR SERIAL CHANNEL CONNECTOR 1 RS 485 - 14 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 18: Loading Cell Connector

    Please Note: connect to pin 3 on the connector DB 9 male connector Pin no. meaning - POWER SUPPLY - SENSE Shield + SENSE + POWER SUPPLY - OUT + OUT - 15 - FILENAME : mb02 rev.4 rel 1.16...
  • Page 19: Metric Plate Location

    5.5 Metric plate location FIGURE B FIGURE A IDENTIFICATION PLATE CLOSING FASTENERS - 16 - FILENAME mb01 rev.4 re/ 1.16...

Table of Contents