Setting Parameters; Elimination Of Faults - strapex SMA 30 Operating Instructions Manual

Automatic machine for plastic strapping
Table of Contents

Advertisement

Available languages

Available languages

LED-A
INC
DEC
Fig. 16
The list with all parameter values and the
factory settings are on page 45.
Faults can often only be eliminated by
qualifi ed personnel.
FAULT
Machine does not work, status lamp is on
Machine does not work, status lamp is off
Strap feeding malfunction
Strap take-up malfunction
Strap feeding does not stop
03.11
LED-B
M+
M-

9.6 SETTING PARAMETERS

– Loosen eight phillips head screws and remove rear
cover.
– Loosen two phillips head screws and remove cover
of control box.
LED-A
Function mode
LED-B
Parameter values
INC
Function mode increase P0>P7>F0
DEC
Function mode decrease P0>H7>E7
M+
Increasing parameter values
M-
Decreasing parameter values
Read mode (PCB):
– M+ or M- = to read the current setting values
Settings (PCB):
– M+ and M- =
Simultaneously for three seconds,
enter setting mode.
– M+ or M- =
Select the function mode.
– INC or DEC =
Change parameter values.
– M+ and M- =
Simultaneously, store the values.

9.7 ELIMINATION OF FAULTS

Preconditions
– Machine is correctly connected to the mains supply.
– Micro fuses in the electrical part are not defective,
see chapter 9.4).
CAUSE / ACTION
– Check connector or cables.
– Check relay on reset switch.
– Check contact or breakdown of stop button.
– Check contact of start button button.
– Check belt and pulley of motor M23, and motor
M26.
– Check whether the machine is connected to the
mains.
– Check whether the mains switch is on.
– Fuse is blown or out of place (refer to Chapter 9.3)
– Check for loose cables.
– Remove strap and re-insert it (see Chapter 6.2).
– Check S44 works improperly (malfunction).
Check position for proper contact.
– Check time setting "F1(on PCB)".
– Check belt and pulley of motor M26.
– Check position or proper contact of switch S39.
– Check belt and pulley of motor M26.
– Flaps of strap way or of arch do not return com-
pletely to their proper position.
– Check time setting "F1(on PCB)".
Strapex SMA 30
27

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMA 30 and is the answer not in the manual?

Questions and answers

Table of Contents