  • Page 1 Operating Manual...
  • Page 2: Table Of Contents

    Scope of delivery ................11 Your device at a glance ..............12 First operation ................14 Connection..................14 Connection of a LAP-TEQ Sensor PLUS (optional) ......17 Fastening the magnetic mounting bracket ........18 Operation ..................19 Power on/off ..................19...
  • Page 3 Trigonometric correction / length unit ......... 20 Cleaning and care................22 Malfunctions and troubleshooting ..........23 Service centre ................... 24 Observe ambient conditions ............. 25 Storage .................... 26 Disposal ................... 27 Technical data ................. 28 Declaration of Conformity ............. 29 LAP-TEQ Elevation...
  • Page 4: Before You Get Started

    Before you get started… Before you get started… Intended use The LAP-TEQ Elevation Sensor is designed to determine the correct mounting height for speakers. The LAP-TEQ Elevation Sensor measures the vertical distance between the unit and the surface directly beneath. The measured distance is displayed on a LAP-TEQ Display PLUS or a LAP-TEQ Motion System, to be purchased separately.
  • Page 5 Before you get started… Caution! Potential danger of injury! Dangerous situation that can result in injuries. Attention! Danger of damage to device! Situation that can result in material damage. Notice Information provided for better understanding of the processes. LAP-TEQ Elevation...
  • Page 6: For Your Safety

    For your safety For your safety Warning! Failure to comply with the safety information and instructions can cause electric shock, fire and/or severe injuries. ► Read all safety information and instructions. General safety information  Store all safety information and instructions for future reference. The term device used in the safety information refers to mains-powered devices (with a mains cable) and to battery-powered devices (without a mains cable).
  • Page 7: About Laser Beams

     If you use the device outdoors, use only extension cables that are suitable for outdoor use. The use of an extension cable that is suitable for outdoor use reduces the risk of damage to the device. LAP-TEQ Elevation...
  • Page 8: About Strong Magnets

    For your safety About strong magnets  Magnets can affect the functioning of pacemakers and implanted defibrillators. If you wear one of these devices, stay out of the direct vicinity of the magnets!  The holding force of magnets can weaken. Be aware at all times that a magnet can become demagnetised, causing the unit to fall.
  • Page 9: Service

    This device is classified as a class 2 laser product in accordance with the international standard IEC 60825. It operates with a visible laser beam, which is not dangerous in normal operation.  Do not remove or cover symbols located on your device. Illegible information must be replaced immediately. LAP-TEQ Elevation...
  • Page 10 For your safety Read and comply with the operating manual prior to operating the device. Danger of eye injuries! Never look directly into the laser beam. V-11/2018...
  • Page 11: Description Of Product

    Scope of delivery The standard set includes the following components:  2x: LAP-TEQ Elevation  2x: LAP-TEQ mounting bracket (magnetic)  2x: Mechanical quick-release connector (already mounted on the unit and on the mounting bracket at time of delivery) ...
  • Page 12: Your Device At A Glance

    7. Holder for mechanical quick-release connector 8. Laser beam output 9. Holder for mechanical quick-release connector 10. Strain relief for XLR cable to display unit (or for XLR cable to LAP-TEQ Sensor PLUS) 11. LAP-TEQ mounting bracket (magnetic) 12. Mechanical quick-release connector with swivel joint (already mounted on unit at time of delivery) 13.
  • Page 13 This allows you to determine whether the end point of the measurement is correct. The magnetic mounting bracket can also be used to mount a LAP-TEQ Sensor PLUS. It is then possible to simultaneously measure the height and the vertical alignment.
  • Page 14: First Operation

    First operation First operation Connection Attention! Danger of damage to device! Moisture and liquids can damage the components or electronic circuits in the device. ► Do not switch the device on if it is damp. ► If the device is already switched on, switch it off. ►...
  • Page 15 (1) of the magnetic mounting bracket. ► Insert the arrester cable (4) through the safety shackle (5) and the slot (6) on the magnetic mounting bracket. ► Connect the snap hook of the arrester cable (4) to the loop. LAP-TEQ Elevation...
  • Page 16 First operation ► Connect the elevation unit (1) to the input “IN”, and the display unit (3) using a standard 3-pin XLR cable (2). There is no limit to the number of elevation units that can be connected successively to a display unit. For example, three elevation units can be used to check the correct orientation of a left and right PA system, as well as a centre cluster.
  • Page 17: Connection Of A Lap-Teq Sensor Plus (Optional)

    First operation Connection of a LAP-TEQ Sensor PLUS (optional) ► Mount the LAP-TEQ Sensor PLUS (1) likewise on the flying frame of the magnetic mounting bracket (see operating instructions for LAP-TEQ PLUS). ► Connect the LAP-TEQ Sensor PLUS (1) to the “THRU” socket of the elevation unit (3) by means of a standard 3-pin XLR cable (2).
  • Page 18: Fastening The Magnetic Mounting Bracket

    First operation Fastening the magnetic mounting bracket ► Place the magnetic mounting bracket on the upper edge of the flying frame. ► Use the arrester cable to secure the magnetic mounting bracket on the flying frame against falling down. ► Insert the XLR cable in a loop through the strain relief on the magnetic mounting bracket.
  • Page 19: Operation

    If the system has started up correctly, the red laser lights up and the current distance is displayed. If a LAP-TEQ Sensor PLUS is connected in addition, the current angle reading will be displayed simultaneously. The measurement is refreshed continuously; in unfavourable conditions (cp.
  • Page 20: Trigonometric Correction / Length Unit

    Trigonometric correction / length unit Trigonometric correction / length unit Notice In the factory setting, the length unit is set to “m” (metres). It can be changed to “ft” (feet). Notice In the factory setting, the trigonometric correction is activated. If the elevation unit cannot stabilise freely (e.g.
  • Page 21 Trigonometric correction / length unit Activate trigonometric correction: Set DIP switch 2 to “ON”. Deactivate trigonometric correction: Set DIP switch 2 to “OFF”. ► Replace cover. ► Screw in the two screws (2). ► Press on both caps (1). LAP-TEQ Elevation...
  • Page 22: Cleaning And Care

    Cleaning and care Cleaning and care Danger! Risk of fatal injury from electric shock! ► Before working on the device, always disconnect the XLR cable to the display unit (power supply). Attention! Danger of damage to device! ► Do not immerse the device in water for cleaning, since water could penetrate and damage the electrical components.
  • Page 23: Malfunctions And Troubleshooting

    Laser not visible. Poor ambient Refer to information on conditions? ambient conditions in this manual. Cable too long? Use an XLR cable with a larger cross section. Measuring distance too If possible, reduce the large? measuring distance. LAP-TEQ Elevation...
  • Page 24: Service Centre

    If you cannot remedy the error yourself, contact our service department. Please note that unauthorised repairs will also void the warranty and can result in additional costs. Service centre TEQSAS GmbH Otto-Hahn-Straße 20a 50354 Hürth Germany Phone: +49 (0)2233 611-500 E-mail: service@teqsas.de...
  • Page 25: Observe Ambient Conditions

    Measurements through glass or plastic panes  Dirty laser beam exit opening  High temperature deviations: Before using in a very hot or cold environment, allow the device to adjust to the ambient temperature while in the transport case. LAP-TEQ Elevation...
  • Page 26: Storage

    Storage Storage ► Clean and dry all parts and store them in a clean and dry place. ► If you are not going to use or transport the device for an extended period, store it in the original package. Attention! Danger of damage to device! High temperatures can damage the device or permanently weaken the magnetic force of the magnets.
  • Page 27: Disposal

    Contact your local or municipal authority to find out more about where to dispose of used appliances. Separate disposal old appliances allows recycling or reuse of the materials. This prevents pollution of the environment from undesirable substances. LAP-TEQ Elevation...
  • Page 28: Technical Data

    Technical data Technical data LAP-TEQ Elevation Sensor Protection type IP40 Optic Spot optic Laser class 2 (<1 mW) Laser colour 635 nm (red) Measuring range 0.05 m to 40 m (in optimal conditions) Measuring tolerance range +/-1 mm (in optimal...
  • Page 29: Declaration Of Conformity

    Declaration of Conformity Declaration of Conformity LAP-TEQ Elevation...