EC Declaration of conformity Declaration pursuant to Directives 2004/108/EC(EMC); 2006/95/EC(LVD) Manufacturer: Automatismi Benincà SpA Address: Via Capitello, 45 - 36066 Sandrigo (VI) - Italy Declares that the product: Command central for 1 230 Vac motor, for sliding doors: CP.BULL 8OM is compliant with the conditions of the following EC Directives: •...
WIRE DIAGRAM Wire connections shown in Fig. 1 are described hereunder: Terminals Function Description CP.BULL8 OM: Input, 230Vac 50Hz (L-Phase/N-Neutral) Power supply CP.BULL8 OM 115: Input, 115Vac 60Hz (L-Phase/N-Neutral) Earth (compulsory) Connection antenna to the built-in receiver ANT/SHIELD Antenna (ANT-signal/SHIELD-screen). +12V COMMON Common for control inputs.
Page 6
COM (+12V) Common for limit switches. 12-0-12 Secondary Connection of secondary winding of 24V transformer Motor connection, 230Vac – single phase: M1/COM/M2 Motor M1-Phase/ COM-Common/ M2-Phase CAP/CAP Capacitor Connection to capacitor FLASH/FLASH Flashing light Connection to flashing light, 230Vac 40W max. TRASF Primary Connection to transformer primary winding...
Page 7
The intervention threshold of the anti-crashing device (Encoder) during braking is adjusted *. SEAR 0-99-(0%) 99:maximum sensitivity - 0: minimum sensitivity Activated only with SERL:ON Logic. The activation time of the service light is adjusted. 1-240-(60s) The force of the motor brake is adjusted. Ibra 0-99-(50%) 0: disabled braking - 1:minimum braking - 99: maximum braking...
Page 8
Check of photocells on PHOT O input is enabled or disabled. TST1 On: check is enabled. If check is not successful, no operation is enabled. (OFF) Off: AUX output can be preset as SCA, or by 2CH, SERL and TST2 logics. Check of photocells on PHOT C input is enabled or disabled.
Page 9
MAINTENANCE CYCLES (maci) This function enables to activate the maintenance request notice after a number of manoeuvres determined by the installer. To activate and select the number of manoeuvres, proceed as follows: Press button <PG>, the display will show OFF, which indicated that the function is disabled (default value). With the buttons <+>...
DIAGNOSTICS In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches, control and safety) can be displayed. One segment of the display is linked to each input. In the event of failure it switches on according to the following scheme. P.P.