Command Line Interface
D
perf.thresholdAlerts.counter.addAlert
Connectrix DS-24M2 User Guide
D-70
total value of the summed set counter is incremented. The items that
make up the summed sets are:
Physical Link Errors Summed Set
• Link Failures
• Sync Losses
• Signal Losses
• Protocol Errors
• Invalid Tx Words
• CRC Errors
• Frames Too Short
• Delimiter Errors
Link Sequence Counts Summed Set
• Link Resets Received
• Link Reset Sent
• OLS Received
• OLS Sent
Logical Link Errors Summed Set
• Discarded Frames
• Address ID Errors
• Class 2 Busied Frames
• Class 2 Rejected Frames
• Class 3 Discarded Frames
Syntax
addAlert name
Purpose
This command configures a new counter threshold alert and assigns
it a name. The new alert is assigned default settings which can then
be changed using the other counter threshold alert commands.
The default settings for a new counter threshold alert are:
Ports: None
Counter: None
Increment: 100
Interval: 60 minutes
State: Disabled