TABLE OF CONTENTS Safety instructions ............3 Intended use of the product ........4 Product description .............4 Instructions to the owner ..........5 Assembly instruction ...........5 Basic instruction for operation ........5 Program mode .............8 Extended usage information ........9 Settings mode .............9 10. Maintenance and Service ........12 11.
Safety instructions fi re hazard. Furthermore, this will reduce the lifetime of the dryer. Allow for sufficient cooling time of the dryer. Operator´s duty of care The distance to the object that is to be dried must be suf- ficient. Otherwise there is risk for fire or explosion! The IRT Siemens Leading Edge Protection Dryer is Keep all flammable materials in a sufficient distance designed and built after a hazard assessment was con-...
Product description Fire and explosion. Do not store, prepare or use solvent-containing materials The IRT Siemens Leading Edge Protection Dryer is a within a 5 m/16 feet radius of the mobile dryer. Flam- maneuverable infrared dryer. mable materials should not be placed close to a drying device in use.
Instructions to the owner Basic instruction for operation The owner of the dryer must produce clear operating Move the dryer to the site where you want to use it. This instructions, adapted to local site conditions, and make can only be done from the shorter side of the undercar- these available to all users who have to observe these riage with help of a fork lift or by pushing or pulling in operating instructions.
of distance sensors are disturbed by the infrared light. Note the lights are only an aid to find the right position towards the object it is possible to start the IR lamps although the lights are not green. Start of the fully automatic IR program. Infrared lamps turn off automatically after the drying period ends.
Page 7
Program mode This mode is for your everyday use. It helps you run the dry- er with pre-installed programs and edit program settings. To enter the program mode, turn the main switch on When you start the dryer, an information screen will appear for two seconds.
Program Mode – General rules for navigation in the software – The display shows software defined options in the bottom corner fields. – To adjust the values, use the arrow keys. – To move to previous display without saving, press cancel. Basic navigation There are 15 predefined programs.
Extended usage information Settings Mode Temperature control (OPTION) Log In The dryer is equipped with an automatic temperature To enter the settings mode you first have to ”log in”. Press control. This enables optimum drying/curing results both arrow keys as you turn the main switch on. The within the shortest possible time.
Page 10
Settings 9.4.3 3 Process Alarm Use the up and down arrow keys to set whether the available in alarm is active or not. Press select to confirm. Overview Basic Advanced 9.4.4 4 Temp. Unit 9.4.1 1 Select Language °C and °F appear on the screen. Use the up and down 9.4.2 2 Power Mode arrow keys to select the correct temperature unit.
Page 11
9.4.14 36 Advanced Pin code Test 4: Cassette IR Test The IR cassette lamps (output I) light up. Check that all To change the code to your personal choice, use the up and down arrow keys to change the first digit, press the IR lamps are lit.
To alter the values for P and I full understanding of PID controllers is needed. If this knowledge is not at site, please contact Hedson Technologies AB if this needs to be adjusted. 9.4.26 54 Output 2 Scale Possibility to control the level of power on output 2 from 0-100% compared to output 1.
Page 13
Yearly Attach lamp Plan to change the air filter approx. once per year. You Keep the protection paper around the lamp until the fit- will get a message in the software when it is time to ting is completed. change. When starting up the dryer you will get an indi- cation on how much of the filter time that is used.
Regular safety inspection Reflector E790 Gold foil 102696 Reflector E790 Net 193646 Contact Hedson Technologie's customer service depart- Reflector E790 Glass 716238 ment if you have any further questions. Printed Circuit Board (PCB) 750321 E-mail support.his@hedson.com...
Page 15
12.1 Regular safety inspection form Device type Serial No. Inspection step Not OK Verification Remark Name plate Plate with load capacity Plate with supply pressure Lifting/lowering tag All supporting screws are tight Secure scissor pins State of pneumatic hoses Safety valve set to 6.5 bar operating pressure Mains pressure manometer Pmax = 8 bar...
According to testing institutes and according to the machinery directive the IRT products in this manual are not defined as machines, wherefore the machinery directive reference cannot be included in this declaration. In accordance with EN 17050-1:2010 Hedson Technologies AB Box 1530 SE 462 28 Vänersborg...
14. Pneumatic and Electrical diagrams Pneumatic diagram for Hercules Working platform, see appendix 1: 761-054_PNTS-77 Electrical diagram for IRT Siemens Leading Edge Protection Dryer equipment is found in the appendix 2. 15. Weights and Dimensions The overall weight is 665 kg Dimensions as below: For other technical specifications regarding Herkules working platform, see appendix 1: 761-054_PNTS-77.
16. Trouble shooting Malfunction Possible fault Rectification Some lamps do not Defective lamp Change lamp light up One supply phase has failed Check fuses Incorrect connection Check electrical connections in wiring diagram No lamps light up or Short circuit/damaged cable Check fuses.