  • Page 1 Isolite 3 Training © 2018 Zyris, Inc. Isolite is a trademark of Zyris, Inc. All rights reserved. MK9003-066-A1...
  • Page 2 Thank you for adding Isolite 3 to your practice...
  • Page 3 What to expect today WE’LL COVER THE FOLLOWING TOPICS Overview of the Isolite 3 Installation of the Isolite 3 Getting started How to select and place mouthpieces Cleaning and maintenance...
  • Page 4 ISOLITE 3 PREDICTABILITY The Isolite 3 removes many of the negative variables that can impact treatment including soft tissue interference and low visibility. PRODUCTIVITY Continuous hands-free suction evacuates water, saliva and debris for unsurpassed moisture control. RISK MANAGEMENT The Isolite 3 shields soft tissue.
  • Page 5 QUALITY Made of Liquidmetal ® and manufactured in the U.S.A., the Isolite 3 is lightweight but mighty and made for years of use. EASE Unlike rubber dam placement, the Isolite 3 can be placed, removed and placed again in seconds.
  • Page 6 INTELLIGENT POWER VACUUM BASE The Power Vacuum Base can be set to provide suction for the Isolite 3 by itself, the Isolite 3 and an accessory, an accessory only or completely turned off when cleaning and...
  • Page 7: Installation

    Installation...
  • Page 8: What's Included In The Box

    What’s Included in the Box Instructions for Use Accessory connector Quick Start Guide Direct-to-chair power adapter Control Head with integrated hose Isolite 3 power adapter Power Vacuum Base O-ring lubricant Six (6) Vacuum Light Pipes Two (2) Barb adapters Cleaning tip adapter...
  • Page 9 Connecting the ISOLITE 3 STEP 1 Attach the end of the vacuum connector hose to an available High Volume Evacuation (HVE) suction port.
  • Page 10 Connecting the ISOLITE 3 [ STEP 1a ] Alternate method if no suction ports are available...
  • Page 11 Connecting the ISOLITE 3 STEP 2 Place the Control Head Hose on an empty slot on the tool bar, as shown. Please contact your dealer or chair manufacturer if you do not have an opening in your tool bar.
  • Page 12 Connecting the ISOLITE 3 STEP 3 Connect the Power Vacuum Base onto the vacuum connector hose.
  • Page 13 Connecting the ISOLITE 3 STEP 4 Plug in power adapter to standard 120V power source. For direct-to-chair connection cable instructions, refer to the Instructions For Use.
  • Page 14 Connecting the ISOLITE 3 STEP 5 Plug in power adapter connector to the top of the Power Vacuum Base.
  • Page 15 Connecting the ISOLITE 3 STEP 6 Confirm light on Power Vacuum Base is solid blue. Refer to “Using the Power Vacuum Base LED Indicator” section in the Instructions For Use if light is not solid blue.
  • Page 16 Connecting the ISOLITE 3 STEP 7 Rotate the suction selection dial to desired setting. Allow up to 30 seconds for blue light to appear.
  • Page 17 Anatomy of the ISOLITE 3...
  • Page 18 Anatomy of White & Amber the ISOLITE 3 Light Setting Integrated LEDs Color Preview Setting The Isolite 3 control head is integrated with the hose. Control Head & Hose Integration The only detachable parts Dual Level Vacuum Control are the Vacuum Light Pipe and the dual lever vacuum controls.
  • Page 19 Turning the Light On and Off Press the top button once to turn the system light on. Press the top button and hold for 1 second to turn the system off.
  • Page 20 Understanding the Light Settings Tap the Power button once to enable the Low light setting. Tap the Power button a second time to enable the Medium light setting. Tap the Power button a third time to enable the High light setting.
  • Page 21 Toggle Between White and Amber Press the White / Amber button once to use white light. Press the button again to toggle to the cure-safe Amber light mode.
  • Page 22 Using the Power Vacuum Base To use the Isolite 3, turn the control dial on the PVB to the “9 o’clock” position. This is the most common setting on the PVB for most practices.
  • Page 23 Using the Power Vacuum Base Turn the control dial to the “12 o’clock” position to allow suction only through the accessory line. In this mode, the Isolite 3 will not have any suction.
  • Page 24 Turn the control dial to the “6 o’clock” position to allow suction to pass through the Isolite 3 and the accessory port. Choose this option when you want to use both the Isolite 3 and another accessory attached to an HVE.
  • Page 25 Using the Power Vacuum Base Turn the control dial to the “3 o’clock” position to prevent any suction from passing through the PVB. Choose this option when disconnecting the hose from the PVB.
  • Page 26 Removing the Selection Dial To remove the selection dial, rotate it clockwise past the “Off” indicator. The dial will stop rotating, lift up on the selection dial to remove it. To replace, insert the selection dial into the PVB and rotate counter-clockwise.
  • Page 27 Connecting and Removing the Vacuum Light Pipe The Vacuum Light Pipe on the Isolite 3 slides up and down at a slight angle. When removing a Vacuum Light Pipe for cleaning, press the Easy Release Latch and then lift up on the Vacuum Light Pipe.
  • Page 28 Using the Dual Level Controls Dual Vacuum Levers adjust suction intensity in both the upper and lower quadrants. To adjust, rotate the left and right Vacuum Levers to the desired suction intensity for each quadrant. To shut off suction, rotate the levers to the most downward position.
  • Page 29 Mouthpieces...
  • Page 30 Anatomy of Cheek Shield the Mouthpiece Flexible Isthmus Each mouthpiece is Dual Vacuum Channels constructed of polymeric Illumination Path material that is softer than gingival tissue to ensure Tongue and Throat Shield patient comfort. Integrated Bite Block The single-use mouthpiece with Rear Evacuation Channel helps manage infection control, foreign body...
  • Page 31 A Size for Every Patient Mouthpieces come in six sizes designed to fit the widest range of patients, giving you easy and effective isolation for patients of all ages, from pediatric to geriatric.
  • Page 32 Sizing & Attaching Mouthpieces...
  • Page 33 Mouthpiece Sizing Instruct your patient to open as wide as they can comfortably. Use your fingers to measure their interincisal opening or use calipers or another measuring device. Once you have determined a size, open the Mouthpiece bag in front of your patient to assure them it has never been used before.
  • Page 34 Attaching the Mouthpiece Lubricate the inside surface of the Mouthpiece sleeve with water.
  • Page 35 Attaching the Mouthpiece Slide the Mouthpiece onto the control head until the two locking barbs engage the matching holes on the Mouthpiece.
  • Page 36 Preparing the Mouthpiece for Placement Moisten the back of the Mouthpiece with water spray.
  • Page 37 Preparing the Mouthpiece for Placement Moisten your patient’s lips using lip balm. Moistening the Mouthpiece and lips will aid in easily sliding the Mouthpiece into your patient’s mouth.
  • Page 38 Placing the Mouthpiece...
  • Page 39 Mouthpiece Placement Hold the control head gently between index finger and thumb. Fold the cheek shield onto the tongue retractor. Use two hands when placing the Mouthpiece.
  • Page 40 Mouthpiece Placement Gently slide the folded Mouthpiece into the buccal vestibule on the side of the mouth to receive treatment, staying buccal to the mandible.
  • Page 41 Mouthpiece Placement Draw the bite block across the mouth onto the occlusal surface of the teeth opposite the side to receive treatment, distal to the mandibular cuspid. Instruct your patient to bite down gently.
  • Page 42 Mouthpiece Placement Place the cheek shield into the cheek and tuck the isthmus onto the retromolar pad.
  • Page 43 Single-Use The mouthpieces for the Isolite 3 system are single-use only. No risk of cross-contamination Less stress for you Increased patient confidence No time spent cleaning or tracking autoclave cycles and number of times used...
  • Page 44: Cleaning And Maintenance

    Cleaning & Maintenance...
  • Page 45 Disinfecting the Control Head & Hose Following the manufacturer’s instructions for contact time, use an intermediate level disinfectant wipe with a claim to inactivate Mycobacterium tuberculosis. Otherwise, use a hospital-grade disinfectant on all surfaces of the Control Head and the Control Head Hose to remove all visible biomatter and debris.
  • Page 46 Sterilizing the Vacuum Light Pipe Zyris recommends sterilization of the Isolite 3 Vacuum Light Pipe between each patient. Remove biomatter and other debris from the suction channels using a brush with a neutral pH (6.5-7.5) enzymatic cleaning solution. Do not use solution to hold parts.
  • Page 47 132 ºC / 270 ºF 15 min 15 min Prevacuum 132 ºC / 270 ºF 4 min 20 min Prevacuum 134 ºC / 273 ºF 3 min 20 min Please refer to the Instructions for Use that are included with your Isolite 3.
  • Page 48 Disinfect the hose Isolite 3 has a new attachment that connects directly to disinfection/cleaning canisters, making line cleaning simple and efficient.
  • Page 49: Additional Resources

    The printed Quick Start Guide and members who join your practice and Instructions for Use included with provide additional training for existing the Isolite 3 can be used to train staff to maintain their proficiency. new team members. MOUTHPIECE QSG...
  • Page 50 INTELLIGENT POWER VACUUM BASE The Power Vacuum Base can be set to provide suction for the Isolite 3, the Isolite 3 and an accessory, an accessory only or completely turned off when cleaning and sterilization are being performed.
  • Page 51 Q&A...