Summary of Contents for Wilo Wilo-DrainLift KH 32-0,4
Page 1
Wilo-DrainLift KH 32-0,4 Einbau- und Betriebsanleitung Beépítési és üzemeltetési utasítás ł Installation and operating instructions Instalacja i instrukcje obs Notice de montage et de mise en service Návod k montᡠz í a obsluze Onderhouds- en bedieningsvoorschriften Οδηγίες εγκατάστασης και λειτουργίας...
Page 6
CE-Konformitäts- EC declaration of Déclaration de conformité CE erklärung conformity Hiermit erklären wir, daß die- We hereby declare that this Par la présente, nous ses Aggregat folgenden ein- unit complies with the déclarons que cet agrégat sitisfait aux schlägigen Bestimmungen following relevant provisions: entspricht: dispositions suivantes:...
Page 7
ˇ unu temin ederiz: AB-Makina Standartlari 89/392/EWG i.d.F., 91/368/EWG, 93/44/EWG, 93/68/EWG Elektromanyetik Uyumluluk WILO AG 89/336/EWG i.d.F., Nortkirchenstraße 100 92/31/EWG, 93/68/EWG Quality Management 44263 Dortmund · Germany Özellikle kullaní ´ lan Normlar EN 809, EN 50 081-1, EN 50 082-1, EN 50 081-2, EN 50 082-2.
– Max. flow medium Repairs on this unit should only be carried out by an temperature: 35 °C expert or by Wilo customer services. – Voltage/frequency: 1~230 V, 50 Hz The unit’s functions are all automatic. It is not neces- –...
ENGLISH indicated by the symbol: qualified specialists who have carefully studied these instructions. In principle, work on the unit may only be carried out after it has been brought to a stand- still. 2.6 Unauthorised alterations and manufacture Safety precautions warning of danger due to electri- of spare parts city are indicated by the symbol: Alterations to the pump or installation may only be...
Page 11
ENGLISH The motor coil is protected by an overload safety The unused inlet opening must be locked with the device which automatically switches off the motor if cowl provided: exposed to an above-average level of stress. After – Push the pressure ring on to the cowl –...
ENGLISH (fig. 2, pos. 9) should be removed from the ventila- – Remove covering cap (fig. 2, pos. 8) using the tion and the vent connection (fig. 3, pos. 2, inner- tommy bar (fig. 2, pos. Z) and pressing the 3 snap Ø...
Dismantle motor and clean. If necessary, contact noises when rotating customer services. If the fault cannot be remedied, please contact your local plumbing and heating specialist or Wilo customer services. Subject to technical alterations!
Need help?
Do you have a question about the Wilo-DrainLift KH 32-0,4 and is the answer not in the manual?
Questions and answers