Operation
Danger of injury caused by im-
plosion.
Damage to the glass lid can cause
implosion.
Do not under any circumstances use
the drawer if the glass lid is dam-
aged.
Malfunction due to dirty and/or
covered sensor controls.
The sensor controls do not react or
unintentional switching procedures
result, perhaps even the automatic
deactivation of the drawer.
Keep the sensor controls and indic-
ators clean.
Do not place anything over the
sensor controls or indicators.
Damage caused by liquids.
Liquid getting into the vacuum pump
air intake valve during a vacuuming
process can result in damage to the
vacuum pump.
Fill the vacuum sealing bag with li-
quid to a maximum of ¹/₃.
22

Vacuuming and sealing bags

 Fill the vacuum sealing bag.
 Open the drawer and the glass lid.
 Place the vacuum sealing bag in the
vacuum chamber so that the open
end of the bag lies across the sealing
bar. Ensure that the edge of the bag
is positioned centrally and crease-
free on the sealing bar.
 If a bag is too small and slips into the
vacuum chamber, place the vacuum
sealing bag support under it.
 Switch the drawer on with the
 sensor control.
The  and  sensor controls light up.
 Touch the  sensor control re-
peatedly until the segment for the re-
quired vacuum setting lights up.
 Touch the  sensor control re-
peatedly until the segment for the re-
quired sealing level lights up.
 Close the glass lid and press it down
lightly.
The vacuuming process will start.
The following occurrences during the
process are normal and do not indic-
ate a functional or appliance fault:
– The bag inflates, before enveloping
the food being vacuum-sealed.
– Bubbles form in the liquid, creating
the impression that it is boiling.