Centripro S10020 control box, Circuit board "run" light is on showing float switch works, but pump does not run, (runs OK with the manual switch) - need troubleshooting assistance
Summary of Contents for Xylem Goulds CentriPro Series
Page 1
Well Pump Langley Service Aldergrove, Cloverdale, Fort Langley, Glen Valley, Langley Township, Surrey, Walnut Grove, White Rock, Tsawwassen, Ladner, Delta, Richmond, and Burnaby Phone: 1-604-670-3033 Service Manual SUBMERSIBLE PUMPS • JET PUMPS GSSERVICE R4...
Safety Warnings TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL AND ON PUMP. THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP. This is a SAFETY ALERT SYMBOL.
Page 4
Important notice: Read safety instructions before proceeding with any wiring. All electrical work must be performed by WARNING a qualified technician. Always follow the National Electrical Code (NEC), or the Canadian Electri- cal Code, as well as all local, state and provincial codes. Code questions should be directed to your local electrical inspector.
Install wire and ground according to DANGER the National Electrical Code (NEC), or the Canadian Electrical Code, as well as all local, state and provincial codes. Install an all leg disconnect switch where WARNING required by code. The electrical supply voltage and phase WARNING must match all equipment requirements.
Page 6
Two-Wire System Illustrated RULE OF THUMB 1. Use same size or larger pipe as discharge on pump. 2. Always use a check valve for every 200 ft. of vertical pipe. To House Piping Protected Power Supply Disconnect Switch Shut-off Valve Union Pressure Switch...
Page 7
Motor Cooling, Temperature and Time Ratings All 4 inch CentriPro motors may be operated continuously in water up to 86º F. Optimum service life will be attained by maintaining a minimum flow rate past the motor of .25 feet per second.
Page 8
Minimum Flow Rates for Proper Motor Cooling 3.75" Dia. CP = FE = CP = Well or 4" CP or 5.5" Dia. 5.38" Dia. 7.52" Dia. Sleeve FE Motor 6" CP 6" FE 8" CP Diameter .25'/sec Motor Motor Motor (inches) .5'/sec.
Pump Motor Not Running Probable Cause Recommended Action 1. Motor thermal protector 1. Allow motor to cool, ther- tripped mal protector will automati- cally reset a. Incorrect control box b. Incorrect or faulty a – e. Have a qualified elec- electrical connections trician inspect and repair, c.
Page 10
Little or No Liquid Delivered by Pump Probable Cause Recommended Action 1. Faulty or incorrectly installed 1. Inspect check valve, repair check valve as required 2. Pump air bound 2. Successively start and stop pump until flow is delivered 3. Lift too high for pump 3.
Page 11
Pump Will Not Start or Run. . . Probable Cause Recommended Action 1. No power 1. Check for tripped circuit breaker 2. Incorrect voltage 2. Check with voltmeter 3. Defective pressure switch 3. Inspect switch points and wires 4. Loose wire connections 4.
Page 12
The Amprobe is a multi-range, combination ammeter and voltmeter. Voltmeter Scales: 150 Volts 600 Volts Ammeter Scales: 5 Amps 40 Amps 15 Amps 100 Amps 1. When used as an ammeter, the tongs are placed around the wire being measured with the rotary scale on the 100 amp range.
Page 13
The Ohmmeter is used for measuring the electrical resistance of a wire circuit. The unit of measurement is called an Ohm. 1. The knob at the bottom of the Ohmmeter is adjustable through six ranges: = R x 1 If your ohmmeter = R x 10 is digital readout = R x 100...
Page 14
Megger This instrument is used to measure insulation resistance to ground. It consists of a crank- turned magneto, on the side of the case, and will give very close readings calibrated di- rectly in ohms. It is cranked at a moderate rate of speed, approximately 120 rpm, until the pointer reaches a steady deflection.
Page 15
WARNING! Open master breaker and disconnect all leads from starter to avoid damage to meter or electric shock hazard. Connect the ohmmeter leads as shown above. Coil with Ohmmeter 1. Set R x 1000. 2. Connect leads as shown. 3. Reading: Should register some value, Approx.
Page 16
Voltage Relay CONTROL BOXES (CENTRIPRO OR F.E.) Checking Relay with Ohmmeter A. Voltage Relay Tests Step 1, Coil Test 1. Meter setting: R x 1,000. 2. Connections: #2 & #5. 3. Correct meter readings: For 115 Volt Boxes: .7 – 1.8 (700 to 1,800 ohms). For 230 Volt Boxes 4.5 –...
Page 17
Voltage Relay CONTROL BOXES (CENTRIPRO OR F.E.) Step 2, Contact Test 1. Meter setting: R x 1. 2. Connections: #1 and #2. 3. Correct meter reading: Zero for all models. B. F.E. Blue Relay - Solid State ⁄ – 1 HP QD Control Boxes Used from 1994 until present time: Step 1, Triac Test 1.
Checkout Procedure for Magnetic and Other Contactors Contactor Coil Test (Disconnect lead from one side of coil) 1. Meter setting: R X 100 2. Connections: Coil terminals 3. Correct meter reading: 180 to 1,400 ohms Contactor Contact Test 1. Meter Setting: R X 1 2.
Page 19
For 1½ HP (and Larger) Control Box 1. Set Ohmmeter at “R x 1” 2. Connect the Ohmmeter leads to Terminal #1 and #3 on each Overload Protector. 3. Reading should be not more than 0.5 Ohms maximum on the scale. CSCR or Mag.
Page 20
Capacitor with Ohmmeter CAUTION Discharge the capacitor before making this check. (A screwdriver can be used to make contact between capacitor’s posts.) 1. Disconnect leads to capacitor post. 2. Setting: R x 1,000 3. Connect ohmmeter leads to capacitor posts. 4.
Page 21
1. Set R x 1. 2. Connect leads as shown. 3. Reading: Should register zero. What It Means – Zero reading indicates fuse OK. Infinity (∞) reading indicates bad fuse.
Page 22
To Check Voltage with “Q.D.” Type Control Box 1. Remove cover to break all motor connections. CAUTION and L are still connected to power. 2. To check VOLTAGE: Use voltmeter on L1 and L2 as shown. 3. When checking voltage, all other major electrical appliances (that could be in use at the same time) should be running.
Page 24
Checking Voltage at Fused Disconnect and Magnetic Starter WARNING! Power is ON during voltage checking. 1. To check voltage: Use voltmeter on L1, L2 and L3 in sequence. Check should be made at four locations. Step 1 Checking incoming power supply. Step 2 Checking fuses.
Page 26
WARNING! Power is ON during current checking. Using Amprobe 1. Set scale to highest amp range. 2. Connect amprobe around lead as shown. 3. Rotate scale to proper range and read value. 4. Compare value with table. What It Means – Currents above these values indicate system problems.
Page 27
Service Factor Amps with QD (½ - 1 HP) or CSCR (1.5 HP & Larger) Control Boxes ① 4" F.E. F.E. 1Ø 3-Wire 3-Wire 2-Wire 2-Wire HP Volts Yel Black Red Yel Black Red Black Black ½ 115 12.6 12.6 0 12.0 12.0 12.0 ½...
Page 28
Magnetic Starter and Pressure Switch To Fused Disconnect Or Circuit Breaker 3Ø Magnetic Starter 3 Phase Starter T 1 T 2 T 3 Ground To Pump Motor Pressure Switch Requires class 10 quick trip “k-heaters” (overloads), or adjustable class 10 overloads such as ESP100, ESP 200 NOTE: Check to be sure proper selection of...
Page 29
To Fused Disconnect Or Circuit Breaker 3Ø Magnetic Starter Line Load Ground To Pump Motor Pressure Switch RULE OF THUMB Check that starter has ground.
Page 30
Magnetic Starter, Pressure Switch and Liquid Level Control To Fused Disconnect Or Circuit Breaker 3Ø Magnetic Starter 3 Phase Starter T 1 T 2 T 3 Input Power (As Required By Level Control) To Pump Motor Ground Level Control Pressure Switch Lower Upper Ground...
Page 31
To Fused Disconnect Or Circuit Breaker 3Ø Input Power (As Required By Level Control) Ground Lower Upper Electrode Magnetic Starter Line To Pump Motor Load Ground Pressure Switch...
Page 32
2-Wire Pump Wiring Diagram with PumpSaver Plus 233P...
Page 33
Standard 3-Wire Control Box Wiring Diagram with PumpSaver Plus 233P...
Page 34
Checking Cable and Splice 1. Submerge cable and splice in steel barrel of water with both ends out of water. 2. Set ohmmeter selector on RX100K and adjust needle to zero (0) by clipping ohmmeter leads together. 3. After adjusting ohmmeter, clip one ohmmeter lead to barrel and the other to each cable lead individually, as shown.
Page 35
Checking Cable and Splice Test O H M S Ohmmeter Set at RX 100K Z E R O O H M S R X 1 0 0 R X 1 0 0 0 R X 1 0 R X 1 0 K RX 100K R X 1 Attach this Lead...
Page 36
1. Set the scale lever to R x 100K and adjust to 0. CAUTION Open (turn off) master breaker and disconnect all leads from control box or pressure switch (Q-D type control, remove lid) to avoid damage to meter or electric shock hazard.
Page 37
Normal Ohm and Megohm Values (Insulation Resistance) Between All Leads and Ground Insulation resistance does not vary with rating. All motors of all HP, voltage and phase rating have similar values of insulation resistance. Condition of Motor and Leads Ohms Megohm Value Value...
Page 38
1. Set the scale lever to R x 1 for values under 10 ohms. For values over 10 ohms, set the scale lever to R x 10. Zero balance the ohmmeter as described earlier. WARNING! Open master breaker and disconnect all leads from starter to avoid damage to meter or electric shock hazard.
Page 41
2-Wire and 3-Wire – Fuse and Circuit Breaker Amps GENERATION I & II - Fuse or Circuit Breaker Amps 2011 Order No. Standard Dual Element Circuit Type CentriPro Fuse Time Delay Breaker M05421 M05422 Wire M07422 0.75 (PSC) M10422 M15422 M05411 3-Wire M05412...
Page 42
3-Wire, 1Ø, 4" Motors - Electrical Data, 60 Hz, 3450 RPM Order No. Volts Type CentriPro M05411 3-Wire M05412 with Q.D. Cap. Start M07412 0.75 M10412 M05412 M07412 0.75 3-Wire with M10412 CSCR (CR) Magnetic M15412 Contactor (MC) M20412 1.25 Control Box M30412 1.15...
Page 50
Motor Lead Lengths – 3Ø Motors – Based on S.F. Amps, 30º C Ambient and 5% Voltage Drop 60º C and 75º C Insulation - AWG Copper Wire Size Motor Rating Volts 0.37 1000 1595 0.75 0.55 1074 0.75 10.9 12.0 18.3 20.2...
Page 52
Units with 1Ø Input and 3Ø Output (Motors) Maximum Cable Lengths in Feet to Limit Voltage Drop to 5% for 230 V Systems ➄ Copper Wire Size 75ºC Insulation Exposed to a Maxi- mum of 50ºC (122ºF) Ambient Temperature ⑥ Service Entrance to Controller Controller Motor Input...
Page 58
Franklin Electric 3Ø, 6" and 8", 1.15 S.F. Motors Motor Franklin Rated Input Volts Diameter Order No. Amps S10978 17.5 S10971 S10972 S11978 25.1 S11971 21.8 S11972 10.9 S11979 S12978 32.7 S12971 28.4 S12972 14.2 S12979 11.4 S13978 47.8 S13971 41.6 S13972 20.8...
Page 59
Franklin Electric 3Ø, 6" and 8", 1.15 S.F. Motors — Continued Service Factor Locked Rotor Amps Amps Resistance .77-.93 17.6 1.0-1.2 3.9-4.8 28.3 .43-.53 24.6 .64-.78 12.3 2.4-2.9 3.7-4.6 .37-.45 32.2 .47-.57 16.1 1.9-2.4 12.9 3.0-3.7 54.4 .24-.29 47.4 .28-.35 23.7 1.1-1.4 1.8-2.3...
Page 60
1. To check: Shut off power supply and drain system to “0” pressure. 2. Air pre-charge in tank should be 2 psi less than the cut-in pressure of the pressure switch. Example: If pressure switch setting is 30-50 psi, tank should be pre-charged with 28 lbs.
Page 61
Tank Volumes ① Drawdown in Gals. at System Maximum Total Operating Pressure Range of Model Volume Drawdown 18/40 28/50 38/60 (Gals.) Vol. (Gals.) PSIG PSIG PSIG V15P V25P V45P 13.9 V45B 13.9 13.9 V60B 19.9 12.1 19.9 12.1 25.9 10.4 13.9 V80EX 25.9 10.4...
Shallow Well System illustrated is a Convertible jet pump with a shallow well adapter and a pressure tank. RULES OF THUMB • All jet pumps should be located at the highest point in the suction side of the system. • (Distance from well head to pump) If offset is greater than 20' .
Page 63
Deep Well Packer and twin pipe systems Improper Installations • Trap air • Hard to prime TRAPS AIR Proper Installations • Easy to prime...
Page 64
Jet Pump Disassembly . . . 1. Turn off power to motor. Disconnect service wires from pressure switch. 2. Drain system to relieve pressure. 3. Disconnect motor cord from pressure switch when used. 4. Remove casing bolts. If pump is mounted on top of tank, remove bolt holding motor adapter to mounting pad.
Page 66
Jet Pump Reassembly . . . 1. Be sure that recess for seal seat and surface where guide vane mounts on motor adapter are entirely free of all scale and dirt. 2. Clean motor shaft. 3. Apply film of light oil, such as vegetable oil, to the recess of the motor adapter and the neoprene bushing before installing the new seal seat.
Page 67
8. Replace diaphragm gasket with opening in the upper position. 9. Replace guide vane seal ring on guide vane hub. 10. Make sure all gasket surfaces are clean. Replace pump casing. 11. Tighten casing bolts alternately and evenly. 12. After reassembling pump, check to be sure impeller rotates freely.
An amprobe, ohmmeter and vacuum pressure gauge are essential for properly checking a system. Use of the amprobe and ohmmeter are explained in Amprobe/ Ohmmeter Instructions. Use of the compound vacuum pressure gauge is explained in Checking Suction Lift. Find the basic problem for which numerous symptoms and possible solutions are given for each.
Page 69
Pump Runs But . . . Little or no water delivered Problem Recommended Action 1. Pump or pipes not Fill pump completely with completely primed. water through priming opening (reprime pump). a. Deep Well system Control valve must be set properly or system will not pump.
Page 70
Pump Runs But . . . Problem Recommended Action 4. Jet assembly plugged. A. Shallow Well system Clean if necessary (Insert wire through ½" plug in shallow well adapter.) b. Deep Well system Pull jet assembly and clean. 5. Punctured diaphragm Disconnect the tubing and in air control.
Page 71
Pump Runs But . . . Pump starts and stops too often . . . Problem Recommended Action 1. Leaks in piping system. Pressurize piping system and inspect. Repair or replace. 2. Faulty pressure switch. Check contact points. Adjust or replace switch. 3.
Pump Runs But . . . Pumps water, but does not develop 40 lbs. tank pressure. . . Problem Recommended Action 1. Leaks in well piping or Pressurize piping system discharge pipe. and inspect. 2. Jet or screen on foot valve Clean if necessary.
Page 73
Pump Runs But . . . Pump develops 40 lbs. pressure, but switch does not cut out . . . Problem Recommended Action 1. Pressure switch incorrectly See Switch Adjustment. set. 2. Tubing or fittings between Remove switch tubing and/or switch and pump plugged.
Page 74
How to Use Volt-Ammeter CAUTION Power is ON during voltage checking. 1. Attach leads to volt-ammeter and select proper voltage scale for voltage to be tested. 2. Place leads in A position to test for presence of incoming voltage. • Voltage should be within + 10% of the design voltage specified on the motor nameplate in A, B and C test positions.
Page 75
WARNING! Power is ON during voltage checking. Using Amprobe 1. Set scale to highest amp range. 2. Connect amprobe around lead as shown. 3. Rotate scale to proper range and read value. 4. Compare value with table. What It Means – Currents above these values indicate system problems.
Page 76
CAUTION Power is ON during amperage testing.
Page 77
CAUTION Use ohmmeter only with POWER OFF. Power supply OFF. Disconnect motor leads (L1 and L2). On dual-voltage motors, motor must be wired 230V for the checks listed below and illustrated on the page indicated for each check. Rewire for 230V if necessary. CHECK: Page a.
Page 78
Ground Check CAUTION Disconnect Power Source before checking. a. Set ohmmeter to R x 1,000. b. Attach one probe to ground screw and touch other probe to all terminals on terminal board, switch, capacitor and protector – any ohmmeter reading indicates ground.
Page 79
Winding Continuity - A.O. Smith / Century Motor CAUTION Disconnect Power Source before checking. 1. Terminal board connected for 230 V. 2. Set ohmmeter to R x 1, adjust to 0. 3. Slip a heavy piece of paper between motor switch points, discharge the capacitor and take the following ohm readings: a.
Page 80
Ohmmeter tests on the new style terminal board with the quick-change voltage selector switch, see picture on pg. 76 (Black plastic part with 2 wires in it) is simplified if your ohmmeter is equipped with the sharp, pointed probes rather than alligator clips. With the voltage change plug on the 230 volt terminal the Black wire in the plug is positioned on Terminal “A”.
Page 81
Winding Continuity - US Motor CAUTION Disconnect Power Source before checking. 1. Terminal board connected for 230 V. 2. Set ohmmeter to R x 1, adjust to 0 (NOTE: Digital meters are typically used, the reading on this equipment should be showing OL or infinity). 3.
Page 82
Contact Points (Start Switch) CAUTION Disconnect Power Source before checking. 1. Set ohmmeter to R x 1, adjust to 0. 2. Remove leads from start switch. 3. Attach ohmmeter leads to each side of switch – reading should be 0. 4.
Page 83
Motor Overload Protector - US Motor CAUTION Disconnect Power Source before checking. 1. Set ohmmeter to R x 1, adjust to 0 (NOTE: Digital meters are typically used, the reading on this equipment should be showing OL or infinity) 2. Dissconnect the Overload protector leads 3.
Page 86
Capacitor CAUTION Disconnect Power Source before checking. IMPORTANT Discharge capacitor by touching the two terminals with the blade of an insulated handle screwdriver. 1. Set ohmmeter to R x 1,000, adjust to 0. 2. Disconnect leads on capacitor. 3. Attach ohmmeter leads to each terminal. Needle should swing to right and drift slowly to left.
Page 87
Adjust in proper Sequence: 1. CUT-IN: Turn range nut down for higher cut-in pressure, or up for lower cut-in. 2. CUT-OUT: Turn differential nut down for higher cut-out pressure, or up for lower cut-out. Note: Adjustment to range (cut-in) nut will also change cut-out pressure.
Page 88
A vacuum gauge indicates total suction lift (vertical lift + friction loss = total lift) in inches of mercury. 1" on the gauge = 1.13 ft. of total suction lift (based on pump located at sea level). RULE OF THUMB Practical suction lift at sea level is 25 ft.
Page 89
Compound Vacuum Pressure Gauge This gauge will show the pressure or vacuum at any position in a pump or system where it is installed. A reading of 20" on a vacuum gauge placed on the suction side of the pump would tell you that you have a vacuum or suction lift of 22.6 ft.
Page 90
When pump is first started or under maximum flow condition, pressure control should be immediately adjusted to the pressure corresponding to H.P. and jet assembly used. See rating tables in catalog for proper pressure setting. 1. Turn left to reduce pressure. 2.
Page 91
Correct rotation is a must on all 3Ø installations. Rotation can be checked by one of these three ways: Visual 1 1. Connect 3 motor leads to starter, run unit at open discharge. 2. Switch any 2 leads and again run unit at open discharge.
Page 92
Supply Starter Motor Supply 1st Hookup 2nd Hookup 3rd Hookup Starter Starter Starter Motor For the best protection, we recommend no more than a 5% current deviation from average current. Current readings in amps should be checked on each leg using the three possible hookups. CAUTION To prevent changing motor rotation, the motor leads should be reordered in the...
Page 93
Calculate percentage of current unbalance for all three hookups. Example: Hook Up 1 Hook Up 2 Hook Up 3 T 1 = 51 Amps T 3 = 50 Amps T 2 = 50 Amps T 2 = 46 Amps T 1 = 48 Amps T 3 = 49 Amps T 3 = 53 Amps T 2 = 52 Amps...
Page 94
A full 3Ø supply is recommended for all 3Ø motors, consisting of three individual transformers or one 3Ø transformer. “Open” delta or wye con- nections using only two transformers can be used, but are more likely to cause problems from current unbalance.
Page 96
Aquavar SOLO – Quick Installation Guide 1. Mount Drive (in a vertical position); • Must have 6” minimum clearance on all sides for proper cooling. 2. Connect Input Power Wire (Single Phase, 230V, Size Wire Ampacity for 75˚C Copper Wire) •...
Page 97
Aquavar SOLO – User Interface Board 1AS Controllers 3AS Controllers 1) Basic Drive Settings 5) Relay Output 9) Setpoint Select Input 2) Controller Status Indicator 6) Transducer Input 10) Display Mode Adjust 3) Setpoint and Parameter Adjust 7) Transducer Jumper 11) Status and Parameter Display 4) Run/Stop Indicator 8) Run/Stop Input...
Page 98
Aquavar ABII Quick Start Guide Installation Steps: 1. Install the Pump • Plumb suction and discharge of pump into piping. • Install a check valve on the suction side. • Locate the pump as near liquid source as possible. 2. Install the Pressure Transducer •...
Page 99
S-Drive Quick Start Up Guide Step 1: Mount drive on secure wall or support beam using 4 screws. Ensure drive is well ventilated. Leave at least 8” of free space around the controller for cooling. Plug conduit holes not used. Step 2: Measure site voltage phase-phase and phase-ground;...
Page 100
addresses & phone Company __________________________________________ Contact ___________________________________________ Address ___________________________________________ City _________________ State ________ Zip___________ Phone ____________________ Fax _____________________ Company __________________________________________ Contact ___________________________________________ Address ___________________________________________ City _________________ State ________ Zip___________ Phone ____________________ Fax _____________________ Company __________________________________________ Contact ___________________________________________ Address ___________________________________________ City _________________ State ________ Zip___________ Phone ____________________ Fax _____________________ Company __________________________________________ Contact ___________________________________________...
Page 101
addresses & phone Company __________________________________________ Contact ___________________________________________ Address ___________________________________________ City _________________ State ________ Zip___________ Phone ____________________ Fax _____________________ Company __________________________________________ Contact ___________________________________________ Address ___________________________________________ City _________________ State ________ Zip___________ Phone ____________________ Fax _____________________ Company __________________________________________ Contact ___________________________________________ Address ___________________________________________ City _________________ State ________ Zip___________ Phone ____________________ Fax _____________________ Company __________________________________________ Contact ___________________________________________...
Page 102
addresses & phone Company __________________________________________ Contact ___________________________________________ Address ___________________________________________ City _________________ State ________ Zip___________ Phone ____________________ Fax _____________________ Company __________________________________________ Contact ___________________________________________ Address ___________________________________________ City _________________ State ________ Zip___________ Phone ____________________ Fax _____________________ Company __________________________________________ Contact ___________________________________________ Address ___________________________________________ City _________________ State ________ Zip___________ Phone ____________________ Fax _____________________ Company __________________________________________ Contact ___________________________________________...
Page 103
In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to www.xyleminc.com...
Need help?
Do you have a question about the Goulds CentriPro Series and is the answer not in the manual?
Questions and answers
Centripro S10020 control box, Circuit board "run" light is on showing float switch works, but pump does not run, (runs OK with the manual switch) - need troubleshooting assistance