Write/Read
ControlLines Property
Description
Sets the control lines of the specified test set. Control lines, provided through the front
panel connector of a test set, are used to control external equipment such as a part
handler. See your test set documentation to learn more about control lines.
VB Syntax
tset.ControlLines (chNum) = value
Variable
(Type)
tset
A
OR
An
chNum
(Integer) Channel number of the measurement.
value
(Double) Data value used to set control lines. Values are obtained by adding weights
from the following table that correspond to individual lines.
Refer to your test set documentation for setting control line values.
Return Type
Variant
Default
0
- Description
TestsetControl
object.
E5091Testset
object.
Line
Weight
1
1
2
2
3
4
4
8
5
16
6
32
7
64
8
128
The E5091A interprets SENS:MULT1:OUTP 0 as all lines LOW.