ANTARES 1U ICE - user manual WARRANTY For Warranty terms and conditions users should contact their local Eurotech Sales Office. TRADEMARKS All trademarks both marked and not marked appearing in this document are the property of their respective owners. REVISION HISTORY Issue no.
Eurotech reserves the right to revise this document and to change its contents at any time without obligation to notify any person of such revision or changes.
To avoid damage caused by ESD (Electro Static Discharge), always use appropriate antistatic precautions when handing any electronic equipment. Life support policy Eurotech products are not authorized for use as critical components in life support devices or systems without the express written approval of Eurotech. CE notice...
When transporting any module or system, for any reason, it should be packed using anti-static material and placed in a sturdy box with enough packing material to adequately cushion it. Any product returned to Eurotech that is damaged due to inappropriate packaging will not be covered by the warranty!
Introduction Introduction The ANTARES 1U ICE system serves as a high performance, compact 19" rack mount ruggedized PC system for applications in IT systems, machine control, and kiosk solutions. The ANTARES 1U ICE is powered by a high performance single board computer designed and manufactured by Eurotech. The motherboard and system components are designed for long life support with standard CPU options from the Intel Core i7 620UE 1.06GHz for quiet PCs, the Celeron P4505 1.86GHz and up to powerful...
• Front panel 256 x 64 pixel LCD display. • Auto-ranging 90-265V, 47-63Hz AC, Flex-ATX PSU. • DC power input option also available on request. Contact Eurotech’s sales team for details (see page Eurotech Worldwide Presence, page 23). • Two PCI Express expansion slots via an internal flexible riser.
Introduction ANTARES ICE ‘at a glance’ Front panel view Reset switch 256 x 64 LCD DVD/RW drive 2.5" HDD access cover On/off DVD eject switch Rear panel views Two Ethernet ports and four USB 2.0 ports Power supply Two SMA ports Lid retaining screw Two serial ports Optional VGA/Audio panel M4 Earth stud...
ANTARES 1U ICE - user manual Features of the ANTARES ICE The 1U high 19" Rack Mount enclosure offers a wide range of features. These are summarised below. Front panel • HDD activity indicator. • Reset switch access hole. •...
Connectors Connectors The ANTARES provides a range of connectors to connect external devices: Audio The connectors available from the back panel are: Connector Function See … HDMI 1 and 2 Page 12. J7A, J8A LAN 1, LAN 2 Page 13. J7B, J8B USB 1 and 2, USB 3 and 4 Page 13.
Page 12
ANTARES 1U ICE - user manual J4 ( HDMI ports 1 and 2) HDMI socket Signal name TMDS_DATA2_P TMDS_DATA2_N TMDS_DATA1_P TMDS_DATA1_N TMDS_DATA0_P TMDS_DATA0_N TMDS_CLK_P TMDS_CLK_N No Connect SCL (DDC CLOCK) SDA (DDC DATA) SHELL ETH_ANTARES_1U_ICE_USM...
Page 13
Connectors J7A and J8A (LAN 1 and 2) RJ-45 10/100/1000Mb/s. Signal name (10/100/1000) MD0+ MD0- MD1+ MD2+ MD2- MD1- MD3+ MD3- For a Gigabit Ethernet (10/100/1000) connection the network cable should be a CAT5 or above and include all four pairs. J7B (USB ports 1 and 2) and J8B (USB ports 3 and 4) USB type A connector.
Page 14
ANTARES 1U ICE - user manual J29 – COM1 and COM2 RS232 serial ports DB9 male. Signal name Signal name Data Carrier Receive Data Detect (DCD) (RX) Transmit Data Data Terminal (TX) Ready (DTR) Ground Data Set ready (DSR) Request To...
Page 15
Connectors Audio (LINE IN, MIC and Headphones) The audio connector pin is made up of the following parts: Ring Sleeve The pin settings for each connector are as follows: LINE IN - 3.5mm audio jack MIC - 3.5mm audio jack Headphones - 3.5mm audio jack PC99 colour: light blue.
ANTARES 1U ICE - user manual Internal configuration The following diagram shows the construction of the ANTARES ICE: PCI Express card carrier Mini PCI Express access panel ANTARES SBC AC power supply 3.5" SATA HDD slot " DVD/RW SATA drive 2 x 2.5...
Internal configuration Removing and fitting the PCI Express card module The PCI Express module contains the following components: PCI Express riser Tamper detect Slots in (Flex to ALTARES micro switch Retaining screw bracket for not shown) and cable position adjustment PCI Express card PCI Express card Locating slots for...
Page 18
ANTARES 1U ICE - user manual To fit a PCI Express card, follow these steps: Remove the blanking plate. Plug the card into the riser. Adjust and fix the support bracket to suit. Tighten the retaining screw. To re-fit the PCI Express Module, reverse the above procedure.
Internal configuration Tamper detect switch The tamper detect feature is triggered by the opening and closing of the lid. It is affected by a switch mounted on the PCI Express module: Tamper detect switch A tamper detection input is included within the real time clock circuitry of the ANTARES that operates in all power modes.
ANTARES 1U ICE - user manual Dimensions The unit complies with standard (IEC 60297 and IEC 60917) 19" Rack Mounting dimensions and fits into a standard rack cabinet. The rear of the unit must be supported when rack mounted. Weight The weight of the unit depends on the configuration used and the optional items chosen when ordering.
EMC conformity EMC conformity The European Directive 89/336/EEC, on Electro-magnetic Compatibility (EMC), requires that, generated electro-magnetic disturbance must, be in accordance with European Harmonized Standards, for Electro-Magnetic Emissions and Immunity. Generic emissions and immunity standards Emissions: EN55022: • Conducted Emissions EN55022, A1, A2 Class B •...