  • Page 1 INSTRUCTIONS FOR USE...
  • Page 2 pearly – 2...
  • Page 3 A GOOD CHOICE! We are glad to see you decided to rely on natural cycle control in the future. Please read these instructions carefully and completely for your own safety. For more infor- mation about how to use the device, please refer to the table of contents or to the alphabetical index.
  • Page 4: Table Of Contents

    CONTENT 1. First things first 7. Measurement period 2. Basics Clear the measurement period 3. User levels Change the measurement period 4. Function keys 8. Measuring your temperature Circle key, plus key, minus key General information Back to home Tips Fast forward Measuring your temperature Measurement errors...
  • Page 5 Fertility review Disposal 12. Further information 14. Maintenance and safety Printing out your data Cleaning Analysing your cycle data Maintenance Bluetooth Life span Setting the time and date Safety Fever Device identification Deleting stored data Skipping a measurement 15. Purpose and description Mini-USB cable 16.
  • Page 6: First Things First

    1. FIRST THINGS FIRST – Before using pearly you should discontinue taking the pill: to be fully effective, the software ® must exactly determine the time of ovulation. The pill, however, hinders ovulation. – Remove your hormone spiral before you begin. This is also recommended in case you use a copper spiral.
  • Page 7: Basics

    2. BASICS Press to open Battery indicator Fertility indicator Alarm symbol Measurement value Sensor Measurement symbol 07:30 29.06.06 Time of day/wake up time + date Menstruation indicator Intercourse indicator Function keys USB socket Battery compartment pearly 7 –...
  • Page 8: User Levels

    3. USER LEVELS Device is off Time level Press briefly = switch on Alarm Wake-up time Time of day Serial number/trial measurement 5 Sec. 07:30 13:46 0100 off/on Set wake-up time Set time Software and serial number 5 sec. 5 sec. hrs.
  • Page 9 press simultaneously = back to time level Fertility level Review Measurement value – Fertility indicator / cycle day Prognosis 36.63 36.65 5 sec. Displays last Displays next 99 days 6 days «M» no «M» yes press briefly «IC» no «IC» yes press briefly Bluetooth initialised...
  • Page 10: Function Keys

    4. FUNCTION KEYS Circle key Plus key – Use the circle key to switch between the – Use the plus key to move to the next field and menu levels time, fertility, and Bluetooth. make an input (e.g. confirm your period). –...
  • Page 11: Before You Begin

    5. BEFORE YOU BEGIN 1. Insert the battery 5. Input menstruation data post-hoc 2. Set the time/date (optional) 3. Setting the alarm time 6. Measurement the next morning 4. Activate the alarm 7. Read your fertility status 8. Input «M» for menstruation 1.
  • Page 12: Input Menstruation Data Post-Hoc (Optional)

    5. Input menstruation data 6. Measuring your temperature 7. Reading your fertility status The device displays your measurement value «M» post-hoc the next morning and your fertility for the day: If you have recorded «M» (menstruation data), Measure your basal body temperature daily red fertile input them into the device before taking the after waking up.
  • Page 13: Self-Test, Serial Number And Trial Measurement

    6. SELF-TEST, SERIAL NUMBER AND TRIAL MEASUREMENT When you begin, pearly will give you default values. These will be ® automatically deleted as soon as you have taken your own first mea- surement or input your previous menstruation data. The default values will come up again if you delete your own user data.
  • Page 14: Measurement Period

    7. MEASUREMENT PERIOD Measurement period As a rule, the wake-up time and measure- ment time will be identical and we recom- pearly monitors the measurement period. Based on the factual ® mend to let pearly wake you. ® time you measured your temperature, it determines the measu- - 3 +3 rement period for the upcoming days.
  • Page 15: Measuring Your Temperature

    8. MEASURING YOUR TEMPERATURE Measurement – general information Our system ultimately relies on the daily consistent measurement of your basal body temperature. The basal body temperature is the temperature you have immediately after waking up, before getting out of bed, thus before being active in any way. The more regularly you measure your temperature especially in the early phase, the faster the device will get to know your personal cycle.
  • Page 16: Measurement Errors

    MEASURING YOUR TEMPERATURE Once you are finished, you will hear a tone and Measurement symbol not on the measurement value will appear. If the measurement symbol is not on in the The fertility status for the day will also be morning, activate the alarm.
  • Page 17: Inputting Menstruation Data After Starting The Application

    9. INPUTTING MENSTRUATION DATA Just enter «M» on all days that your period Inputting «M»after using the lasts, at least on three consecutive days. application for some time As soon as pearly ® knows your cycle, the Inputting menstruation data after device will prompt you for «M»...
  • Page 18: Activating «M

    INPUTTING MENSTRUATION DATA Activating «M» Inputting «M» post-hoc Starting from the clock display: If you have «M» on a date unprompted by 1. It is possible to input previously recorded – Press the circle key once. pearly ® , you should activate «M». «M»...
  • Page 19: Inputting Intercourse

    10. INPUTTING INTERCOURSE Starting from the time view: Input only for the previous day: – Press the circle key once. You may only input intercourse for the cur- – To input for yesterday, press the minus rent day or the day before; it has no bearing key once.
  • Page 20: Fertility Indicator

    11. FERTILITY INDICATOR Fertility indicator Starting from the time view, press the circle The device gets to know your cycle key once. Fertility will be displayed in three colours: The more regularly you measure the faster the – You will see the measurement value of the Green infertile device will get to know your personal cycle.
  • Page 21: Fertility Preview

    Fertility preview Fertility review Starting from the actual measurement value Starting from the current measurement value: You may review your fertility status for the – Press the minus key once. By pressing this key – Press the plus key once to see your fertility last 99 days.
  • Page 22: Bluetooth

    12. ALSO GOOD TO KNOW Printing your data Bluetooth Setting the time and date The stored data may be read out if you – Plus key, initialising interface. Press the circle key to select the time view wish using: with «Time and date». –...
  • Page 23: Fever

    Fever Skipping a measurement Mono-phases If the measurement value indicates a fever If you skip one or several measurements, the If you don’t ovulate in a certain cycle, pearly ® (higher than 37.80°C), «F» for fever will be device will determine your fertility based on will show this throughout in red.
  • Page 24: Pregnancy Indicator

    ALSO GOOD TO KNOW Pregnancy indicator Restarting the application after an Restarting the application after a Normally pearly ® will indicate a probable interruption pregnancy pregnancy starting from the 18th day after The date, year and time will continue to run In the first six weeks after a pregnancy there fertilization, by showing the arrows pointing to automatically until the battery is empty.
  • Page 25: Loss Of Data

    13. TECHNICAL SPECS AND DISPOSAL Device Battery – Dimensions: length 9.7 cm, width 6.3 cm, 1 micro AAA 1.5 V battery of good quality (leaka- height 2.4 cm ge protected) or 1.2V nickel metal hydride cell – Weight: 70 grams with a low rated self-discharge.
  • Page 26: Maintenance And Safety Cleaning

    14. MAINTENANCE AND SAFETY Cleaning Maintenance Life span – Measuring sensor: Please only use lukewarm Your computer has been designed and pro- – The devices have a shelf-life of max. 7 years. water to clean the sensor; keep away from duced with great care and should thus also be water;...
  • Page 27: Purpose And Description

    15. PURPOSE AND DESCRIPTION Product labelling The pearly cycle computer is a battery-powered minicomputer used ® to measure a woman’s daily wake-up temperature (basal body tempe- rature) in order to determine and visualize her fertile days. The fertile Name of manufacturer period is calculated based on the body temperature that is measured Date manufactured orally right after waking up with the cycle computer sensor, then...
  • Page 28 16. TROUBLE-SHOOTING – SERVICE AND HELP Readings impossible, or unwanted – Check whether the temperature reading time limithas been cleared interruption in reading (thermometer symbol not blinking) – Carry out a trial measurement (see p. 13 trial measurement) – Check sensor for damage Alarm did not go off –...
  • Page 29: Index

    INDEX Inputting intercourse Cancel / repeat measurement Basics Print data Basic rules for all inputs Automatic switch-off Not making measurements Basal body temperature Deleting stored date User levels Inputting menstruation date «M» Battery – setting date Activating «M» Battery status Bluetooth Inputting «M»...
  • Page 30 Measurement symbol not on Faults Measurement period Technical specs Changing measurement period Temperature rise/fever 23/24 Measurement period cleared Tips for measuring your temperature Mono-phases Setting the time pearly gets to know your cycle ® USB cable Maintenance Maintenance After the pill Alarm - activating Trial measurement Alarm - setting...