Download Print this page

STEMCELL SepMate 50 Directions For Use

Polypropylene tube with insert. gamma-irradiated

Advertisement

Quick Links

INTENDED USE

SepMate™ tubes are designed for the in vitro isolation of
mononuclear cells (MNCs) from human whole peripheral blood and
cord blood samples by density gradient centrifugation.

PRODUCT DESCRIPTION

Polypropylene tube with insert.
STORAGE
Store at room temperature (15 - 25°C).
DIRECTIONS FOR USE
Ensure that sample, phosphate-buffered saline with 2% fetal bovine
serum (PBS + 2% FBS; Catalog #07905), density gradient medium
(see Notes on reverse page), and centrifuge are all at room
temperature (15 - 25°C).
1.
Add density gradient medium to the SepMate™ tube by
carefully pipetting it through the central hole of the SepMate™
insert. Refer to Table 1 for required volumes. The top of the
density gradient medium will be above the insert.
Note: Small bubbles may be present in the density gradient
medium after pipetting. This will not affect performance.
2.
Dilute sample with an equal volume of PBS + 2% FBS.
Mix gently.
For example, dilute 5 mL of sample with 5 mL of PBS +
2% FBS.
3.
Keeping the SepMate™ tube vertical, add the diluted sample
by pipetting it down the side of the tube. The sample will mix
with the density gradient medium above the insert.
Note: The sample can be poured down the side of the tube.
Take care not to pour the diluted sample directly through the
central hole.
4.
Centrifuge at 1200 x g (see Notes) for 10 minutes at room
temperature, with the brake on.
Note: For samples older than 24 hours, a centrifugation time of
20 minutes is recommended.
5.
Pour off the top layer, which contains the enriched MNCs, into
a new tube. Do not hold the SepMate™ tube in the inverted
position for longer than 2 seconds.
Note: Some red blood cells (RBCs) may be present on the
surface of the SepMate™ insert after centrifugation. This will
not affect performance.
6.
Wash enriched MNCs with PBS + 2% FBS. Repeat wash.
Note: Centrifuging at 300 x g for 8 minutes at room
temperature, with the brake on, is recommended.
TOLL FREE PHONE
1 800 667 0322
INFO@STEMCELL.COM
TECHSUPPORT@STEMCELL.COM
SepMate™-50
CATALOG #15450
20 TUBES/BAG
CATALOG #15460 5X20 TUBES/BAG
SepMate™-15
CATALOG #15415
20 TUBES/BAG
CATALOG #15420 5X20 TUBES/BAG
Gamma-irradiated.
FOR RESEARCH USE ONLY. NOT INTENDED FOR HUMAN OR ANIMAL DIAGNOSTIC OR THERAPEUTIC USES.
PHONE
+1 604 877 0713
FOR GLOBAL CONTACT DETAILS VISIT WWW.STEMCELL.COM
SEPMATE™ PROCEDURE
Numbers in brackets refer to steps under Directions for Use.
Centrifuge at
1200 x g for 10 min
(4)
Plasma
MNCs
Density gradient
medium
RBCs
Table 1: Density Gradient Medium Volumes
SEPMATE™
INITIAL BLOOD
TUBE
SAMPLE (mL)
15
0.5 - 4.0
15
> 4 - 5
50
4 - 17
Add density
gradient medium
(1)
Pipette diluted sample
down the side of the tube
(3)
Pour
Wash enriched
(5)
MNCs with
PBS + 2% FBS.
Repeat wash
(6)
MNCs
DENSITY GRADIENT
MEDIUM (mL)
4.5
3.5
15
VERSION 2.0.0
DOCUMENT #29251

Advertisement

loading
Need help?

Need help?

Do you have a question about the SepMate 50 and is the answer not in the manual?

Questions and answers

Summary of Contents for STEMCELL SepMate 50

  • Page 1: Intended Use

    FOR RESEARCH USE ONLY. NOT INTENDED FOR HUMAN OR ANIMAL DIAGNOSTIC OR THERAPEUTIC USES. TOLL FREE PHONE 1 800 667 0322  PHONE +1 604 877 0713 VERSION 2.0.0 INFO@STEMCELL.COM  TECHSUPPORT@STEMCELL.COM  FOR GLOBAL CONTACT DETAILS VISIT WWW.STEMCELL.COM DOCUMENT #29251...
  • Page 2 Copyright © 2013 by STEMCELL Technologies Inc. All rights reserved including graphics and images. STEMCELL Technologies & Design, STEMCELL Shield Design, Scientists Helping Scientists, SepMate, and RosetteSep are trademarks of STEMCELL Technologies Inc. Lymphoprep is a trademark of AXIS-SHIELD. Ficoll-Paque PLUS is a trademark of GE Healthcare Limited. All other trademarks are the property of their respective holders.

This manual is also suitable for:

Sepmate 15