Advertisement

L
L
O
'
O
'
W
N
E
R
S
W
N
E
R
S
T
P
T
P
H
E
H
E
W
W
I
N
E
O
F
I
N
E
O
F
M
M
O
O
M
M
A
N
U
A
L
A
N
U
A
L
V
V
R
O
F
E
S
S
I
O
R
O
F
E
S
S
I
O
S
S
A
T
E
R
O
F
A
T
E
R
O
5
1
0
5
1
0
D
E
L
D
E
L
I
I
A
N
D
N
S
T
A
N
D
N
S
T
3
.
3
3
.
3
E
R
S
I
O
N
E
R
S
I
O
N
N
A
L
N
A
L
T
E
N
E
R
S
F
T
E
N
E
R
S
0
0
A
L
L
A
T
I
O
N
A
L
L
A
T
I
O
N
G
G
U
I
D
E
U
I
D
E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROFESSIONAL Series and is the answer not in the manual?

Questions and answers

Reiss Thayer
February 26, 2025

What’s yours phone number? or how do I order the brine valve assembly branded

Summary of Contents for Puratech PROFESSIONAL Series

  • Page 1 ’ ’...
  • Page 2 All defective parts must be returned, along with the equipment consequential damages, so the above limitations and exclusion serial number and date of original installation, to PuraTech ® may not apply to you. This warranty gives you specific legal...
  • Page 3: Table Of Contents

    Installation Steps and Start-Up Procedures ....................10 Bypass Valve ............................... 14 Setting and Using the Controller ........................15 Service Settings ............................16 Optional Plumbing Procedures ........................19 Assembly and Parts ............................. 21 Troubleshooting ............................29 Water Conditioner Specifications ......................... 31 PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 4: Owner Information

    WNER NFORMATION General Information Congratulations on choosing a superior PuraTech water treatment appliance! Soon you and ® your family will be enjoying clean, clear water. Use this guide to attain the maximum benefit from the appliance. As an owner, you may find the first few pages to be the most helpful. If you have trouble with the operation of the appliance, see Troubleshooting in the back of this manual or contact your independent dealer.
  • Page 5: Getting Maximum Efficiency From The Appliance

    Note: Ensure that the bottom of the controller is firmly locked onto the four tabs on the top of the Buttons drive end cap assembly. See Cabinet and Cover Assemblies diagram later in this manual. Figure 1: Five-Button Controller PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 6 Regenerate The Regenerate button at the bottom of the controller is used when starting the water conditioning appliance, to start an immediate regeneration, or to restore capacity if you run out of salt. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 7: Customer Settings

    When the desired number of people is displayed, press Display to exit the Customer Setting mode. When you press the Display button at “# People,” the values are saved, and the controller returns to normal operating mode. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 8: Installation And Maintenance Information

    See Installation Steps and Start-Up Procedures.  Electricity—The transformer supplied is for a standard 115 volt, 60-cycle AC outlet for locations in North America or 220 volt, 50-cycle AC outlet for locations outside North America. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 9: Precautions

    Do not allow the appliance or drain line to freeze. Note: A bacteriostasis claim does not mean that these devices will make microbiologically unsafe water safe to consume or use. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 10: Installation Steps And Start-Up Procedures

    Ensure that the water heater has an adequately rated temperature and pressure safety relief valve. For outside installations, the appliance should be enclosed so it is protected from the weather. Figure 2: Appliance Placement PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 11 (See Figure 4). Do NOT overtighten the connections on the plastic threads. Check the arrows on the valve to ensure that the water flows in the proper direction. Caution: Do NOT plumb your appliance in backward. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 12 Place the bypass valve in the Bypass position. Turn on the main water supply. Open the nearest cold water faucet to flush the plumbing of any excess soldering flux, air, or any other foreign material until the water runs clear. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 13 After you add salt, including adding it after the tank has run out of salt, wait two hours for saturated brine before starting any regeneration. Caution: Use of potassium chloride when iron and/or manganese are present in the raw water supply is not recommended. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 14: Bypass Valve

    Service position. To blend hardness back into the water using the bypass, turn the knob slightly from the Service position toward the Bypass position. Figure 6: Bypass Valve PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 15: Setting And Using The Controller

    Always wait until the cycle position displays before advancing to the next cycle position. Press and release the Regenerate button in Normal operating mode to schedule a regeneration tonight or toggle it off. Figure 7: Regenerate Button PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 16: Service Settings

    When iron and/or manganese is present in the water supply, do not use potassium chloride as a Warning: regenerant. Iron and/or manganese bacteria may develop and foul the conditioning media and may void the warranty. This table continues on the next page. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 17 If this value is set to Yes, the appliance will be forced to regenerate every 72–96 hours unless a regeneration based on water usage occurs within the time interval. The value should always be set to Yes if iron is present in the water. PuraTech Owner’s Manual 12/11/2013...
  • Page 18 Service Settings, Cont. Mode 1 (Timer Mode) and Mode 2 (Demand Delayed Mode) Setting Chart This section provides guidance for using different Service Settings to achieve the desired capacity. PuraTech Model 5100 Mode 1 and Mode 2 Regeneration Frequency Mode 1 only 96 hour regeneration (if iron present—yes)
  • Page 19: Optional Plumbing Procedures

    Turn the fitting counterclockwise until you feel the threads engage and then tighten to prevent cross threading. Do NOT over tighten the fittings. Caution: Do NOT allow heat from the torch to transfer to the plastic valve component, which could be damaged. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 20 Allow adequate time for the joint to cure properly. Exact drying time is hard to predict because of environmental variables. Follow the recommended joint curing times on the primer and cement container labels. PuraTech Owner’s Manual 12/11/2013...
  • Page 21: Assembly And Parts

    Screw 95204 Valve Cover Assembly 95205 Salt Port Lid 93245 12 Volt Transformer/Power Cord 95203 Support Panel 95202 Cabinet C0700 2 Piece Overflow 93848 3/8-inch Brine Tubing, 2 feet (0.6 m) 54550 Computer Control Assembly PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 22 95505 Resin Tank Assembly 93808 O-Ring 95301T Drive End Cap Assembly 93809 Screw 90828 O-Ring 93504 Injector Assembly 93809 Screw 93524 Drain End Cap Assembly 93835 Spacer Tube V185 Drain Line Fitting 93842 Drain Line PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 23 Valve, the Nozzle hole should line up with the Throat. Flush screen with water to clean. The over-mold gasket seals between the Injector Nozzle and the Injector Cap. 53235 Injector Cap Holds the injector assembly together and seals the assembly to the Main Control Valve. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 24 Brine Valve Assembly (Barbed) 90821 O-Ring 54502 KIT Magnet Disk Assembly 90828 O-Ring 93808 O-Ring 53322 Drive Piston Assembly 93839 Drain Gasket 95301T Entire Assembly (all of the above parts except 1, 2, and 13) PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 25 Slide Piston Assembly Onto Piston Slide. Rotate The Piston Assembly 90 Degrees Position Piston Assembly (53322) Vertical Clockwise Until You Hear An Audible Click Push Toward End Cap to Stop. As It Snaps Into Place PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 26 Bypass Assembly Figure 13: Bypass Assembly Part # Description Quantity 54512 Bypass Assembly (also includes items 2–6) 93860 Turbine Sensor/Cap Assembly 90809 Sensor Cap Screw, self-tapping 54320 Plastic Turbine Axle 90522 Turbine Assembly 93838 O-Ring PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 27 The Cap is held in place by two 3/4-inch thread-cutting screws that engage the Housing flange. An End Cap O-Ring seals the Cap and Housing. Place the O-Ring onto the housing end cap, lubricate with silicone grease, and insert the Cap into the housing using a twisting action. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 28 Assembly and Parts, Cont. Safety Shutoff Assembly Figure 15: Safety Shutoff Assembly Part # Description Quantity 93811-20.0 Safety Shutoff/Brine Well Assembly PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 29: Troubleshooting

    With 12 VAC present at controller, replace the controller High ambient room temperature. If the No action necessary temperature exceeds 120°F (49°C), the display will blank out. This does not affect the operation of the controller PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 30 Intermittent pressure drop from feed source Install check valve on the inlet water line to the appliance (Check local plumbing codes first) Brine valve drips water back to brine tank Clean brine valve housing, replace piston assembly PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 31: Water Conditioner Specifications

    12 VAC, 50/60 Hz, 0.015kW-hr Plumbing connections 1" male (MNPT) Shipping weight—approximate–lb (kg) 105 (48) The state of Wisconsin limits iron reduction claims to 5 ppm. Use clean white pellet salt, cube-style salt, or solar salt. PuraTech Owner’s Manual 12/11/2013 ®...
  • Page 32 PuraTech ® has these third-party listings: Tested and certified by WQA according to CSA B483.1. Hague Quality Water, International 4343 S. Hamilton Rd. Groveport, OH 43125 Phone: 614-836-2115 LITHO USA ©2013 51900PT RV1213–Ver. 3.3...

This manual is also suitable for:

5100

Table of Contents

Save PDF