Incorrect installation, adjustment, change Remove Refrigerator ..................28 to, or maintenance of this refrigerator can Replace Refrigerator ..................28 cause personal injury, property damage, or both. Have service and maintenance work done by your dealer or by an authorized Norcold Service Center. www.norcold.com N10DCX...
® changes at any time without notice. If unable to resolve technical issues using the information provided in this manual, technical support is available through NORCOLD ® Certifi cation and Code Requirements Customer Service Center: ...
Serial Number Model Number Amount of refrigerant in cooling system DC Voltage / Amperage SPECIFICATIONS N10DCX - Electronic ON/OFF, Mode, Temperature Set Multiple LED indicator lights Five (5) Temperature Settings (Separate settings for freezer and fresh food compartments) Night Mode Rough Opening Dimensions ------------------59.88 - 60.01 high x 23.50 - 23.63 inched wide x 24.00 inches deep...
Exploded Views Fig. 2 - Front view Description Control Panel Control Panel Label Control Board Control Housing Control Housing Bracket (3x) Fan and Housing Light Housing Light Light Cover Door Light Switch www.norcold.com SERVICE MANUAL...
■ Shorten the life of the refrigerator cool- ing system. ■ Cause poor cooling performance of the refrigerator. ■ Cause continuous operation of the refrigerator cooling system. ■ Cause fast battery discharge. ■ Void the refrigerator warranty. www.norcold.com SERVICE MANUAL...
Do the tests in “Self - Test Diagnostics” section. Are any Refer to “Self - Test Diagnostic Chart.” error codes found? Refer to “Diagnostic Symptom Chart.” If necessary, remove the refrigerator from the enclosure. Refer to the “Refrigerator Enclosure” section. www.norcold.com N10DCX...
Fig. 4.2 - Female connectors Attach a female connector to each LED wire lead. Step 2. Disconnect 12 VDC 12/24 Vdc Fig. 4.3 - 12 VDC Disconnect the 12 VDC input wire from the positive terminal of the control module. www.norcold.com SERVICE MANUAL...
Refer to "Fault Code - The voltage is outside the cut out setting. "E3"" on page 26. The fresh food compartment door has Refer to "Fault Code - been open for more than two (2) minutes. "E4"" on page 26. www.norcold.com N10DCX...
Repair DC supply voltage. 10.4 - 15.4? Test the refrigerator. With freezer and fresh food compartments at temperature setting “5”, measure voltage at DC connector. Repair DC supply voltage. Test the refrigerator. 10.4 - 15.4? Continued on next page. www.norcold.com SERVICE MANUAL...
Page 12
Troubleshooting Compressor Control Module, cont’d. Continued from previous page. With freezer and fresh food compartments at temperature setting “5”, measure voltage at terminal “+”. Repair refrigerator power cord. 10.4 - 15.4? Test the refrigerator. Replace control module. Test refrigerator. www.norcold.com N10DCX...
“5”, make sure that the exterior cooling fan is operating. Is the fan Replace the refrigerator. operating? Measure DC voltage at control module terminal “+”. Fan has failed. Replace the fan. 10.4 - 15.4? Replace control module. www.norcold.com SERVICE MANUAL...
Remove refrigerator from enclosure, but keep DC power supply connected. Turn refrigerator OFF for a minimum of five (5) minutes to allow internal system pressures to equalize. Turn refrigerator back ON. Does code Replace the refrigerator. 3 return? Repair complete. www.norcold.com N10DCX...
- The ambient operating temperature is lower than 110°F (43° C). Correct input voltage. 10.4 - 15.4? unit Reduce load on unit. overloaded? Is fan operating, Replace the refrigerator. coils clean/not blocked? Replace control module. www.norcold.com SERVICE MANUAL...
- Upper and lower vents are not blocked. - Condenser coil is clean. - Fan is operating. - Ambient operating temperature is lower than 110°F (43° C). Test the unit. Does code Replace control module. 5 return? Repair complete. www.norcold.com N10DCX...
Examine DC fuse. Replace if necessary. DC power? With the refrigerator turned “OFF”, use a DVOM to check input voltage. The input voltage must be higher than 11.7 VDC. Is input voltage Correct input voltage. Test unit. correct? Continued on next page. www.norcold.com SERVICE MANUAL...
Page 18
Replace compressor wire harness. wire harness Test unit. With compressor harness unplugged from the compressor, measure resistance between all three (3) current lead-in pins on the compressor. measured values about Replace the control module. the same? Replace the refrigerator. www.norcold.com N10DCX...
Disconnect wires at control module terminals”C” and “T”. Repair shorted wires between optical display module and control module. Did unit stop operating? Test unit. Is the magnet valve bad? Replace the refrigerator. Replace the control module. Test unit. www.norcold.com SERVICE MANUAL...
Check temperature setting of freezer and fresh food compartments. Inspect door seal, hinges, and latch for correct operation. operating Repair as needed. Test refrigerator. correctly? www.norcold.com N10DCX...
DC power supply connected. Inspect condenser coil for restriction. Is it Remove restriction. Clean as needed. restricted? Check for 12 VDC at terminal (+) on the control module. Is voltage Fan has failed. Replace refrigerator. correct? Replace control module. www.norcold.com SERVICE MANUAL...
Is wiring at Refer to the Installation Manual for least #12 the recommended wire size. gauge? Check DC voltage at control module. Is voltage Correct high resistance (voltage drop) in below 10.4 supply circuit. VDC? Recharge or replace battery. www.norcold.com N10DCX...
Correct input voltage. 10.4 - 15.4 VDC? unit Reduce load on unit. overloaded? Disconnect thermistor wire from terminal “C” on the cooling unit Repair complete. control module. Test the refrigerator. Does the refrigerator still cut out? Contact Customer Service. www.norcold.com SERVICE MANUAL...
Remove thermistor cover in fresh food compartment and check connection of thermistor wire to thermistor. thermistor wire Correct connection. connected? Check connection of thermistor wire to the refrigerator electronic controls. Refer to the wiring diagram. thermistor wire Correct connection. connected? Replace Thermistor. www.norcold.com N10DCX...
Remove thermistor cover in freezer compartment and check connection of thermistor wire to thermistor. thermistor wire Correct connection. connected? Check connection of thermistor wire to the refrigerator electronic controls. Refer to the wiring diagram. thermistor wire Correct connection. connected? Replace Thermistor. www.norcold.com SERVICE MANUAL...
Fault Code - "E4" Make sure: ■ the light switch closes when the door closes. ■ all of the connections to the refrigerator electronic controls are intact. Possible Cause: The door has be open for more than two (2) minutes. www.norcold.com N10DCX...
2. Remove the mounting screws from each mounting bracket. Pull the refrigerator forward. Replace Refrigerator 1. Push refrigerator fully into enclosure. Install screw into each mounting bracket. 2. Connect all power supplies to the refrigerator. www.norcold.com N10DCX...
Need help?
Do you have a question about the N10DCX and is the answer not in the manual?
Questions and answers
What does the magnetic K switch do