McKesson Lumeon Series User Manual

Dopplers
Hide thumbs Also See for Lumeon Series:

Advertisement

OPPLERS
USER'S MANUAL
© 2015 McKesson Medical-Surgical Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lumeon Series and is the answer not in the manual?

Questions and answers

Summary of Contents for McKesson Lumeon Series

  • Page 1 OPPLERS USER’S MANUAL © 2015 McKesson Medical-Surgical Inc.
  • Page 2: Table Of Contents

    Thank you for choosing McKesson LUMEON SERIES Doppler Systems. Your total ® satisfaction is our highest priority as we strive to continually improve our products and services. Please contact us with any suggestions. We look forward to enjoying a long-term...
  • Page 3: Intended Use/Contraindications/Warnings

    The main handheld unit is ergonomically designed to fit the palm of your hand with comfort and allow easy access to each control feature. Each unit is individually tested and inspected to ensure the highest quality standards. SSQ – Superior Sound Quality. Every McKesson LUMEON ® SERIES Doppler is designed with a state of the art sound system that produces excellent sound quality and long-term reliability.
  • Page 4 1158 1159 1160 Probes McKesson LUMEON ® SERIES Doppler ultrasound transducers were designed to meet your specific applications needs. Each probe has been ergonomically designed for comfort while providing excellent maneuverability for locating the fetus or vascular target. Each probe is carefully measured and tested to ensure it meets exacting performance standards.
  • Page 5: Operation And Installation

    OPERATION AND INSTALLATION (Some features are optional) SPEAKER GRILL ON/OFF BATTERY LEVEL INDICATOR LED ON/OFF PROBE BUTTON CLIP RECHARGE PROBE CONNECTOR HEAD/PHONE/AUDIO CONNECTOR “PLAY” LED “RECORD” LED BELT CLIP MODEL/SERIAL NUMBER LABEL VOLUME SLIDER BATTERY DOOR...
  • Page 6: Obtaining Doppler Signals

    This complete power shutdown preserves the life of the batteries and ensures the unit will be ready for operation in case it was accidentally left on. Diagnostic Monitoring (LCD Display units only) Once the unit is on, the McKesson LUMEON ® SERIES Doppler display units perform a series of diagnostic checks.
  • Page 7 The heart rate calculation will display either the maternal rate or the fetal rate, whichever portion of the signal is stronger. If the fetal heart sounds cannot be located using the McKesson LUMEON ®...
  • Page 8: Maintenance And Cleaning

    EPA. Clorox ® Broad Spectrum Quaternary Disinfectant is the only disinfectant that is Wallach Surgical Devices approved for use on this McKesson LUMEON ® SERIES product. Follow the manufacturer’s instructions and wipe until it is dry of solutions. Examiners should wash hands and change gloves after every exam.
  • Page 9: Replacing Batteries

    REPLACING BATTERIES WARNING: Replace rechargeable batteries only with batteries supplied by McKesson Medical-Surgical Inc. See accessories list for part number and re-order information. WARNING: The battery compartment only accepts AA size batteries. See accessories list for part number and re-order information.
  • Page 10: Clinical References

    3 V/meter. Interference during normal operation may occur in the presenceof fields stronger than 3 V/meter. If this occurs, try to increase the distance between the McKesson LUMEON ® Doppler and the source of interference. Contact a McKesson LUMEON ® representative for more information.
  • Page 11: Specifications

    SPECIFICATIONS Degree of protection against electric shock: Type B Applied Part Class II Equipment Degree of protection against ingress of water: All probes: IPX4 – extending 2.5 cm from tip IPX1 – entire probe 2.5 cm from tip, excluding connector Designed and tested to meet: IEC601-1, IEC60601-1-2, IEC60601-1-4, IEC60601-2-37, EN5011-A Dimensions (h x w x l):...
  • Page 12 ® Transducer Model: McKesson LUMEON SERIES 4 MHz Operating Mode: Continuous-Wave (cw) Application(s): Peripheral Vascular SPTA.3 SPPA.3 ACOUSTIC OUTPUT (mW/cm (W/cm Global Maximum Value 0.05 .278 (Mpa) 0.07 (mW) 47.2 0.047 (MHz) Associated (cm) Acoustic Parameter (cm) Beam Dimensions (cm) Az (cm) 0.45...
  • Page 13 Obstetrical Probe Information: MODEL NUMBER VARIABLE DESCRIPTION 2 MHz 3 MHz (max) (mW/cm 19.6 15.5 SATA (mW) 48.0 24.4 Effective Radiating Area (cm 2.45 1.57 Ultrasound Frequency (MHz) 2.1 MHz 3.2 MHz Pulse Duration Repetition Freq. the spatial-average temporal-average intensity (mwatts per cm SATA the derated spatial-peak temporal-average intensity (mwatts per cm SPTA.3...
  • Page 14 NOTES:...
  • Page 15 NOTES:...
  • Page 16 ® Lumeon is a registered trademark of McKesson Medical-Surgical Inc. Questions? Call 1-800-777-4908 Distributed By McKesson Medical-Surgical Inc. Richmond, VA 23233 Made in USA MAN0025-IFU • Rev. A • 10/15...

Table of Contents

Save PDF