Model: 400 v, 230 v
with navigator 2.0.
air heat pump with
inverter-technology (48 pages)
Summary of Contents for iDM AERO ILM 2-7
Page 1
A d d i t i o n a l M o d e l : H G L wi t h N AV I GATO R 2.0 C o n t ro l Modulation air-water-heat pumps for Indoor Installation HEAT PUMPS FROM AUSTRIA www.idm-energie.at...
1.15. Application range 1.16. Scope of delivery 1.17. Accessories 2. T ECHNICAL DATA 2.1. Dimensions of AERO ILM 2-7 and AERO ILM 4-13 2.2. Technical data 3. D IMENSIONING 3.1. Heating performance diagrams AERO ILM 2-7, according EN14511 3.2. Heating performance diagrams AERO ILM 4-13, according EN14511 3.3.
Page 3
8.2. Errors 9. A PPENDIX 9.1. AERO ILM 2-7 - Performance data heating - detailed 9.2. AERO ILM 2-7 - Performance data cooling - detailed 9.3. AERO ILM 4-13 - Performance data heating - detailed 9.4. AERO ILM 4-13 - Performance data cooling - detailed 9.5.
To prevent water damage, the conden- hoisting equipment. sate bin and the condensate hose have to be checked regularly for contamination. (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
- the regulations of the professional associations - the pertinent laws, standards, regulations and pro- safeguarded against theft by appropriate on-site visions, e.g. DIN, EN, DVGW, VDI and VDE. measures. - Provisions of the local public utilities. (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
A copper-welded stainless steel plate heat exchanger sule compressor (AERO ILM 4-13) or rolling piston is used as condenser. The machine frame consists of compressor (AERO ILM 2-7) perfectly. The housing is thus completely without a thermal bridge and thus features optimum sound in- as condenser sulation values.
2. Technical data Technical data 2.1. Dimensions of AERO ILM 2-7 and AERO ILM 4-13 outlet front inlet from above (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
Outside air outlet - maximum dB(A) Night mode dB(A) Indoor - nominal dB(A) Indoor - maximum dB(A) The sound pressure level can be calculated with the iDM-sound calculation tool Dimensions HxWxD 1850/910/830 1850/910/830 Tilt hight 2028 2028 Weight Sound data with weather shield-grilles, without air hose and without air duct. If the fan speed will be raised, the sound power level raises too.
Page 9
Technical data Heatpump type unit AERO ILM 2-7 AERO ILM 4-13 Maximum heatpump flow temperature m³/h 1.42 m³/h 0.42 0.77 Integrated loading pump Yonos Para 7.0 Stratos Para 25/1-9 Free residual pressure loading pump at nominal flow rate Pressure loss heating side Flow- and return connections heating side 1“...
The standard outside temperature is additionally re- quired. This is determined by the geographical loca- tion and can be found on the IDM homepage and ob- tained from various institutions. Heating energy required: Heating performance diagram AERO ILM 4-13...
The heating of liquids other than heating water is not permitted (see heating water quality). Heat pumps are naturally subject to pressure or temperature-dependent operating limits (see diagram below). Operation outside these limits is not permitted. AERO ILM 2-7 - heating [°C] R410A [°C]...
Page 17
AERO ILM 4-13 - cooling [°C] R410A 10 15 20 25 30 35 40 45 50 [°C] outdoor temperature If the outside temperatures falls below or exceeds the application range , the heat pump turns (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
(only for HGL-usage in cooling mode) not used not used Heat pump return Heat pump return Main current Main current Sensor and control lines Sensor and control lines height-adjustable feet (50 mm) height-adjustable feet (50 mm) (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
In coastal installation, a minimum dis- tance of 5 km from the coast must be observed. If this safety distance is not observed, there could occur increased corrosion. These cases are excluded from the guarantee. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 22
(directivity correction Dc) of the relevant place of immission according the following formula: 3: Spherical spreading into 1/8 space: WAeq situations of heat pumps and the corresponding di- rectivity correction. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 23
6 dB location should be avoided sensitivity The rating level Lr shall be obtained by summing the calculated immission level and the applied correc- pressure levels accordingly. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
The installation of heat pumps should be omitted around the heat pump (as shown in the illustration). 1. Betondecke 2. Trittschalldämmung 3. Estrich 4. Ausnehmung 5. Schalldämmmatte (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
- Heat pumps must not be installed in rooms with condensate. For this purpose a drain- age must be provided. - Air intakes and outlets have to be safeguarded against theft by appropriate on-site measures. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
To facilitate accessibility the outlet opening on the right-hand side should be given preference! When using a light shaft this must be at least as wide as the wall opening. The depth must be at least 400 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 27
(incl. outlet panel) 192502 ... Protective grating outlet air or 192532 ... Mesh grille outlet (12 mm) 192502/192532 193801 Only move the heat pump with mounted Avoid intensive pressure against the panels! wall! (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 28
The horizontal elements are principally laminated on the front side. This guarantees an optimum leak tightness! the cellular rubber on the inner side! The metal frame is thus surrounded completely with insulat- ing material and cold bridge free! (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 29
If there is any gap at the outlet or inlet opening due to ing the 4 screws which are included in the delivery contents. adjustable machine feet. The screws on the panel have to be carefully tightened manually. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
When using a light shaft this must be at least as wide as the wall opening. The depth must be at least 400 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 31
A is the length of the 1,000 mm 1,150 mm air duct plus 150 mm. 1,500 mm 1,650 mm wall insulation! The minimum width of the wall insulation must be 50 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 32
Finally, the foamed area of the wall breakthrough must be covered with the panel (duct wall connection) lies in front of the wall. At the which ensures the stability of the wall socket. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
The air ducts can be connected to the left or to the right of the heat pump. Heating and electrical connections can also be made on both sides. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 34
The air duct can be cut to length as required, the length B is the length of the air duct plus 166 wall insulation! The minimum width of the wall insulation must be 50 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 35
Thus, the blown air sinks and moves down to the lowest point. This is especially important when installing with rising or falling terrain. The air ducts are supplied including mounting material (screws, washers, nuts)! (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
The air connections can be connected to the left or right side of the heat pump. In consequence this means that heating connections and electrical connections can be either on the left-hand side or on the right-hand side. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 37
5 m, the outlet panel, a wall mounting panel and 2 pieces hose clamps for assembly of the hose to the outlet panel and to the wall mounting panel. (min. bend radius is 600 mm) (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 38
The minimum width of the wall insulation must be 50 mm. When using a light shaft this must be at least as wide as the wall opening. The depth must be at least 400 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 39
This has opening using suitable assembly material. Four bore purpose! Flexible hose: The hose can be cut to length as desired! In connect- is telescoped at the two ends. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
(2 m, 3 m und 5 m) and can be cut to length as needed! When using a light shaft this must be at least as wide as the wall opening. The depth must be at least 400 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 41
5 m, the outlet panel, a wall mounting panel and 2 pieces hose clamps for assembly of the hose to the outlet panel and to the wall mounting panel and the cover panel sideways for free cutting. (min. bend radius is 600 mm) (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 42
Increase the Wall opening according the insulation. Outlet opening to the right NOTE: Clear dimensions. Increase the Wall opening according the insulation. wall insulation! The minimum width of the wall insulation must be 50 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Page 43
When replacing the panel, ensure that the insulation of the cover is cleanly closed at all times. If this is not the case, condensation can occur on the heat pump cover and also on the remaining panel. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
The protective sleeves for the hydraulics and cables are provided by the manufacturer on both sides. to be installed as shown in the diagram below. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
After the heat pump is placed in the place of instal- lation, the wiring is put back in the holder and the panels can be closed again. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
Therefore avoid open heating systems or steel pipe 6.2. Safety device When working with higher temperatures by a bivalent have to be installed on sit pump operation can cause damage! operation can cause damage!. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
(without separating plate) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! point switch and an additional humidity sensor have to be installed.
AERO ILM Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! point switch and an additional humidity sensor have to be installed.
(with separating plate) (regulated) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! One heating circuit can be regulated as standard.
(with separation plate ) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! dew point switch has to be installed to monitor the dew point.
(with separating plate) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! The start of the oil-/gas burner is done by the potential-free contact for the 2.
(without separating plate) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! point switch and an additional humidity sensor have to be installed.
(with separating plate) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! One heating circuit can be regulated as standard.
(without layer separation plate) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! One heating circuit can be regulated as standard.
(with separation plate ) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! One heating circuit can be regulated as standard.
Mount the dew point switch on a suitable location. Throttle valve M 22 M 73 Hygienik 2.0 (with separation plate) Cooling buffer AERO ILM HGL sensor and a dew point switch has to be installed to monitor the dew point. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
In cooling mode it is possible to recover the waste heat. If installing heat recovery in cooling mode, there have to be set an additional piping for the HGL- return. HGL-return for heat recovery (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
For electrical details see the wiring diagram. Primary current electric immersion heater AERO ILM 4-13 3x400V/50Hz - 5G1,5 mm² AERO ILM 2-7 1x230V/50HZ - 3G6,0 mm² or 3x400V/50Hz - 5G1,5 mm² Primary current compressor AERO ILM 4-13 3x400V/50Hz - 5G4,0 mm²...
The sensor cables which have to be installed on site, have to be feed through the grommet on the right side. (C) IDM Energiesysteme GmbH Installation instruction AERO ILM...
(all other sensors are optional depending on the contact thermostat is required. The safety shutdown of the charge pump operates in this case directly via the heat pump. The sensor lines must be laid separately (C) IDM Energiesysteme GmbH Installation instruction AERO ILM...
Together with the lines of the energy supply companies, of transmission equipment and other communication facilities §electromagnetic pollution” that is invisible for us is created. (C) IDM Energiesysteme GmbH Installation instruction AERO ILM...
An annual inspection and maintenance of the system 8.1. Information regarding the start-up by customer service is recommended, in particular Before starting up the IDM heat pump ensure water with regard to protecting the guarantee claims. tightness on the heating side, rinse the heat pump...
9. 9. 9. Start-up 9. General description Genera Genera 9. Appendix 9.1. AERO ILM 2-7 - Performance data heating - detailed outdoor temperature [°C] W 35 °C heat capacity [kW] 10,65 10,52 10,38 9,90 8,91 6,56 6,19 5,61 4,78 4,30...
3) To ensure the minimum cooling output rate of distribution system, appropriate zones have to remain open A35/W18. Minimum cooling consumption 5.1 kW To ensure a large cooling demand, the cooling limit has to be set as high as possible. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...