VIPEDIA-12 Fault Codes for V2000

Table 2
V2000 Frame Faults
System
Fault Code(s)
Fault LED
(VIPEDIA-12 front
panel Faults
menu)
FRMXX AC
OFF
POWER
XX=Frame ID
FRMXX BATTERY
OFF
XX=Frame ID
FRMXX PSU
OFF
XX=Frame ID
FRMXX AUX
OFF
OUTPUT
XX=Frame ID
FRMXX CONFIG
OFF
XX=Frame ID
FRMXX NETWORK
OFF
XX=Frame ID
FRMXX OFF LINE
OFF
XX=Frame ID
FRMXX RESET
ON
XX=Frame ID
V2000 User's Manual
PATH/POWER/E
ARTH/FUSE
Fault Description
(bottom line of
LCD display)
POWER
Indicates a fault with the Mains
power.
MAINS front panel switch
turned off
Mains power lost
POWER
Indicates a fault with the
Battery power.
BATTERY front panel
switch turned off
Battery power lost
Battery voltage out of
range
Battery high temperature
Battery high impedance
POWER
Indicates a fault with the PSU
PCB board.
Aux voltage out of range
PSU high temperature
PSU comms fail
PSU fan fail
POWER
Indicates a fault with the
auxiliary DC output.
-
The V2000's static
configuration is missing or
corrupted or the V2000 frame
controller memory is faulty.
-
The V2000 lost Ethernet
connection to one or more
VIPEDIA-12 units that feed
audio to the V2000.
-
The DBB master VIPEDIA-12
has lost Ethernet comms to a
FRXX frame
-
An unexpected reset of the
V2000 frame controller CPU
has occurred (i.e. reset without
power cycling).
U-0623-0383.docx – Issue: 05 complete, approved – 17/12/15
Page 27 of 36
Suggested Action
Check mains power supply.
Check front MAINS switch.
Check battery power supply.
Check correct batteries fitted.
Check front BATTERY switch.
Check battery connection cables are
the correct length and diameter.
Fully power down the V2000, remove
the lid, and check the internal cabling.
Check the rack ventilation / cooling
and spacing above and below V2000
unit is correct.
Check audio load.
Check the fan is not obstructed.
If all seems ok, there may be an
internal fault with the unit's power
supply.
Check the auxiliary supply is not
overloaded (2A limit).
Re-upload the static configuration to
the V2000.
Replace the V2000 if repeated
occurrences.
Check the Ethernet network
connections of both units.
Check the DBB master VIPEDIA-12 is
operational (serdes member = 1)
Check the Ethernet network
connections of both units.
Check the V2000 frame is operational.
A one off occurrence may be
experienced due to EMI or transients.
Repeated occurrences indicate faulty
electronics.
Replace the V2000 if repeated
occurrences.