Receive : 0 1 06 00 65 00 02 18 14 ( e xample/hexadecimal )
This command means to send a code to the module and set the communication parameter as "9600, N (No check), 8, 1".This
setting could be saved when power off. The default communication parameter is "9600, N (no check), 8, 1". Attention is
required, when electing the correct communication parameter in communication setting and restarting the communication
terminal, setting will be done.Normally, the lower of baud rate, the lower of the transaction speed but the higher of transaction
stability. The opposite is also true.When module receives correct command, corresponding action will be taken and response
will be sent back to the master. This is successful communication.
6
I ndicator LED description
When module powered on, Led is green.
When module is under communication, LED is twinkling.
when module receive correct command, LED is green.
when module receive incorrect command or command for other modules, LED is red.
7
P C debugging instruction
This module provides software for parameter setting and function test. Please follow the steps below:
Connect the module and computer using RS485 converter.
Connect 12V or 24V power with module and power on.
positive & negative terminals are correctly connected before power on.
Open the software, select the correct module number, you will see the window of function test or parameter setting.
Set correct parameter, open communication interface.
Select corresponding setting, collection and control items.
WP9038ADAM User's Manual V1.42