Summary of Contents for EIT UV Power Puck II

  • Page 1 UV Power Puck II & UviCure Plus II User’s Guide Electronic Instrumentation and Technology (EIT) LLC 309 Kelly’s Ford Plaza SE Leesburg VA 20175 USA Phone: 703-478-0700 Email: uv@eit.com Web: www.eit.com EIT Part Number P/N IM-0111 Rev A Issued April 2019...
  • Page 2: Table Of Contents

    Maintenance – Cleaning and Calibration ..........................14 Cleaning-Display ................................14 Calibration ..................................14 EIT UV Instrument New Product and Calibration/Repair Warranty ................... 16 Appendix A: Optics Cleaning ............................... 17 Appendix B: Specifications ..............................19 Appendix C: Instrument Types and Software ........................20 Appendix D: Regulatory Statements ............................
  • Page 3: Introduction

    The UV Power Puck II and UviCure Plus II are self-contained, electro-optic radiometers that measure and display total UV energy and UV irradiance in a UV curing system. The UV Power Puck II and UviCure Plus II combine compact size and robust design to withstand the extremes of UV curing environments while providing accurate measurement.
  • Page 4: Operation And Features

    Examples of different functions are shown below. Examples of some of the different functions that will be shown under the instrument display EIT Part Number P/N IM-0111 Rev A Issued April 2019 Page 2...
  • Page 5 Above Right: Unit with Dynamic Range of 100 milliWatts Right: Power Puck II Profiler on Startup screen. See Appendix C for more information on the Profiler Versions of our instruments EIT Part Number P/N IM-0111 Rev A Issued April 2019 Page 3...
  • Page 6: Operating The Radiometer

    “ON / OFF” button) will exit the “RUN” mode and will return to the same default mode prior to making the exposure run, but will display the new value. EIT Part Number P/N IM-0111 Rev A Issued April 2019 Page 4...
  • Page 7 SAVE button to save the setting as the new default. An *asterisk will appear next to the setting. When changes are completed, press the EXIT button to return to the default mode. EIT Part Number P/N IM-0111 Rev A Issued April 2019 Page 5...
  • Page 8 TOGGLE (UviCure Plus II Only) – Pressing the SEL button, the user can “toggle” between the GRAPH and REFERENCE modes shown above. ALL CHANNEL (UV Power Puck II Only) – displays Joules and Watts for each of the four (4) UV bands (UVA, UVB, UVC, UVV) SMOOTH: There is a detailed discussion of SMOOTH in the Instrument Sample Rate section of the User’s Guide...
  • Page 9: Data Collection Techniques

    Double check and confirm the applied power and speed controller settings before taking a reading Applied power and speed controller settings are not always linear and can vary widely EIT Part Number P/N IM-0111 Rev A Issued April 2019 Page 7...
  • Page 10 Keep both the Joule and Watt values 9. Maintain Your Instrument • EIT instruments are calibrated on a six month cycle. The Power Puck II and UviCure Plus II can be used in harsh conditions including intense energy (UV, visible, infrared), temperature and coatings •...
  • Page 11 128-2048 Hz (samples per second) and the MicroCure a sample rate of 2048 Hz. The data (especially the irradiance value) collected and displayed EIT instruments can vary based on the: •...
  • Page 12 0.03 second section. It is clear that the power supply is cycling. The irradiance values shown are “Smooth Off” values at an effective sample rate of 2048 Hz. EIT Part Number P/N IM-0111 Rev A Issued April 2019 Page 10...
  • Page 13 The UviCure Plus II and Power Puck II ‘oversample’ at a very high sample rate. The user is able to adjust the effective sample rate to one of three settings in the set-up menu of the instrument. The effective sample rate is based on the Data (not Optical) Filter Bandwidth. EIT instruments use different bandwidths for the data filters.
  • Page 14 This rate (2048) also matches the sample rate on MicroCure radiometers “SMOOTH” PROFILER vs. PROFILER “INSTRUMENTS” EIT uses the term “PROFILER” to describe two separate instrument features. When PROFILER is used in the “SMOOTH” context, it refers to an effective sample rate of 128 Hz as described above.
  • Page 15: Diagnostics & Error Messages

    Diagnostics & Error Messages The UV Power Puck II and UVICURE Plus II continuously conduct internal self-diagnostics. If the unit detects an internal problem, it will display one or more of the following error codes in the upper left corner on the display. Error codes are two alphanumeric characters preceded by an *.
  • Page 16: Maintenance - Cleaning And Calibration

    Calibration EIT’s calibration period for the Power Puck II or UviCure Plus II is six months. This based on our historical data and experience. This data is a culmination of over twenty years of calibration experience. Most of these units are exposed to extreme environmental conditions and though they are very robust;...
  • Page 17 Service Request Form. When returning the UV Power Puck II or UviCure Plus II, please return the equipment in the original (or equivalent) packaging. You will be responsible for damage incurred from inadequate packaging, if the original packaging is not used.
  • Page 18: Eit Uv Instrument New Product And Calibration/Repair Warranty

    - any and all other expressed, implied, or statutory warranties or representations. This exclusion includes merchantability and fitness, as well as any and all other obligations or liabilities of EIT. EIT shall not be responsible for consequential damages resulting from malfunctions of the goods described in this manual.
  • Page 19: Appendix A: Optics Cleaning

    (wood manufacturing facility). Careful cleaning of the outer optics using these guidelines will help your EIT instrument perform as designed between service intervals at EIT. The guidelines are general and specific questions should be directed to EIT (uv@eit.com). Instruments that stop functioning when accidently dropped, get stuck in equipment or wind up covered or immersed with the product being cured need to come back to EIT for further evaluation.
  • Page 20 Hints 1. EIT strongly suggests the use of gloves to prevent the transfer of oils from your hand to the optics on the unit. 2. Each wipe is fresh and ready for use. The IPA in the wipe does not contain any detergents or surfactants and is not subject to being compromised from a cleaning of a previous instrument and/or other use in your facility.
  • Page 21: Appendix B: Specifications

    Cut polyurethane interior, scuff resistant nylon exterior cover/9 ounces (260 grams) Material/Weight Carrying Case 10.75 x 3.5 x 7.75 inches; 274 x 89 x 197 mm (W x H x D) Dimensions EIT Part Number P/N IM-0111 Rev A Issued April 2019 Page 19...
  • Page 22: Appendix C: Instrument Types And Software

    • More information on Profiler instruments is available from EIT or local EIT representative/distributor • Please contact EIT to see if your “Standard Version” instrument can be upgraded to a “Profiler Version” • Examples of PowerView III screens are below...
  • Page 23 Top: Start-up screen showing a puck-iiuvicure-plus-non-profiling-data-only-program Standard Version of the “Puck” Above: Instrument Display with all information Left: Screen display of the basic software program longer supported by EIT EIT Part Number P/N IM-0111 Rev A Issued April 2019 Page 21...
  • Page 24: Appendix D: Regulatory Statements

    EIT Products are Designed and manufactured in the USA. Electronic Instrumentation & Technology, LLC 309 Kelly’s Ford Plaza SE Leesburg, VA 20175 USA Telephone: 703-478-0700 Email Sales & Support: uv@eit.com Email Service: calibration@eit.com Web: www.eit.com EIT Part Number P/N IM-0111 Rev A Issued April 2019 Page 22...