Wiring - Pioneer PDP-502MX Service Manual

Hide thumbs Also See for PDP-502MX:
Table of Contents

Advertisement

PDP-502MX

7.1.3 WIRING

When forming the wire cables, be careful not to exert excessive
pressure on the cables as this will result in the disconnection of the
connectors.
Press-down type lower contact connector
1. Locking
Lock applying force in the arrow direction so that the connector
is pressed down inwards.
2. Unlocking
Push up with your nail, or something soft.
Do not use thin tools such as the tip of screwdrivers, because
they will damage the electrode.
Insert the flexible cables straight until the end.
Insert the flexible cable reinforcing plates in parallel to the
connectors. Moreover, insert the horizontal-connecting
connectors horizontally.
In connecting Address Modules and Cable Assy, and in
connecting Scan Modules and Y Drive Assy with the flexible
cables, hook both edges of the flexible cables on the connectors
and fix them, then close the covers.
Insert the flexible cables in parallel to the connector, otherwise
the connectors may be damaged.
1
Hook it on the
connector.
Address Module side
3
2
Pull it slightly
Note) When closing the connector cover, press both edges of the
cover by fingers to lock it. Pressing the center of the cover
may damage it.
88
Hook it on the
connector.
3
Notes
1) Bend the flexible cable between Y Drive Assy and Scan Module
at the Y Drive Assy side, and close the cover.
(To prevent damage of cover)
Connector
Y Drive Assy side
Bend so that the cable is horizontal
to Y Drive connector and then close
the cover.
Moreover, when
H6
V4 –1
are replaced in repair service, be careful of the way of bending.
H6
V4 –1
For
flexible cable, be careful that it does not touch
the chassis of FAN.
Y Drive Assy side
Scan Module side
J217
H9 – V4–4
How to bend the flexible cables
2) Place the cable between Digital Video Assy
E5
Assy
along the top of Shield Case of Digital Video Assy .
(To prevent noise)
3) Be careful of X Drive Assy and X Cable D Assy / X Cable U
Assy in repair service. Because, they are tightened together
with earth metal fittings being put between X Drive Assy and X
Cable D Assy, X Drive Assy and X Cable U Assy .
4) Be sure to wire between U-Com Assy CN3617 and Digital
Video Assy CN3283 with the grounding solid wire after repair
service.
Others (Attention to mis-wiring )
E5
If U-Com Assy
12pin and Digital Video Assy
are wired by mistake, the unit will not operate.
E28
If U-Com Assy
6pin and U-Com Assy
by mistake, the unit will not operate and the temperature sensor
may be damaged. Be sure to check the temperature sensor in the
case of mis-wiring.
Frexible Flat Cable
Connector
Scan Module side
and
H9
V4 –4
flexible cables
J214
H6 – V4–1
Y Drive Assy side
Scan Module side
D14
and U-Com
D17
12pin
E38
6pin are wired