OSO HOTWATER Super Xpress SX iQ Series Installation Manual

OSO HOTWATER Super Xpress SX iQ Series Installation Manual

Advertisement

Super Xpress - SX iQ
120-150-180-210-250-300 l.
EN
SAFETY INFORMATION
O&M INFORMATION
INSTALLATION MANUAL
TDS - TECHNICAL DATA SHEET
142228-02 - 08-2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Super Xpress SX iQ Series and is the answer not in the manual?

Questions and answers

Summary of Contents for OSO HOTWATER Super Xpress SX iQ Series

  • Page 1 Super Xpress - SX iQ 120-150-180-210-250-300 l. SAFETY INFORMATION O&M INFORMATION INSTALLATION MANUAL TDS - TECHNICAL DATA SHEET 142228-02 - 08-2019...
  • Page 2: Table Of Contents

    CONTENTS 1. General information 5. Safety and servicing 1.1 Product identification..........4 5.1 Safety cut out............16 1.2 CE Marking.............4 5.2 Intermittent discharge from tundish ..16 1.3 ErP data..............4 5.3 Continuos hot discharge from tundish . 16 1.4 General information ...........4 5.4 Expansion vessel maintenance ....
  • Page 3 Safety instructions uments where they are accessible for fu- • Read the following safety instructions ture reference. carefully before installing, maintaining or • The manufacturer assumes compliance adjusting the water heater. (by the end-user) with the safety, oper- • Personal injury or material damage may ating and maintenance instructions sup- result if the product is not installed or plied and (by the installer) with the fitting...
  • Page 4: General Information

    % kWh/a setting volume L OSO Hotwater AS 10802651 SX120 - 2.8kW @ 230V/3.0kW @ 240V iQ 38 1336 OSO Hotwater AS 10802652 SX150 - 2.8+2.8kW @230V/3.0+3.0kW @ 240V iQ 38 2670 OSO Hotwater AS 10802653 SX180 - 2.8+2.8kW @230V/3.0+3.0kW @ 240V iQ 40 2559 OSO Hotwater AS 10802654 SX210 - 2.8+2.8kW @230V/3.0+3.0kW @ 240V iQ...
  • Page 5: Handling

    1.5 Handling, location and positioning The product should be transported carefully as shown, with packaging. Use the handles in the box. CAUTION Tappings, valves etc. should not be used to lift the product as this could cause malfunc- tion. CAUTION The cylinder must be installed complying with current building regulations.
  • Page 6: Health And Safety Regulations

    2. INSTALLATION 2.1 Health and safety regulations Handling Operations Regulations 1992 defines Documentation supplied: manual handling as: “any transporting or support- • Installation manual & service logbook ing of a load (including the lifting, putting down, • Template for connecting pipework pushing, pulling, carrying or moving thereof by •...
  • Page 7: Preliminary Wiring

    2.7 Preliminary wiring Before final installation and pipe fitting it is recom- other. The table below shows the exact lengths mended to feed the electrical wires to the electri- these tails should be cut from wall to reach the cal box. The OSO Super SX is provided with two cylinder connections.
  • Page 8: Pipe Connections

    2.10 Pipe connections 2..15 Hot water outlet Before connecting the cold supply (3), flush the Connect the hot water distribution pipe to the cold supply pipework of all flux and debris. Lift off combination valve hot water outlet (see illustra- the cylinder lid to allow access to the combina- tion).
  • Page 9: Discharge Pipe

    3. COMMISSIONING 3.1 Commissioning and filling Check all connections for tightness. Open hot mostat settings to ‘smart -’ (if you require water water tap furthest away from the OSO water to remain at 70 an additional potable expan- heater. sion vessel is required) A secondary return can Open the mains stop cock to fill the water be connected via the expansion vessel connec- heater.
  • Page 10: Electrical Installation

    4. ELECTRICAL INSTALLATION 4.1 Immersion heaters Fork for upper immersion thermostat (ThermODisc) Power to immersion heaters should not be switched on until the unit is filled with water. All units are fit- ted with 2 no. 3 kW immersion heaters except SX 120 which has 1 no.
  • Page 11 One suitable treatment for the above point Treatment (OSO Hotwater recommends) is the use of DIN Power cable 46228-4 Tubular end-sleeves with plastic sleeves (commonly known as ferrules with insulation), with a conductor length of 12 mm as shown in the dia- gram (right).
  • Page 12: Smart Control Settings

    Further to the initial installation, end-users or install- Outline of thermostat ers may select a different position if the factory pre- when in position set position doesn’t meet hot water expectations. The factory default position, designated by a small ar- Thermostat probe row on the top cover, is the recommended position pocket...
  • Page 13: Smart Technology

    4.4 Smart Technology Smart Control for water heaters will save en- ergy and money for consumers by adapting the energy used to the typical household re- quirements for water heating. When the water heater is first switched on, the smart control Safety disk operates like a normal thermostat for 7 days, but during this time, will monitor and learn the...
  • Page 14: Smart Control Red Led Indicator

    4.6 Software Reset A software reset is required after any error 66 ±2 detection. To perform a software reset, switch the main power supply of the water heater off, select the vacation antifrost position and switch the power back on. After a software ±2 reset smart and comfort level can be selected by rotating the knob.
  • Page 15: Smart Control Technical Data

    4.10 Smart Control - Technical Data Items Description Product purpose Energy controller for Electric Storage Water Heater including thermal safety cut-off Product constructiom Hybrid control including electronic regulation and mechanical safety cut-out: 2-pole bimetal cut-out Terminal type Power terminals: screw pillar terminal Method of connection &...
  • Page 16: Safety And Servicing

    5. SAFETY AND SERVICING Maintenance must be carried out by a compe- vessel must be completely empty of water. if the tent person. pressure is different from the value shown on the label it must be restored to the original value. 5.1 Safety cut out Do not remove expansion vessel without depres- The safety cut-out operates if:...
  • Page 17: Drain Cock

    ting, the valve does not tighten, the seal is created external surfaces such as car parks, hard stand- by a double O-ring. To create the seal, the valve ings, grassed areas etc. are acceptable providing should be wound down until it will not go any fur- that where children may play or otherwise come ther, then wound back up less than one full turn into contact with discharges, a wire cage or simi-...
  • Page 18: Oso Fault Finding Guide

    6. OSO FAULT FINDING GUIDE Mains supply off Check and open stopcock No water from hot taps Strainer blocked Turn off water supply, remove and clean strainer Immersion heaters Check and switch on not switched on Cylinder thermal Water from taps Check and press reset button cutout has is cold...
  • Page 19: Technical Specification Commissioning And Service Logbook

    7. TECHNICAL AND PERFORMANCE SPECIFICATIONS Technical data - SX iQ Description Unit SX 120 iQ SX 150 iQ SX 180 iQ SX 210 iQ SX 250 iQ SX 300 iQ Part number 10802651 10802652 10802653 10802654 10802655 10802656 EAN number 7070644005894 7070644005900 7070644005917 7070644005924 7070644005931 7070644005948 Actual capacity of the water tank at 20°C Outer diameter of the tank...
  • Page 20 IT IS THE RESPONSIBILITY OF THE INSTALLER TO COMPLETE THIS LOG BOOK AND PASS IT ON TO THE CUSTOMER. FAILURE TO DO SO MAY INVALIDATE THE CYLINDER GUARANTEE The code of practice for the installation, commissioning & servicing of mains pressure hot water storage Installation,Commissioning and Service Record Log Book CUSTOMER DETAILS...
  • Page 21 (IF APPLICABLE) COMMISSIONING ENGINEER (IF DIFFERENT) DATE NAME ADDRESS TEL No. REGISTRATION DETAILS REGISTERED OPERATIVE ID CARD No. (IF APPLICABLE) APPLIANCE & TIME CONTROL DETAILS MANUFACTURER OSO HOTWATER (UK) MODEL litres CAPACITY SERIAL No. TYPE UNVENTED TIME CONTROL PROGRAMMER TIME SWITCH IT IS THE RESPONSIBILITY OF THE INSTALLER TO COMPLETE THIS LOGBOOK AND PASS IT ON TO THE CUSTOMER.
  • Page 22 COMMISSIONING PROCEDURE INFORMATION BOILER PRIMARY SETTINGS (INDIRECT HEATING ONLY) ALL BOILERS IS THE PRIMARY A SEALED OR OPEN VENTED SYSTEM? SEALED OPEN WHAT IS THE BOILER FLOW TEMPERATURE? ALL MAINS PRESSURISED SYSTEMS WHAT IS INCOMING STATIC COLD WATER PRESSURE AT THE INLET TO THE PRESSURE REDUCING VALVE? HAS STRAINER (IF FITTED) BEEN CLEANED OF INSTALLATION DEBRIS? HAS A WATER SCALE REDUCER BEEN FITTED?
  • Page 23: Service Interval Record

    GUARANTEE - OSO UNVENTED HOTWATER CYLINDER 1. Scope OSO Hotwater UK Ltd. (hereinafter called OSO) warrants for 2 • The immersion heater has not been exposed to hardness years from the date of purchase, that the Product will: i) conform levels exceeding 10°dH (180 ppm CaCO3).
  • Page 24 SERVICE 9 SERVICE 10 DATE: DATE: ENGINEER NAME ENGINEER NAME COMPANY NAME COMPANY NAME TEL No. TEL No. COMMENTS COMMENTS SIGNATURE SIGNATURE When all the above services have been completed, please contact OSO Hotwater for an additional service interval record sheet.
  • Page 25 Notes...
  • Page 26 Notes...
  • Page 27 Notes...
  • Page 28 OSO Hotwater (UK) Limited Endeavor House, Seventh Avenue, Team Valley Trading Estate, Gateshead, Tyne & Wear, NE11 0EF Phone: (0191) 482 0800 Fax: (0191) 491 3655 E-mail technical.uk@oso-hotwater.co.uk E-mail spareparts.uk@oso-hotwater.co.uk E-mail sales.uk@oso-hotwater.co.uk Manufactured by OSO Hotwater AS Industriveien 1 3300 Hokksund - Norway Tel.: +47 32 25 00 00...

This manual is also suitable for:

Sx 150Sx 180Sx 210Sx 250Sx 120Sx 300

Table of Contents