Standard or extended room air conditioner case

Advertisement

ELECTRICAL REQUIREMENTS (230/208V)
Provisions should be made to have the proper
electrical outlet near the case. All wiring should be
made in accordance with local codes and
regulations. The line cord included with the chassis
(if used) will extend to a wall receptacle located
within the area shown in tabulation below.
"A"
Inside
Model
AZ Series
Wall Receptacles
230V/208V 15 amp
230V/208V 20 amp
"tandem" type
"perpendicular" type
All wiring should be made in accordance with local
electrical codes and regulations.
See the Owner's Manual for how to connect
electrical supply.
Note:
Aluminum wiring in structure may pose special
problems—consult a qualified electrician.
ELECTRICAL REQUIREMENTS (265V)
Warning:
Connection of a 265V product to a branch circuit
MUST be done by direct connection to be in
compliance with the National Electric Code.
Plugging a 265V unit directly into a building
mounted exposed receptacle is not permitted by
code.
See the Owner's Manual for how to connect
electrical supply.
"B"
"A"
"B"
21"
58"
230V 30 amp
"tandem" type
Specifications subject to change without notice
A Quality Product of GE Appliances
DRAIN KIT
If it is necessary to install a drain kit on this wall
case, the following kit is available:
RAD10
Internal/External Drain
1. With an "Internal Drain", the condensate drain
tube must be connected to an internal drain
system in the building.
WALL CASE WITH RAD10 DRAIN UNIT
Steel mounting plate
Type "A" screws
2. With an "External Drain" (which may be connected
to a field supplied drain line) condensate water can
be drained away from the unit and building.
WALL CASE WITH RAD10 DRAIN UNIT
EXTERNAL DRAIN
Steel mounting plate
Type "A" screws
Note:
It may be desirable or necessary to install the
drain kit on the case prior to installing the case into
the wall.
4
INTERNAL DRAIN
See detail
below
Overflow relief drain
Square drain holes
Neoprene sponge gasket
Gasket
Speed nuts
Cabinet bottom
Tube
"
1/2
O.D.
Cover plate
Type "A" screws
Overflow relief drains
Square drain holes
1/2" O.D. drain tube
Neoprene sponge gasket
SCREW
Type "A"
METAL
Alternate
6" long, 1/2"
O.D. straight
copper tube.