7.11
Wiring diagram
BLACK
PI
BLACK
BROWN
L
N
BLUE
CN11
EAR
L
N
F
TRA
PI
V
EAR
EV
SM
To connect the "Air Thermostat" or, alternatively the "Remote Control", remove the bridge
between terminals 5-6.
m
CAUTION
Users must:
– Use an omnipolar cut-off switch, disconnect switch
in compliance with AS/NZS Standards
– Respect the connections L (Live) - N (Neutral)
– Ensure that the special power cable is only replaced
with a cable ordered as a spare part and connected
by professionally qualified personnel
– Connect the earth wire to an effective earthing
system. The manufacturer is not responsible for any
damage caused by failure to earth the appliance or
failure to observe the information provided in the
wiring diagrams.
20
SAUX
SE
1
2
3
4 5 6
EV
CN12
CN13
CN14
F
CD. 6302285
TRA
Line
Neutral
Fuse (3.15AT)
Ignition transformer
System pump
Fan
Ignition / Detection electrode
Gas solenoid valve
Delivery sensor
CR
TA1
TA2
CN15
CN3
CN5
CN6
SAUX
TS
TFU
SF
TPA
TA1-TA2
SE
d
IT IS FORBIDDEN
To use water pipes for earthing the appliance.
BLUE
BROWN
TPA
RED
SF
RED
TS
SM
TFU
Auxiliary sensor
Safety thermostat
Thermal fuse
Smoke flue gas probe
Pressure transducer
Air thermostat
External sensor
V
4 3 2 1
Fig. 15
Need help?
Do you have a question about the BRAVA SLIM HE R Series and is the answer not in the manual?
Questions and answers