  • Page 1 INSTRUCTION MANUAL Hot Air Station without Extractor desk Ref. JTSE-QA...
  • Page 2: Packing List

    Ref. PH218 Ref. JN2015 JN2012 JN2020 Kapton Tape ....1 unit Power cable ....1 unit Manual .......1 unit Ref. PH217 Ref. 0009417 (100V / 120V) Ref. 0018814 0009401 (230V) www.jbctools.com INSTRUCTION MANUAL Hot Air Station without Extractor desk Ref. JTSE-QA...
  • Page 3 w w w.jbctools.com Features USB-A connector Thermocouple type K Activates the suction pump Heating element Hot Air button (On / Off) Suction Tube For tripods and extractors Heater Hose set Ref. JT-T1A (100V/120V) JT-T2A (230V) Stand Ref. JT-SE Auxiliar connector Equipotential connector USB connector Robot RS232 connector...
  • Page 4 JTSE / TESE Work Screen The JTSE/TESE offers an intuitive user interface which provides quick access to station parameters. Default PIN: 0105 Status bar 17:14 Status indicator 4m 38s Instant power supplied to Hot Air Temp. Air Flow Selec. heater ºC Current Selected...
  • Page 5: Advanced Functionalities

    w w w.jbctools.com Advanced functionalities To work with profiles it is essential to use the RWB / RWS / RWT rework arms. The Rework Arms supports the Hot Air Heater maintaining the distance and position to the component. Profiles In this mode you can set up or edit as many as 25 profiles of temperature and air flow. Profile name 3m 18s Hot Air Temp...
  • Page 6: System Notifications

    Insert a USB flash drive into the USB-A connector to save your soldering process in csv format. Files Station update Download the JBC Update File from www.jbctools.com/software.html Insert the USB flash drive with the file down- loadedto the station. Update System notifications The following icons will be displayed on the screen’s status bar.
  • Page 7: Adjustable Stand

    w w w.jbctools.com Adjustable Stand Adjust the tool holder angle to suit your work position. Operation Modes 1. From the Tool Settings Menu, select the mode to activate the tool depending on the task. Tool button Pedal* Press Press Press the start/stop button to blow hot air. Press the Pedal to blow hot air and release to stop.
  • Page 8: Operation

    Operation 1. Placing 2. Heating 3. Extracting Position the extractor with the Heat the component. The component lifts off appropriate suction cup and automatically when the press the suction button. solder melts. Protectors & Extractors For small components For large components (fig.
  • Page 9 w w w.jbctools.com Using the Thermocouple type K Connect a TC type K (PH218) to the station and use it as a protection or regulation sensor. You can define its use mode by means of the “Ext TC mode” option in the “Tool” menu. You can choose from two work modes: Regulation: the station regulates the air Protection: the station cuts the air supply off...
  • Page 10 Quick Nozzle Changer Changing nozzles quickly and safely. Turn the tool off and handle with care. The heating element and the nozzle are still hot. Compatible Nozzles The JT-TA works with JT nozzles. Find the model that best suits your soldering needs in www.jbctools.com Ref.
  • Page 11: Replacing The Heating Element

    w w w.jbctools.com Replacing the Heating Element Only perform this operation when the element is cold and the unit is disconnected from the mains. 1. Loosen the screw. 2. Pull the heating element out of the handle. 3. Connect the new heating element, ensuring it is pushed all the way in. 4.
  • Page 12: Maintenance

    If necessary use a tool to lever it off. and return it to the station. Fuse Fuse holder Fuse holder - Replace any defective or damaged pieces. Use original JBC spare parts only. - Repairs should only be performed by a JBC authorized technical service.
  • Page 13 w w w.jbctools.com Safety It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion. - Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire. - The power cord must be plugged into approved bases. Make sure that it is properly grounded before use.
  • Page 14 有害物质含量表 产品中有害物质的名称及含量 有害物质 部件名称 六价铬 多溴联苯 多溴二苯醚 铅(Pb) 汞(Hg) 镉(Cd) (Cr(VI)) (PBB) (PBDE) 烙铁头 手柄 电源线 主机 电源插座 保险丝 主开关 电位连接 变压器 线路板 O 表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572 规定的限量要求以下。 X 表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 26572 规定的限量要求。...
  • Page 15: Specifications

    w w w.jbctools.com Specifications JTSE-1A 100V - 120V 50/60Hz. Input fuse: 8A. Rated current: 7A JTSE-2A 230V 50/60Hz. Input fuse: 4A. Rated current: 3A - Nominal power: 700W - Temperature selection: Room temp. / 150 - 450 °C (300 - 840 °F) Cool mode: T off.
  • Page 16 In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase. This product should not be thrown in the garbage.