110 - 230 V AC (CSA) (Part No.: 1 690 7010)
18 - 36 V DC (CSA) (Part No.: 1 690 7011)
ATTENTION
Maximum relay contact loading: 2 Ampere
6

Commissioning

The safety instructions in the previous sections must be observed!
Before commissioning, the unit should be checked and a functional test carried out. Particular attention should
be paid to the following:
Have the electrical connections been carried out in accordance with regulations?
Have the thermal sensors/limiters been connected?
Is the seal monitoring device (where fitted) correctly installed?
Is the motor overload switch correctly set?
Have the power and control circuit cables been correctly fitted?
Has the motor connection cable been laid in such a manner that it cannot be caught up by the rotating body?
Has the minimum submergence level been observed? (See Section 1.7 Dimensions and weights).
36
Connect terminal 3
to ground or housing
of the RW/RCP
Figure 30. Electronic amplifier with collective signalling
Power Supply
CA 461
3
4
5 6
Output
Input
Leakage