Soleus Air LX-140 NT Operating Instructions Manual
Soleus Air LX-140 NT Operating Instructions Manual

Soleus Air LX-140 NT Operating Instructions Manual

Dual hose portable air conditioner with heat pump, 14,000 btu cooling, 11,500 btu heating

Advertisement

4010450
Air conditioner must be upright for 24 hours prior to operating.
V180320
This ensures that the compressor will function as intended.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LX-140 NT and is the answer not in the manual?

Questions and answers

Summary of Contents for Soleus Air LX-140 NT

  • Page 1 4010450 Air conditioner must be upright for 24 hours prior to operating. V180320 This ensures that the compressor will function as intended.
  • Page 2: Purchase Information

    PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner’s Manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner.
  • Page 3: Package Contents

    Remote Control (1) Window Kit Panel (3) AAA Battery (2) Window Kit Adapter (2) Owner’s Manual (1) SPECIFICATIONS Model Number LX-140 NT Capacity Cool/Heat 14,000 BTU/11,500 BTU Dehumidification 126 pts/Day Cooling Power Usage 1350 Watts / 11.9 Amps Heating Power Usage 1150 Watts / 10.2 Amps...
  • Page 4: Power Cord And Plug

    POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexi- ble cord with no termination on the load side and a LCDI attachment plug on the line side. The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
  • Page 5: Product Diagram

    PRODUCT DIAGRAM Intake hose connector 16. Remote Control & Battery...
  • Page 6: Parts & Assembly

    PARTS & ASSEMBLY WINDOW VENTING KIT *The two hoses' size are different ASSEMBLY & INSTALLATION When the unit is operating in air conditioning mode, the unit draws in indoor air and exhausts hot air out of the room to complete the air exchange. The Window Kit must be installed when operating the unit in air conditioning, dehu- midification and heating modes.
  • Page 7: Window Kit Assembly

    WINDOW KIT ASSEMBLY 1. Using Panel B to connect Panel A & C by placing the Wing Nut Base on Panel A & C. 2 Tighten the Wing Nuts after adjusting the length of the panel according to the height of the window. 3.
  • Page 8: Window Kit Installation

    WINDOW KIT INSTALLATION PORTABLE AIR CONDITIONER The window venting kit must be installed in order for the unit to work correctly. The window venting kit has been de- signed to fit into most vertical and horizontal window openings and sliding glass doors up to 7 feet. *The window kit included with your purchase may vary slightly from what is shown below.
  • Page 9: Control Panel

    CONTROL PANEL Power Heat Mode Air Conditioner Indicator Fan Speed Indicator Timer Mode Indicator Indicators Indicator Fan Mode Dehumidifier Indicator Bucket Full Mode Swing Function Sleep Mode Indicator Indicator OPERATING INSTRUCTIONS FOR CONTROL PANEL BUTTONS 1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off.
  • Page 10: Remote Control

    REMOTE CONTROL LCD DISPLAY POWER BUTTON FAN SPEED TIMER/TEMP INCREASE MODE BUTTON TIMER BUTTON SWING BUTTON TIMER/TEMP DECREASE SLEEP MODE BUTTON...
  • Page 11 REMOTE CONTROL 1) Power On and Off - When the unit is plugged in, press the POWER button to turn on the unit. Press the POWER button once more to turn the unit off. When in Air Conditioner mode and Heat mode the selected temperature will appear on the remote control LCD display.
  • Page 12: Unit Operation

    UNIT OPERATION Air Conditioner Mode 1) Install the exhaust hose and window kit properly (see pages 7&8). 2) Plug the Power Cord into an electrical outlet. 3) Turn on the unit by pressing the POWER button. 4) Press the Mode button until the air conditioner mode indicator lights up on the control panel display. 5) Press the until the desired room temperature appears on the control panel display.
  • Page 13 UNIT OPERATION Fan Mode 1) Plug the Power Cord into an electrical outlet. 2) Turn on the unit by pressing the POWER button on the control panel. 3) Press the MODE button until the fan mode indicator lights up on the control panel display. 4) Select the fan speed by pressing the FAN button.
  • Page 14: Maintenance

    MAINTENANCE BUCKET FULL INDICATOR When the Internal Water Tank is full, the Bucket Full light will illuminate and the unit will automatically shut down. The air conditioner will resume normal operation once Internal Water Tank is emptied. INTERNAL WATER TANK When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to evaporate some of the moisture fast enough.
  • Page 15 MAINTENANCE HOW TO DRAIN THE INTERNAL WATER TANK *You will need a small pan, approximately 1” high to catch the water coming out of the water tank. Once the water tank is empty, the unit will resume operation within a few minutes. 1.
  • Page 16 MAINTENANCE NOTE: Make sure power is off and the power cord is not plugged into an electrical outlet prior to perform- ing any maintenance on the unit Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed.
  • Page 17: Troubleshooting

    TROUBLESHOOTING PROBLEM CAUSE SOLUTION • Plug unit in. • Unit is not plugged in • Check electric breaker box for a Air conditioner does not • No electric current to outlet trip power on • Internal safety device has tripped •...
  • Page 18: Self-Diagnosis

    SELF-DIAGNOSIS CODES SELF-DIAGNOSIS The unit has a self diagnosis system to identify a number of malfunctions. Error codes are displayed on the appliance display. Error Code Possible Causes Solution Turn the unit on and off to remove error code. Pipe Temperature Sensor Failure If this code appears again, please call customer service at (877)-976-5387 Turn the unit on and off to remove error code.
  • Page 19: Limited Warranty

    Five Year Compressor Limited Warranty SoleusAir West warrants the accompanying Soleus Air Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year for compo- nents and FIVE (5) years for the compressor from the date of original retail purchase in the United States.

Table of Contents