Appliance Start Up; Temperature Control Programming; Programming Set Temperature; Additional Controller Functions - Pitco TB-SRTG Installation & Operation Manual

Floor gas rethermalizer
Table of Contents

Advertisement

TB-SRTG: Gas Floor Model Rethermalizer

2.3. APPLIANCE START UP

Refer to the following procedure to start the appliance prior to operation.
1. Ensure that the drain valve is closed.
2. Fill the cook tank with water. (See section 2.1 "Filling the Appliance")
3. Light the appliance. (See section 1.9.2 "Lighting Instructions")
4. Turn the ON/OFF (I/O) switch, to the ON (I) position.
NEVER operate the appliance with an empty cook tank. It may void the warranty.
Adding water after the heat tubes have been heated may cause injuries from hot
splattering liquids and steam.
5. The appliance's controller may need to be turned on. Press the
controller on.
*The specified button may appear slightly
different then shown. Refer to the operator's
manual for your appliance's specific control
type to determine the exact appearance of each
button and display.
6. The appliance is now on and heating the water
in the cook tank.

2.4. TEMPERATURE CONTROL PROGRAMMING

A jumper wire must be installed between terminals +5 and –3
on the back of the controller. Controller is non-programmable
without the wire installed.
2.4.1.

PROGRAMMING SET TEMPERATURE

Press
(Set Temperature mode – Set Temperature is
programmed using this function).
Press
Press
will not adjust to desired setting, check the HI and LO temperature settings).
Press
2.4.2.

ADDITIONAL CONTROLLER FUNCTIONS

Some controllers have additional functions not described in this manual. If your appliance's
controller has additional functions, refer to the controller's operation manual to access these
functions.
WARNING
, display shows "SP1"
, display shows "XXX", where XXX = current set temperature.
buttons to change the temperature setting. (NOTE: If set temperature
, to save the new temperature setting.
L20-376, rev. 1 (08/18)
OPERATION
* button to turn the
WARNING
Water must completely cover the heat
tubes at all times while appliance is on.
Dry fired heat tubes are extremely hot,
will shorten its service life and may
void your warranty.
Rethermalizer Digital Thermostat