Calibrator
______________________________________________________________________________
Calibrator Security Levels
Which personalities and status items which can be viewed on the Calibrator is restricted using
passwords. There are three levels of Calibrator access. These are shown in the table below:
Access Level
Text
Service
Ser
Engineering
Eng
All Adjust
All
Note, in Service or Engineering mode, only items appropriate to the current system configuration
are displayed. For example, if lift switch 5 is not configured, then the Speed personality will not
be displayed for that switch. In All Adjust mode, all items are shown regardless of configuration.
The password can only be entered just after power up when the Pump Hours Counter is displayed.
The ' +' and ' -' buttons are used to enter the password. The first digit is entered by pressing the ' +'
button the appropriate number of times (i.e. once to enter 1). The second digit is entered by
pressing the ' -' button the appropriate number of times (i.e. 6 times to enter 6). The third digit is
entered using the ' +' button again and the final digit is entered using the ' -' button again. Note that
when the ' +' or ' -' buttons are pressed, the display still changes to show hours or 1000 x hours.
When the password has been completely entered press either the ' +' button or the SELECT button
to initiate verification. If the password has been entered correctly, the text shown in the table
above appropriate to the required level will be displayed for 1s indicating the password was
accepted. If the password was incorrect or no password was entered, the system always defaults to
Service mode.
After the Security Level has been displayed, the system enters the normal menu structure shown
in the Calibrator Map. To change the password level, you need to recycle the Keyswitch.
MillipaK PUMP Controller Manual
Password
Default. This level is selected when no password or an
-
invalid password is entered. Only items shown in the
Calibrator Map with a thick solid border are displayed.
Only items shown in the Calibrator Map with a thick or
1645
thin solid border are displayed.
Contact
All items are displayed.
SEVCON
Page 11
Calibrator/Security Levels
Description
07/11/05
Need help?