AEG for each mission with multiple functions. Give your AEG a new lease of life! Configure your TITAN in the field or simply update the firmware and adjust the settings using the USB-Link and the GATE Control Station app which is available for PC/MAC and Android devices.
The Product Warranty Form is also available there: https://www.gatee.eu/technical-support/warranty GATE Enterprise spółka z ograniczoną odpowiedzialnością sp. k. does not take any responsibility for damages, injuries and accidents resulting from the use of this product or the use of Air Electric Gun with the product installed. In case you have any difficulties while installing or using this product, we recommend to contact us.
Warning Stay careful to prevent short circuiting the battery as the consequences can be very dangerous (fire, battery explosion, burn). 2.2. Installation Warning Before starting installation process, please ensure that your AEG is empty and there are no BBs inside. Caution The incorrect installation may result in sensors’...
Page 6
Notice TITAN V2 and V3 do not support the Infinite torque-up gears. TITAN V2 NGRS supports the Infinite torque-up gears. Notice Do not use too much grease. Excessive grease may cover gaps between teeth what will cause improper cycle detection.
USB-Link. Notice Check the availability of TITAN firmware updates using the most recent GCS app: https://www.gatee.eu/gcs . Using the most recent firmware versions ensures stable functioning of the device and allows for taking advantage of all its features.
Page 8
Caution The device covers must not be removed by the user (e.g. foil or heat shrink tube). Notice Avoid using your device near strong electromagnetic fields or when electrostatic discharges such as lightening occur in the atmosphere.
It enables access to the Statistics and TITAN World Rankings. In order to upgrade your TITAN firmware from BASIC to ADVANCED, you need to purchase the upgrade. Follow the steps on the website: www.gatee.eu/editions or use GCS App for Android...
Furthermore, TITAN V2 and TITAN V2 NGRS are divided in two types. Depending on where you keep the battery, you can choose between FRONT and REAR wiring. TITAN V3 has one universal type of wiring. If you have battery in buttstock, you can use additional buttstock extension.
Page 14
Case 3 1. Do you have USB-Link? NO. 2. Do you prefer ADVANCED firmware or BASIC firmware edition? BASIC. 3. You should buy TITAN Basic Module and USB-Link separately. Case 4 1. Do you have USB-Link? YES. 2. Do you prefer ADVANCED firmware or BASIC firmware edition? BASIC.
GATE Control Station enables you to simply update the firmware and adjust the settings using the USB-Link and the GATE Control Station™ app. Thanks to the GCS, you do not have to remember complicated trigger sequences to program your unit. All the features are easily accessible and simple to adjust with just one click.
Page 16
GATE Control Station screen. USB-Link has a 4-colour LED indicator. BLUE (glowing) The USB-Link is connected to a PC or smartphone. TITAN is not connected or a PC driver is not installed. You can download the driver here: www.gatee.eu/drivers BLUE (blinking) The USB-Link does not have an installed firmware.
Page 17
The USB-Link is connected to TITAN and PC, MAC or smartphone. GREEN (blinking) The USB-Link is connected to TITAN and PC, MAC or smartphone, but the TITAN does not have an installed firmware. Please install the TITAN firmware. YELLOW (glowing) The USB-Link is transmitting data.
Now you can control TITAN via GATE Control Station. During the first start you will be asked to create your own profile. It is not obligatory but it will help when you will be contacting our support. 5.2. Status tab ...
Info - basic legal information 5.3. Settings tab Settings tab was created in order to simplify the configuration of your TITAN. Factory reset – (also called “Hard reset”) restores all default settings, resets your statistics and clears adaptation data.
Page 20
Settings tab: Fire selector mode – allows you to choose how your replica will behave on each fire selector position: • SAFE – replica will not fire after trigger pull • SEMI – one pull of the trigger will result in only one shot •...
Page 21
Cycle detection – allows to switch OFF or ON the optical gear sensor. Cycle detection OFF can be compared with the “emergency mode” for troubles with gear sensor. Most of TITAN features will be disabled, but you can still shoot on ‘AUTO’.
Regional lock designed for German players will disable all the burst and auto options. Notice The DSG and 19-TOOTH gear ratio options are not available for TITAN V2 NGRS. 5.4. Sensors tab Depending on your TITAN model, you will see one of the three screens below.
Page 23
We designed the Sensors TAB in order to let you choose the trigger sensitivity or trigger mode that is the best for you. Thanks to live view, you do not need to mechanically adjust your trigger. Simply choose the value and check if it suits you. You will be warned if the trigger sensitivity value reaches extremely low level.
The statistics tab contains main information about your replica performance. You can simply clear each value by clicking “Reset” button. You can also independently reset BB1 and BB2 counter. TITAN gives you the option to check: • Rate of fire - Minimum, Average, Maximum • Trigger response - Minimum, Average, Maximum •...
5.6. Diagnostic Trouble Codes (DTC) tab This TAB will help you to troubleshoot your replica in case of any issue. If you need additional help, you can contact our Support Center using “SEND REPORT” button, or save the report ...
TITAN V2 TITAN V2™ is an AEG Control System for V2 gearboxes which will transform your AEG into an advanced training weapon. Adjust your AEG and check the Statistics using USB-Link and GATE Control Station app for PC/MAC and Android devices. Gain a tactical advantage thanks to the extremely fast trigger response, option of adjusting trigger sensitivity to your preferences and many other useful functions.
The ADVANCED firmware edition offers wide variety of functions and is dedicated for those who like complex solutions. It enables access to the Statistics and TITAN World Rankings. To learn all the differences between firmware editions, please check the comparison table.
6.2. TITAN V2 Basic Module The best if you long for having TITAN in two or more airsoft guns. Then you do not need the second USB-Link from the Advanced or Complete set. It includes TITAN with BASIC firmware edition.
Stay careful to avoid this damage. Caution Gearbox shell manufactured by ICS and Krytac must be modified to achieve 100% compatibility with TITAN V2. Lack of the modification will permanently damage your unit, which is not covered by the warranty.
Page 31
Caution Placing the washers in wrong order will cause short circuit and permanent damage to the TITAN, which is not covered by the warranty.
Page 32
Caution The improper placement of wiring under motor gear can cause insulation damage and a short circuit. Caution Do not pull the trigger when gearbox is open. It may result in trigger sensors’ damage. Notice In case of some triggers (e.g. speed or CNC triggers), first trigger sensors might be covered even if the trigger is not pulled.
Page 33
Notice A selector sensor does not detect black surface. If your selector does not have metal connector, you must use sticker from the kit. Notice The sticker position is very important. Pay attention to place the sticker very close to the left edge, between the top and bottom red lines. The set contains 3 different sticker types.
• grease • USB-Link, micro USB-Cable and PC / MAC or OTG cable and Android device Follow the steps below in order to mount the TITAN drop-in module: Remove the gearbox from the AEG body. Disassemble your gearbox, take out all the internals.
Page 35
Pay attention to the marked area. If you see that it is not smooth, use a metal file or grindstone to prepare the surface. The gearbox surface should be smooth, with no sharp edges which would damage the TITAN. Detach the drop-in module carefully.
Page 36
Place the bottom board on the bottom part of the gearbox. Do not use a screw yet. Check if the bottom board is laid flat in the gearbox. Make sure the electronic components do not touch the gearbox case.
Page 37
Use the insulation (black) washer from the kit. ATTENTION! The insulation washer must protect the circuit board. The metal screw and metal washer cannot touch the board directly. It can result in a short circuit and TITAN damage which is not covered by the warranty.
Page 38
10. Check if the screw sticks out of the gearbox. 11. If so, add metal washer(s) included in the kit. Make sure that the metal washer is placed between the screw and the insulation washer. It cannot touch the circuit board directly.
Page 39
12. Check if the top board fits gearbox without any problems. 13. Loosen the screw. Adjust the position of the bottom board. The distance between the board and the bearing should be similar as indicated in the marked area.
Page 40
Notice Sector gear sensor placement is very important. 14. Make sure the marked areas are not covered by board or wires.
Page 41
15. Check if sensors are clean and not covered by wires. 16. Some gearboxes need modification. Check if your gearbox has the marked pins. If so, remove them.
Page 42
17. Check if both parts of the gearbox fit together perfectly. 18. Mount the trigger without spring. Insert the TITAN top board. Close the gearbox. When the gearbox is closed, carefully check if the trigger moves smoothly and does not touch any TITAN’s components.
Page 43
19. Mount the sector gear, trigger with spring and top TITAN board. Make sure that the gear does not touch TITAN. 20. Close the gearbox. Tighten two screws on the top part of the gearbox case.
Page 44
21. Prepare selector plate. If the selector plate does not have copper connector, you need to modify it. The black surface does not reflect light, so sensors cannot work properly. 22. In order to modify the black plate, use a sticker from the installation kit.
Page 45
23. Black plate after modification. The sticker location is very important. It should be as close to the left side as possible. 24. Install the selector plate.
Page 46
25. Connect TITAN to your PC using USB-Link. Start the GATE Control Station App. 26. Pull the trigger slowly. The TRIGGER SENSORS LED indicators will stop glowing, one by one. They indicate active sensors. In case of some trigger models,...
Page 48
27. Check if the sensors recognize the selector plate. Moving the selector plate, verify if TITAN detects SAFE, SEMI and AUTO. 28. If all the three LED indicators are ON, this means an error.
Page 49
Then you need to cover the sensors. 29. Turn the gear slowly to check if the sensor detects teeth. Keep in mind that the TITAN reads the sensors much quicker than the GCS.
Page 50
In a critical situation, excessive grease may cover a sensor. Notice A few initial shots are ‘calibration shots’. TITAN adapts to the gearbox configuration. In order to readapt TITAN, you must restore factory settings or change gear ratio. This is necessary e. g. if you replaced motor...
7. TITAN V3 TITAN V3™ is an AEG Control System for V3 gearboxes which will transform your airsoft gun into an advanced training weapon. Adjust your AEG and check the Statistics using USB-Link and GATE Control Station app for PC/MAC and Android devices. TITAN V3 enables you to adjust the trigger sensitivity with military precision.
7.1. TITAN Advanced Set At once you purchase all you need to take total advantage from TITAN. It includes TITAN with ADVANCED firmware edition. The ADVANCED firmware edition offers wide variety of functions and is dedicated for those who like complex solutions. It enables access to the Statistics and TITAN World Rankings. To learn all the differences between firmware editions, please check the comparison table.
7.2. TITAN Basic Module The best if you long for having TITAN in two or more airsoft guns. Then you do not need the second USB-Link from the Advanced set. It includes TITAN with BASIC firmware edition. The BASIC firmware edition is an economic version with limited number of functions, dedicated for those who prefer simplicity but require highest quality.
The TITAN V3 fits CNC gearboxes with very small backlash. While fitting the TITAN, pull the cables and at the same time push the board into the right place. Pay attention to the area marked in yellow to fit the board correctly.
Page 55
Use the trigger sticker to make it visible for trigger sensor. Notice TITAN detects trigger position very precisely. In order to use it, you need to eliminate trigger backlash. The set contains 3 trigger anti-backlash stickers of different thickness. Try each of them and choose the most proper one.
Notice The selector plate requires modification. Place the selector sticker according to the photos below. Notice The sticker position is very important. 7.4. Installation Installation kit contents: 1. Selector plate stickers (3 pcs) 2. Trigger stickers (6 pcs) 3. Connectors set 4.
Page 57
• grease • USB-Link, micro USB-Cable and PC / MAC or OTG cable and Android device Follow the steps below in order to mount the TITAN drop-in module: Remove the gearbox from the AEG body. Disassemble your gearbox, take out all the internals.
Page 58
Clean the gearbox case using solvent. Detach the drop-in module carefully.
Page 59
Route the wires through gearbox shell from the inside. Place the wires in gearbox shell so as the unit can fit properly without any resistance.
Page 60
Place the bottom board on the bottom part of the gearbox. Do not use a screw yet. Check if the bottom board is laid flat in the gearbox. Make sure the electronic components do not touch the gearbox case.
Page 61
If the bottom board fits correctly, use a cut-off lever screw to stabilize the unit. Use also the included washers. Notice TITAN V3 does not require an insulation washer. 10. Check if the screw sticks out of the gearbox.
Page 62
11. If so, add metal washer(s) included in the kit. 12. Check if the top board fits gearbox without any problems.
Page 63
13. Loosen the screw. Adjust the position of the bottom board. The distance between the board and the bearing should be similar as indicated in the marked area. Notice Sector gear sensor placement is very important.
Page 64
14. Mount the sector gear and top TITAN board. Make sure that the gear does not touch TITAN. 15. Close the gearbox. Use at least two screws.
Page 65
16. Connect TITAN to your PC through USB-Link. Start the GATE Control Station App. 17. Turn the gear slowly to check if the sensor detects teeth. Keep in mind that the TITAN reads the sensors much quicker than the GCS.
Page 66
18. Use solvent to clean trigger elements. Next, paste the smaller sticker (trigger sticker) on the flat surface. 19. Paste one trigger anti-backlash sticker inside the moving element of the trigger.
Page 67
Notice The stickers reduce space between the trigger and the moving element, so as the trigger works more precisely. Installation kit includes three stickers of different thickness. 20. After pasting the first sticker, assemble both trigger elements and estimate the clearance between them.
Page 68
Do not use too much grease. In a critical situation, excessive grease may cover a sensor. 22. In some replicas (G36, UMP, etc.) you need to modify the mechanical trigger lock, because it is too long and touches the TITAN top board. In this case, grind the protruding element by around 1.5/2mm [0.06/0.08 in].
Page 69
23. After the modification, check if the mechanical trigger lock touches the TITAN top board. If it does not touch the board, you can take the next step. 24. Install the remaining external gearbox components and start the wiring placement.
Page 70
25. Prepare the selector plate following the steps below. If the plate is a standard one (AK, most of G36, etc.), paste the sticker like in the picture below. If necessary, enlarge the hole in the plate - space between the selector plate border and the sticker border should be approximately 10mm [0.4 in].
Page 71
27. Finish the gearbox assembly and put it in the replica body. Next, connect TITAN to PC using USB-Link and perform the sensor calibration following the calibration instructions from GATE Control Station. Caution Calibrate the trigger and selector sensors only after the gearbox is mounted in the...
8. TITAN V2 NGRS TITAN V2 NGRS™ is an AEG Control System for Tokyo Marui V2 Next Generation Recoil Shock gearboxes. Transform your Tokyo Marui Next Generation AEG into an advanced training weapon system. Adjust your weapon and check the Statistics using USB-Link and GATE Control Station app for PC, MAC and Android devices.
The ADVANCED firmware edition offers wide variety of functions and is dedicated for those who like complex solutions. It enables access to the Statistics and TITAN World Rankings. To learn all the differences between firmware editions, please check the comparison table.
Quickstart Guide 8.2. TITAN Basic Module The best if you long for having TITAN in two or more airsoft guns. Then you do not need the second USB-Link from the Advanced or Complete set. It includes TITAN with BASIC firmware edition.
Basic Module contents: 1. TITAN V2 NGRS with BASIC firmware edition (rear or front wired) 2. Installation Kit 3. Quickstart Guide Notice TITAN V2 NGRS supports: Tokyo Marui M4 Next Generation Tokyo Marui SCAR-H Next Generation Tokyo Marui SCAR-L Next Generation...
Page 76
Caution Placing the washers in wrong order will cause a short circuit and permanent damage to the TITAN, what is not covered by the warranty. Caution Do not use a cut-off lever screw to secure the TITAN board.
Page 77
The sticker position is very important. Notice In case of TITAN V2 NGRS pre-cocking setup via fire selector is different than in case of TITAN V2, due to presence of mechanical trigger safety lever. In order to set the pre-cocking: 1.
8.4. Installation Installation kit contents: M2 steel washer (2 pcs) M2 pressboard washer (2 pcs) Selector plate sticker (6 psc) Female deans-t connector Male deans-t connector 4.8mm x 12mm [0.19in x 0.47in] black heat-shrink tube (2 pcs) 4.8mm x 12mm [0.19in x 0.47in] red heat-shrink tube (2 pcs) 3.2mm x 18mm [0.13in x 0.71in] black heat-shrink tube 3.2mm x 18mm [0.13in x 0.71in] red heat-shrink tube 10.
Page 79
• grease • USB-Link, micro USB-Cable and PC / MAC or OTG cable and Android device Follow the steps below in order to mount the TITAN drop-in module: Remove the gearbox from the AEG body. Disassemble your gearbox, take out all the internals.
Page 80
Clean the gearbox case using solvent. Detach the drop-in module carefully.
Page 81
Place the bottom board on the bottom part of the gearbox. Do not use a screw yet. Check if the bottom board is laid flat in the gearbox. Make sure the electronic components do not touch the gearbox case.
Page 82
Use the insulation (black) washer from the kit. ATTENTION! The insulation washer must protect the circuit board. The metal screw and metal washer cannot touch the board directly. It can result in short circuit and TITAN damage what is not covered by the warranty.
Page 83
Check if the screw sticks out of the gearbox. 10. If so, add metal washer(s) included in the kit. Make sure that the metal washer is placed between the screw and the insulation washer. It cannot touch the circuit board directly.
Page 84
11. Check if the top board fits gearbox without any problems. 12. Make sure the marked areas are not covered by board or wires. Check if sensors are clean.
Page 85
13. Place the wires in the gearbox shell, in exactly the same way as in the picture. The order is important. 14. Check if both parts of the gearbox fit together perfectly.
Page 86
15. Mount the sector gear and top TITAN board. Make sure that the gear does not touch TITAN. 16. Close the gearbox. Tighten at least three screws.
Page 87
17. Connect the unit with GATE Control Station using USB cable and USB-Link (do not solder Deans-T connectors yet). 18. Go to Sensors TAB. While moving the gear, observe what happens with the FULL SECTION/HALF SECTION icons and gear sensors. Please note that...
Page 88
19. Depending on the position of the gear, the FULL SECTION/HALF SECTION icons should flash alternately. The gear sensors should also flash alternately. 20. Test the bolt catch sensor by moving the lever up and down. Observe what happens with the BOLT CATCH SENSOR icons. Depending on the position of the lever, the icons should flash alternately.
Page 89
21. If both sensors work flawlessly, you can assemble the gearbox. Do not use too much grease. In a critical situation, excessive grease may cover a sensor. 22. Modify the fire selector plate. Use solvent to clean fire selector plate. Next, take the stickers shown in the picture below.
Page 90
24. The wires in buffer tube have to be placed according to the photos below.
Page 91
Warning Pay attention to correctly solder positive and negative TITAN wires to the connector. Otherwise, after plugging the battery, the reverse battery polarity will cause immediate damage to the device. Is not covered by the warranty and it can lead to fire, burn or even battery explosion.
Page 92
25. Put heat-shrink tube on a wire, cover the connector with a thin layer of solder (always use flux or rosin during soldering, especially when solder melts. This is necessary to achieve the correct connection). 26. Have a look at the connection and check if it is done properly. Pay attention to solder –...
Page 93
27. Repeat the procedure with black (negative) wire. 28. Prepare the heat-shrink tubes and close them. Heat each heat-shrink tube carefully from all sides. Do it over the flame of a gas range or lighter.
Page 94
29. If your gun is completely assembled, perform the sensor calibration. Go to Sensors TAB in GATE Control Station and calibrate the trigger. 30. Then calibrate the fire selector. 31. After successful calibration your AEG is ready to use.
TRIGGER SENSITIVITY ADJUSTMENT Trigger sensors allow you to control trigger sensitivity. You do not have to disassemble your AEG. Just use the GATE Control Station app to adjust the trigger to your preferences and level of skills. CONFIGURABLE FIRE SELECTOR (gen.2)
Page 96
There are two PRE-COCKING MODES: • AUTO MODE – the spring is automatically compressed after each shot • TRIGGER MODE – slow trigger action compresses the spring, and fast trigger action fires the shot. There are also three PRE-COCKING BOOST options: HIGH / MID / LOW. *Now the pre-cocking is fully operational in SEMI, BURST and AUTO modes and there is no need to set the pre-cocking boost manually.
Page 97
The microprocessor monitors the battery voltage constantly. When the voltage drops down to a critical level, it will not allow firing. *TITAN detects the number of cells automatically. There is no need to reprogram TITAN every time you replace the battery.
Page 98
As a result, you gain a higher ROF of the gun and a faster trigger response. BUILT-IN SELF-TEST This allows you to quickly check whether the TITAN is working properly. If any problem occurs, the Diagnostic Trouble Codes will indicate where the problem lies.
Page 99
PRINTED QUICKSTART Make your adventure start more easily with a new product. The quickstart contains basic information and hints. TRIGGER SENSITIVITY Allows you to adjust the trigger to your preferences and level of skills. 30-ROUND LIMIT An AEG can continuously fire max. 30 BBs. To fire more BBs, you must release the trigger before.
EXCLUSION OF LIABILITY GATE Enterprise spółka z ograniczoną odpowiedzialnością sp. k. is not liable for any damages, injuries or accidents of any kind resulting from the use of this product or airsoft gun with the product installed, including (but not limited to) incidental or special damages to airsoft gun, airsoft gun parts, batteries and gearbox internals.
CERTIFICATE OF CONFORMITY GATE TITAN V2, GATE TITAN V3, GATE TITAN V2 NGRS and GATE USB-Link are in conformity with the essential requirements of the following Directives: EC DIRECTIVE 2011/65/EU. The products have been certified as RoHS Compliant.
Need help?
Do you have a question about the Titan and is the answer not in the manual?
Questions and answers