ICP DAS USA I-7080 Quick Start Manual

ICP DAS USA I-7080 Quick Start Manual

2 channel counter / frequency input data acquisition module
Hide thumbs Also See for I-7080:

Advertisement

I-7080
2 Channel Counter / Frequency Input Data
Acquisition Module
Quick Start Guide
Product Website:
https://www.icpdas-usa.com/_data_acquisition_i_7080.html
http://www.icpdas-usa.com/dcon_utility_pro.html

1. Introduction

I-7080 is intelligently designed to provide signal conditioning system monitoring and safe value
settings. I-7080 is a cost-effective solution for a wide range of valuable industrial control signals
and systems. The DCON utility can help users to configure and test I-7080 High Speed Counter /
Frequency Input module. Plenty of library functions and demo programs are provided to let
users develop programs easily under Windows, Linux and DOS operating systems. The
communication interface is modbus protocol via RS-485. Users may mount the modules on a
DIN rail, panel or wall. Modules have a screw-terminal block to connect to the signals.

2. Terminal Assignment

I-7080 2 Ch Counter / Frequency Input DAQ Module - QuickStart (Apr/2017)
ICP DAS USA, Inc. |
www.icpdas-usa.com
| 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the I-7080 and is the answer not in the manual?

Questions and answers

Summary of Contents for ICP DAS USA I-7080

  • Page 1 I-7080 is a cost-effective solution for a wide range of valuable industrial control signals and systems. The DCON utility can help users to configure and test I-7080 High Speed Counter / Frequency Input module. Plenty of library functions and demo programs are provided to let users develop programs easily under Windows, Linux and DOS operating systems.
  • Page 2 • data=1 start+8 data+1 stop(no parity) • type=50 (counter input) • alarm=hi alarm on counter 0 & counter 1 (I-7080) I-7080 2 Ch Counter / Frequency Input DAQ Module - QuickStart (Apr/2017) ICP DAS USA, Inc. | www.icpdas-usa.com | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717...
  • Page 3 3. Connect the module to the power supply using the +Vs and GND terminals. Note that the voltage supplied should be in the range of +10 to +30V DC. I-7080 2 Ch Counter / Frequency Input DAQ Module - QuickStart (Apr/2017) ICP DAS USA, Inc. | www.icpdas-usa.com...
  • Page 4 The default settings for the module can be found in Section 3. Click OK after selecting the COM port setting. I-7080 2 Ch Counter / Frequency Input DAQ Module - QuickStart (Apr/2017) ICP DAS USA, Inc. | www.icpdas-usa.com...
  • Page 5 DCON Utility Pro supports DCON and Modbus protocol for all ICPDAS and the others modules. 6. Configuration I/O module setting on PC I-7080 2 Ch Counter / Frequency Input DAQ Module - QuickStart (Apr/2017) ICP DAS USA, Inc. | www.icpdas-usa.com...
  • Page 6 If user doesn’t know command, user can select Address and ID, it will show some refer commands as below. User can select necessary command to test or debug modules. I-7080 2 Ch Counter / Frequency Input DAQ Module - QuickStart (Apr/2017) ICP DAS USA, Inc. | www.icpdas-usa.com...