PEDESTAL FIXING

IEC60335-2-41 TEST standard requires the filter pump to be
vertically fixed on ground or a certain pedestal made of wood or
concrete before use. There should be two holes 9mm in
diameter on the pedestal, the space between which should be
159mm. Put filter pump on the pedestal and fix them together by
fasten the bolts and nuts. All the pedestal parts should weigh
over 18kgs at least to prevent the pump from accidentally falling.
NOTE: It is imperative to check that the hydraulic connectors are not closed.

Operation

1) Open/unscrew the Air Purge Valve (P6112) on the top of the Filter Pump; air is released as water fills the Filter Pump.
2) When water comes out of the Air Purge Valve (P6112) screw it closed and wipe away any water.
3) To start the Filter Pump, insert the plug into a residual current device (RCD).
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP - Make sure both the
pool's Inlet and Outlet valves are fully covered by water before operating the
Filter Pump.

Maintenance

CAUTION: YOU MUST ENSURE THE FILTER PUMP ISUNPLUGGED
BEFORE ANY MAINTENANCE OR STORAGEB EGINS OR SEVERE
RISK OF INJURY OR DEATH EXISTS.
1) Unplug the Filter Pump.
2) Loosen the Hose Clamps on the pool's Inlet and Outlet Hoses by unscrewing the fly nut counter-clockwise.
3) Remove Debris Screens from the inside of the pool.
4) Replace the Debris Screens with the Stopper Plugs in the pool's Inlet and Outlet Valves.
5) Unscrew the Filter Cap Retainer and remove the Filter Cap.
6) Clean the Filter Cartridge with a garden hose, if filter cartridge remains soiled or discolored, it is necessary to replace it with a new one.
7) Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
8) Check that the Filter Cap Seal is in place.
9) Replace the Filter Cap and screw the Filter Cap Retainer into position.
10) Replace the Stopper Plugs with the Debris Screens in the pool's Inlet and Outlet Valves. Tighten the Hose Clamps. Water will now flow to the pump.
11) Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.
IMPORTANT: For sanitary reasons we suggest replacing the Filter Cartridge
with a new one every two weeks.

STORAGE

1) Unplug the Filter Pump.
2) Follow the instructions as previously outlined to stop water flowing to the Filter Pump and to remove the Filter Cartridge.
3) Discard the Filter Cartridge.
4) Detach all Hoses.
5) Dry all components thoroughly.
6) Store the filter pump in a dry location out of the reach of children. Storage temperature: 4-40°C (39.2-104°F)

Pump Warranty

For information concerning pump warranty please visit our website at: www.bestwaycorp.com
A
A
B
5
2-M8 nut
2-M8 bolt
B
S-S-004225

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FlowClear 58383 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF