Inhep Digital Security IDS 1200 Installer Manual

Alarm panel

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDS 1200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Inhep Digital Security IDS 1200

  • Page 2 IDS1200 INSTALLER MANUAL Summary of Operation & t i t + [! ! ! ! ! ] + [! ! ! ! ! ] + + [! ! ! ! ! ] + + [! ! ! ! ! ] + + [! ! ! ! ! ] + IDS1200 INSTALLER...
  • Page 3: Table Of Contents

    IDS1200 INSTALLER MANUAL Contents Introduction to the IDS1200.................... 5 1.1 Features ..........................5 Installation and Wiring ....................5 End-of-Line Resistors/Tamper per Zone ..............6 Connecting the Telephone Communicator ..............7 Programmable Outputs ....................8 The Key-Switch or Remote Control Unit ..............8 Additional Technical Data ....................
  • Page 4: Table Of Contents

    IDS1200 INSTALLER MANUAL Tables Table 1: Value represented by each zone indicator ............10 Table 2: Binary Representation ..................... 10 Table 3: Location / Zone Defaults ..................12 Table 4: Programmable Zone Types ..................13 Table 5: Standard Contact ID reporting codes ..............20 Table 6: Alarm reporting codes....................
  • Page 5: Introduction To The Ids1200

    IDS1200 INSTALLER MANUAL 1. Introduction to the IDS1200 is a versatile, state of the art, microprocessor based, twelve zone alarm panel. Most features IDS1200 are optional and may be programmed either directly through the keypad or via the telephone system, using download software and appropriate modem.
  • Page 6: End-Of-Line Resistors/Tamper Per Zone

    IDS1200 INSTALLER MANUAL Figure 1: Connection Diagram - without tamper per zone Dialler Board IDS1200 Connection Diagram LINE TELKOM EARTH EARTH LINE PHONE Keypad DOOR LED Position of Dialler Zone 12 Board Zone 11 Zone 10 Hardware Zone 9 Reset Zone 8 Switch P.I.R.
  • Page 7: Connecting The Telephone Communicator

    IDS1200 INSTALLER MANUAL If the zones are programmed to report tamper by zone, the 4K7 and 12K end-of-line resistors should be connected as per Figure 2 below. The 4K7 and 12K resistors are not included with the panel but may be obtained from your local distributor of IDS products.
  • Page 8: Programmable Outputs

    IDS1200 INSTALLER MANUAL 5. Programmable Outputs A relay board must be used when any device requiring a high current (>50mA) is connected to a programmable output. The current sink and source capability is the same for outputs 1-5. The output circuitry consists of a 12 volt source with a 56Ω...
  • Page 9: Hardware Reset Switch

    IDS1200 INSTALLER MANUAL The panic zone provided on the keypad is not an end-of-line supervised zone and requires a normally open panic switch. If using this panic zone connect a normally open panic switch between the PAN terminal and the GND terminal. If this zone is not used leave the terminal open circuit. A door LED may be connected to the keypad.
  • Page 10: Programming Instructions

    IDS1200 INSTALLER MANUAL 10. Programming Instructions 10.1 Introduction The panel may be programmed either using the keypad or using the up/download software. Programming the panel by means of the keypad is explained in the following sections of this manual. For information on programming the panel using the up/download software refer to the manual pertaining to the software.
  • Page 11: Programming The Panel

    IDS1200 INSTALLER MANUAL shown in the table below. 10.3 Programming the Panel For all programming procedures, the [! ! ! ! ! ] (star) key functions as the enter key and the [#] (hash) key functions as a clear key to clear incorrect or unintended entries, as a back space and to exit the programming mode.
  • Page 12: Program Location Summary

    IDS1200 INSTALLER MANUAL 10.4 Program Location Summary Following is a detailed description of the functioning of each location and its options. l l a t l u t l u . t s e t l l l i t l u t l u f n i l l i...
  • Page 13: Table 4: Programmable Zone Types

    IDS1200 INSTALLER MANUAL Table 4: Programmable Zone Types t a l t i x t i x t a l t i x t i n t i x t i t u l i t i x t i x f I .
  • Page 14 IDS1200 INSTALLER MANUAL t l u When this option is disabled an entry/ exit delay is allowed when arming and disarming. This means that follower zones may be violated and the entry/ exit zone may be opened and closed during the entry and exit delay times, provided that these zones are clear at the end of the arming time.
  • Page 15 IDS1200 INSTALLER MANUAL t i t l l i y l l t l u t i x . i ( t i x l l i t i t l l i t i x t i t l l i t i x The stay mode allows the user access to certain pre-programmed “stay”...
  • Page 16 IDS1200 INSTALLER MANUAL If the panel is programmed to report to two different base stations (dual reporting), it will continue to dial each of the numbers until it has transmitted the information to both (or the maximum number of dial attempts is reached).
  • Page 17 IDS1200 INSTALLER MANUAL t i t . n i . n i . n i . n i . n i ) t l . n i . n i . n i . n i NB: See Location 933 for Partition 2 secondary entry delay (Page 35). The secondary entry delay applies to the secondary entry/ exit zone.
  • Page 18 IDS1200 INSTALLER MANUAL If the power should fail, the panel will wait for this period of time before reporting the mains failure to the base station or logging the event to the event log. If the power is restored after the time out period has ended the same time out period will apply before the restoral event is reported and logged.
  • Page 19 IDS1200 INSTALLER MANUAL ) t l This option enables a delay before reporting an event. The delay time is programmed into location 31. If the delay is enabled the following events will not be reported if a user code is entered during the delay: Zone violation Zone Tampering Panic Zone Violation...
  • Page 20: Table 5: Standard Contact Id Reporting Codes

    IDS1200 INSTALLER MANUAL NOTE ON DUAL REPORTING If dual reporting is enabled both base stations will receive all programmed reporting codes. NOTES ON CONTACT ID. If the panel has been programmed to use the Contact ID reporting format (i.e. location 32=6) it is not necessary to program the reporting codes.
  • Page 21: Table 6: Alarm Reporting Codes

    IDS1200 INSTALLER MANUAL Table 6: Alarm reporting codes / y r t i x EXAMPLE Assuming for a given installation if differentiation is required between entry/exit, interior and general burglary zones, and assuming that zone 1 is a front door (entry/exit zone), zone 2 is an interior (interior zone) and zone 3 is a general burglary zone.
  • Page 22 IDS1200 INSTALLER MANUAL Some pager systems may require a termination digit/s to be communicated. These termination digits inform the pager network that the message is complete. Any required termination digits must be programmed into locations 671 and 672. Enter [11] for a “!” and [12] for a “#”. A [0] in these locations will be ignored. To achieve the above it may be necessary to join the 2 phone numbers to create a single number i.e.
  • Page 23 IDS1200 INSTALLER MANUAL When using either of the blind formats (i.e. Domestic Reporting or Pager Format), where no handshake is received, the number will be dialled and the data will be transmitted the number of times as programmed into the number of dial attempts (location 674). l a i ) t l l a i...
  • Page 24 IDS1200 INSTALLER MANUAL EXAMPLE Assuming a phone number consisting of an area code 031, a 4 second pause and a phone number of 705 1373 These locations contain the secondary telephone number that may be up to sixteen digits long. The same procedures apply as for the Primary Telephone Number.
  • Page 25 IDS1200 INSTALLER MANUAL Enter [10] into location 67. Enter [1] into location 68. Enter [4] into location 69. Communicator Reporting Codes (Locations 70 - 649) With the exception of Contact ID and Sescoa Superfast, all other communications formats are 4x2 reporting formats i.e.
  • Page 26 IDS1200 INSTALLER MANUAL A zone bypass code will be reported if the panel is armed with a bypassed zone. If the panel is armed and a violation of a zone occurs followed by the zone returning to the normal (non alarm) state, a zone violation followed by a zone restoral will be reported.
  • Page 27 IDS1200 INSTALLER MANUAL This code is the test reporting code and will be reported at regular intervals as programmed into location 764. Reporting of this code is recommended as it provides verification that the system is functioning correctly. This code will be reported when a download has been successfully performed. If the panel experiences trouble with its 12V auxiliary power supply, or if the Aux.
  • Page 28 IDS1200 INSTALLER MANUAL t i t NB: See Locations 958-959 for Partition 2 Keypad Lockout reporting codes (Page 36). This code will be reported if multiple attempts are made to disarm partition 1 using the wrong user code. The code will be reported after the programmed number of user codes (location 1298) required to initiate keypad lockout have been entered.
  • Page 29: Table 8: Location Default Values (Loc. 675 - 679)

    IDS1200 INSTALLER MANUAL Select a value from the table below. Table 7: Programmable Output Program Values The strobe and fire-detect outputs may only be programmed with a [0], [1], [2], [3], [4] or [5] i.e. the function is assigned to an output. Table 8: Location default values (Loc.
  • Page 30: Table 9: Location Default Values (Loc. 683 - 694)

    IDS1200 INSTALLER MANUAL light (or any other device requiring power) is connected to a programmable output, a relay board must be used to provide the high current. Please refer to the Section 5 Programmable Outputs. Table 9: Location default values (Loc. 683 - 694) t i n u l i l i a...
  • Page 31: Table 11: Location Descriptions (Loc. 708 - 712)

    IDS1200 INSTALLER MANUAL ) t l . n i . n i . n i . n i . n i . n i . n i . n i . n i Each auxiliary output can be programmed to have a different pulse time. The factory default time for all outputs is 3 seconds.
  • Page 32 IDS1200 INSTALLER MANUAL ) t l The time period between auto-test reports is programmed using this location. The time period is incremented in 24 hour increments with the shortest time period being 24 hours which relates to a value of 1. The maximum value which may be programmed into this location is 15.
  • Page 33 IDS1200 INSTALLER MANUAL This location programs the number of rings before the panel picks up the telephone line and attempts to up/ download. In the event that the panel picks up the phone and no valid download log on sequence is received by the panel, the call will be terminated by the panel after 40 seconds.
  • Page 34 IDS1200 INSTALLER MANUAL t i t . n i . n i . n i . n i . n i ) t l . n i . n i . n i . n i NB: See Location 21 for Partition 1 exit delay (Page 16). This is the period of time allowed for exiting before the panel arms.
  • Page 35 IDS1200 INSTALLER MANUAL t i t . n i . n i . n i . n i . n i ) t l . n i . n i . n i . n i NB: See Location 23 for Partition 1 secondary entry delay (Page 17). The secondary entry delay applies to the secondary entry/ exit zone.
  • Page 36 IDS1200 INSTALLER MANUAL The four digit account code for the telephone communicator is programmed into these locations. The panel/ partition is identified at the receiver by this account number. The account code must be four digits long. Any account number shorter than four digits must be preceded with “10”s.
  • Page 37: Table 12: Location Default Values (Loc. 960 - 964)

    IDS1200 INSTALLER MANUAL t i t SEE: LOCATIONS 675-679 for Partition 1 Programmable Output Controls (Page 28). These locations control the functioning of the 5 onboard programmable outputs. If a smoke detector, strobe light (or any other device requiring power) is connected to a programmable output, a relay board must be used to provide the high current.
  • Page 38 IDS1200 INSTALLER MANUAL The keypad can be programmed to provide an audible indication of a trouble condition. The keypad will sound intermittently. The [#] key will cancel the beeping. For a list of trouble conditions consult the user manual. ) t l If telephone line monitoring is enabled, and the panel is armed and the line voltage drops below 9V for more than 20 seconds, the siren will sound.
  • Page 39 IDS1200 INSTALLER MANUAL ) t l If a zone is programmed as a Silent Instant Zone, the alarm will be silent regardless of the value programmed into this location. ) t l This location only affects a panic condition that is initiated by the Panic key on the keypad [P]. The action of a panic condition caused by violation of a panic zone will depend upon whether it is programmed as an audible or silent panic zone.
  • Page 40 IDS1200 INSTALLER MANUAL Enter the number of times a zone must be violated during an arm cycle before being bypassed. This location is only active if the swinger shutdown has been enabled. ) t l When enabled, this locations allows that after a programmable number of violations during an armed cycle a zone will be automatically bypassed.
  • Page 41 IDS1200 INSTALLER MANUAL ) t l When enabled, this location allows the panel to arm without an exit delay when a keyswitch or remote control unit is used. ) t l When enabled, this location allows the panel reset switch to be used to default the panel. When the reset switch has been disabled, the panel can only be defaulted by entering [0] into location 0.
  • Page 42 IDS1200 INSTALLER MANUAL ) t l When enabled, entering the master user code in either partition will arm or disarm depending on the current state of the partition the code is entered from. When arming, the partition from which the system is armed will arm in either the stay or away mode, depending on how it has been programmed or whether an entry/ exit zone has been violated.
  • Page 43 IDS1200 INSTALLER MANUAL t l u / y r t i x o l l y t i / y r t i x t i t t i x t i t t i t t i t t i t l l a l a i n i l...
  • Page 44 IDS1200 INSTALLER MANUAL t i t t i t t i t t i t t i t IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 45 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 46 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 47 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 48 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 49 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 50 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 51 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 52 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 53 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 54 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 55 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 56 IDS1200 INSTALLER MANUAL l i a l i a t i t . t r . t r . t r . t r . t r . t r . t r . t r . t r . t r .
  • Page 57 IDS1200 INSTALLER MANUAL l a i . t r . t r . t r . t r . t r u l i l i a l a i . t r . t r . t r . t r .
  • Page 58 IDS1200 INSTALLER MANUAL . t r . t r . t r IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 59 IDS1200 INSTALLER MANUAL . t r . t r . t r IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 60 IDS1200 INSTALLER MANUAL IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 61 IDS1200 INSTALLER MANUAL t i t t i t . t r . t r IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 62 IDS1200 INSTALLER MANUAL t i t . t r t i x . t r . t r . t r . t r . t r IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18...
  • Page 63 IDS1200 INSTALLER MANUAL t i t . t r . t r . t r . t r t i t . t r . t r . t r . t r . t r . t r . t r .
  • Page 64 IDS1200 INSTALLER MANUAL t i n t i n l l a l l a l l a l l a t a l c t i / e l c t i g i l s f f / e l l i a &...
  • Page 65 IDS1200 INSTALLER MANUAL Index AC Fail ............................26, 30 AC Fail & Restore Time ......................... 17 AC Power ..........................9, 18, 26 AC Restoral ............................26, 30 Account Code ........................21, 22, 24, 35 Partition 1 ............................35 Partition 2 ............................35 ..........................
  • Page 66 IDS1200 INSTALLER MANUAL Dialling Pulse ............................16 Tone ............................16 Disarming ........................20, 28, 36, 37 Domestic Reporting ......................... 22, 23 Download Software ......................5, 9, 10, 32, 39 DTMF ............................21 Dual Reporting ........................5, 15, 16, 20 Duress Code ..........................27, 30, 35 End-of-Line Resistor .......................
  • Page 67 IDS1200 INSTALLER MANUAL AC Restoral Reporting Code ......................26 Arming with Entry/ Exit Zones Violated ..................... 15 Audible Alarm ............................ 38 Audible Keypad Panic ........................38 Auto-test Delay ..........................31 Auto-test Reporting Code ........................27 Auto-test Time ..........................31 Aux. 12V Trouble Reporting Code ..................... 27 Battery Restoral Reporting Code .......................
  • Page 68 IDS1200 INSTALLER MANUAL Partition 2 Keypad Fire Reporting Code .................... 35 Partition 2 Keypad Lock Out Reporting Code ..................36 Partition 2 Keypad Medical Reporting Code ..................36 Partition 2 Keypad Panic Reporting Code ................... 35 Partition 2 Keypad Tamper Reporting Code ..................36 Partition 2 Primary Entry Delay ......................
  • Page 69 IDS1200 INSTALLER MANUAL Switch .............................. 9 Panic Key ..........................27, 35, 38 Partition ................5, 7, 8, 13, 14, 15, 18, 24, 33, 35, 39 ..............13, 16, 18, 24, 27, 28, 30, 32, 33, 34, 35, 36 ................. 13, 18, 24, 27, 28, 30, 31, 32, 33, 35, 36 Programmable Outputs ..................
  • Page 70 IDS1200 INSTALLER MANUAL Entry/ Exit ....................12, 13, 15, 16, 21, 33, 34 Primary ......................13, 16, 17, 34 Secondary ........................17, 34 Follower ......................12, 13, 14, 16, 33, 34 Home .............................. 9 Instant ..........................13, 16, 34 Priority/ Panic ........................ 5, 7, 8, 9, 38 Silent Instant ..........................