M400 is an electro-mechanical actuator for the control of
two-way and three-way plug valves in:
heating systems
air handling systems
M400 is primarily designed for applications where the
demands on actuator speed and thrust are small.
The actuator can not be equipped with Self Testing
Device STS.
M400 is either controlled by an increase/decrease signal
or by a modulating 2–10 V control signal.
The electronic circuitry of the actuator ensures that the
running time is the same, regardless of the stroke of the
valve in question.
It is easy to mount and connect the actuator. It can be
mounted directly onto TAC's control valves, without any
mounting kit.
The working range of the actuator is adjusted
automatically depending on the stroke of the valve. The
electronic circuitry of the actuator then takes care of the
adjustment of the valve end positions.
The actuator is supplied by 24 V AC. It can provide
16 V DC voltage supply for older TAC controllers.
TECHNICAL DATA, M400
Part numbers ....................... see the table on the next page
Supply voltage ............................ 24 V AC ±10%, 50–60 Hz
Power consumption ........................................ average 6 VA
Transformer sizing ...................................................... 30 VA
Running time:
Modulating .................................................................. 60 s
Increase/decrease ............................................ 300 s/60 s
Stroke ........................................ 10–32 mm (0.39 - 1.26 in.)
Factory set stroke ................................... 20 mm (0.79 in.)
Thrust ............................................................. 400 N (90 lbf)
Duty cycle .......................................... max. 20%/60 minutes
Analog input:
Voltage .................................................................. 0–10 V
Impedance ..................................................... min 100 kΩ
Digital inputs VH–VC:
Voltage across open input .................................. 24 V AC
Current through closed input .................................... 5 mA
Pulse time ....................................................... min. 20 ms
Output G1:
Voltage ..................................................... 16 V DC ±0,3 V
Load ......................................... 25 mA, short-circuit proof
We reserve the right to make minor changes.
TAC Forta
M400
Actuator for Valves
Output Y:
Voltage ................................................... 2-10 V (0-100%)
Load ......................................................................... 2 mA
Ambient temperature:
Operation ............................ –10 – +50 °C (14°F - 122°F)
Storage ................................ –10 – +50 °C (14°F - 122°F)
Ambient humidity ............................................ max. 90% RH
Enclosure rating ........................................................... IP 54
Standards:
Emission ............................................... EN 50081-1:1992
Immunity ............................................... EN 50082-1:1992
Heat ................................................................. IEC-68-2-2
Humidity .......................................................... IEC-68-2-3
Cold ................................................................. IEC-68-2-1
Salt mist ........................................................ IEC-68-2-11
Vibration .......................................................... IEC-68-2-6
Material:
Housing ............................................................ aluminium
Cover ........................................................ ABS/PC plastic
Color ........................................................... aluminium/black
Weight .......................................................... 1.8 kg (3.96 lb)
Dimensions .................... refer to the table on the next page
1 (6)
G-40-22
11 Jun 2003
0-003-2060-1 (EN)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Forta M400 and is the answer not in the manual?

Questions and answers

Summary of Contents for TAC Forta M400

  • Page 1 The actuator is supplied by 24 V AC. It can provide 16 V DC voltage supply for older TAC controllers. TECHNICAL DATA, M400 Part numbers ....... see the table on the next page Output Y: Supply voltage ......
  • Page 2: Part Numbers

    PART NUMBERS Designation Explanation Part number M400 modulating control signal or increase/decrease signal 880-0230-020 M400-S2 modulating control signal or increase/decrease signal and end point switches 880-0231-020 DIMENSIONS (6.81) (4.60) Mått: mm Dimensions: (in.) (1.73) Figure 1 FUNCTION The actuator Manual operation The step motor of the actuator turns a There is a manual operation handle on screw via a gear wheel.
  • Page 3 MOUNTING The actuator may be mounted horizontally, vertically and in any position in between, but not upside down, see figure 3. N.B.! Do not use the actuator for the DN15 valves V298, V282, V294, V384, V386 and V394. To mount the actuator on a valve, slide the actuator onto the valve neck, thus making the square nut on the valve spindle fit into the groove on the cross...
  • Page 4: Wiring Examples

    Forta Modulating control, 24 V AC supply to the controller (TAC 239W, TAC 6711, TAC Xenta, TAC 8000, TAC 230U, TAC 2000, TAC 9000, TAC 77xx) Normal installation (5 wires to the actuator) Short cable installation (4 wires to the actuator)
  • Page 5 SETTINGS Function in the Description “OFF” position “ON” position Modulating Increase/decrease Control – – – – Sequence Control 2-10 0-10 2-10 V 0-10 V Voltage range 6-10, 5-10 2-6, 0-5 6-10 V, 5-10 V 2-6 V, 0-5 V Part of voltage range 0% / 60 s 300 s / 50% 60 s, 0%...
  • Page 6: Actuator Installation

    OP position. MAINTENANCE ACCESSORIES Circuit board, M400 ................1-001-0671-0 The actuator is maintenance-free. TAC Forta Handbook (GB) ..............0-004-7804 S2-Forta ....................880-0104-000 TAC AB, Jägershillgatan 18, SE-213 75 MALMÖ, SWEDEN, +46 40 38 68 50 (switchboard), www.tac.com 0-003-2060-1 (EN) 6 (6)

Table of Contents