316
Concrete
Tensile
Corrosion
zone
resistance
Basic loading data (for a single anchor)
All data in this section applies to
Correct setting (See setting instruction)
■
No edge distance and spacing influence
■
Steel failure
■
Base material thickness, as specified in the table
■
Embedment depth, as specified in the table
■
Embedment depth and base material thickness for the basic loading data
Recommended loads
Anchor size
Typical embedment depth h
Base material thickness h [mm]
Recommended loads
Anchor HIT-Z
Anchor size
Tensile N
[kN]
rec
Shear V
[kN]
rec
Note: For varied embedment depths please contact your local Hilti engineer for further details.
page 1
European
CE
PROFIS
Technical
conformity
anchor design
Approval
software
[mm]
ef
Hilti HIT-HY 200-R
500 ml foil pack
(also available as 330 ml
foil pack)
Static mixer
HIT-Z
HIT-Z-R rod
No cleaning
Seismic
Diamond
required for
drilled
approved
holes
loads
One anchor material, as specified in the tables
■
Non cracked concrete f
■
Temperate range I (min. base material temperature -40°C, max.
■
long term/short term base material temperature: +24°C/40°C)
Installation temperature range -10°C to +40°C
■
M8
M10
80
90
140
150
M8
M10
11.4
18.1
6.9
10.9
Product Data Sheet
HIT-HY 200
with HIT-Z
Benefits
■
no cleaning required: zero
succeptability to borehole cleaning
conditions with dry and water
saturated concrete base material
■
maximum load performance in
cracked concrete and uncracked
concrete
■
suitable for cracked and non-cracked
concrete C 20/25 to C 50/60
■
suitable for use with diamond cored
holes in non-cracked or cracked
concrete with no load reductions
= 32 MPa
c,cyl
M12
M16
110
145
170
245
M12
M16
25.9
45.7
15.4
27.4
M20
180
280
M20
69.5
41.7
February 2014