GFE-SWR - INSTALLATION MANUAL - 12/2016 Contents 1. Safety instructions ....................................... 3 2. Data Sheet .......................................... 4 3. Function of the detector ....................................... 6 3.1 Settings ........................................7 4. Installation: Mounting and orientation .................................. 7 4.1 General planning guidelines ..................................8 4.2 Performance-requirement A, B and C ................................
GFE-SWR - INSTALLATION MANUAL - 12/2016 Check the website www.sense-ware.com www.globalfire.pt for the latest information and latest version of this manual as well as the applicable Declaration(s) of Conformity. Due to the policy of continued product development SENSE-WARE Fire and Gas Detection BV reserves the right to alter or amend information in their publications without prior notice and no responsibility can be accepted for errors or omissions.
The UV/IR and IR3 flame detectors have a good false alarms rejection. The UV is insensitive to practically all false alarm sources, except for arc welding. Common applications in which the three GFE-SWR series flame detector models can be used can be found in the table below. Contact us if your application is not mentioned in this list.
Page 5
IR3 flame detector, EN54-10 certificate, suitable for ATEX zone 2/22, FM3260 and FM3611 approval GFE-SWR-BKT Swivel Mount with angle markings GFE-SWR-LMP Test lamp for GFE-SWR series flame detectors, including univ. charger &carrying case, non EX GFE-SWR-LMPIS Test lamp for GFE-SWR series flame detectors, including carrying case, intrinsically safe (pending) globalfire.pt...
GFE-SWR - INSTALLATION MANUAL - 12/2016 3. Function of the detector The LEDs on the display The GFE-SWR flame detector has 3 LEDs on the display. These have the following meaning: Continuous green: normal operation Continuous yellow: fault ...
GFE-SWR - INSTALLATION MANUAL - 12/2016 Remarks: Caution: during a manual optical self-test, the alarm relay is energized, when the test is successful. Make sure that before you start a manual self-test the outputs of the control panel or PLC are disconnected. Reconnect the outputs after you have finalized the self-test. Wiring the manual self-test is explained in the section electrical installation.
GFE-SWR - INSTALLATION MANUAL - 12/2016 4.1 General planning guidelines A flame detector is a detector which is suitable for fast detection of open fires. These are typically fluid and gas fires but can also be solids such as paper or wood. Flame detectors are “line of sight”...
GFE-SWR - INSTALLATION MANUAL - 12/2016 4.4 Orientation By mounting the flame detector with an angle of 45 heading to the bottom, you make full use of the cone of vision of the flame detector. If, seeing from the top, the flame detector also is directed diagonally, a volume is monitored. Top view 4.5 Shadow effect As rule of thumb you can take that the mounting...
GFE-SWR - INSTALLATION MANUAL - 12/2016 4.6 Voting The flame detector will not give an alarm until several alarm criteria are met at the same time. The probability of a false alarm is therefore very low. The flame detector is for this reason suitable for an extinguishing action based on the signal of one flame detector.
GFE-SWR - INSTALLATION MANUAL - 12/2016 Remarks: With the optional GFE-SWR-BKT ) swivel mount a convenient alignment of the flame detector on the fire risk is possible. (SM21 We strongly recommend applying the GFE-SWR-BKT ) 1 swivel mount. (SM21 6. Installation: Electrical The flame detector has several wiring options;...
GFE-SWR - INSTALLATION MANUAL - 12/2016 Connection diagram 6.1 Wiring: Fire Control Panel The flame detector can be electrically connected to a fire control panel the same way that a manual call point is connected; by means of the current increase principle. The flame detector is connected to the fire panel with 3 or 4 wire cables. 2 wires for the power supply wiring and 1 or 2 wires for the zone.
GFE-SWR - INSTALLATION MANUAL - 12/2016 Principle: The zone uses the alarm contact and the fault contact of the flame detector plus resistors. In case of a detector fault a wire breakage is simulated. In case of a fault followed by an alarm, a current Vn/AL is flowing through the zone. Thus an alarm “overrides”...
GFE-SWR - INSTALLATION MANUAL - 12/2016 6.3 Installing the manual self-test For the installation of the manual self-test in this section, 4 options are shown by means of a scheme: Flame detector connected to a fire control panel, with a self-test switch on the fire control panel. Flame detector connected to a fire control panel with a separate switch for the manual self-test.
GFE-SWR - INSTALLATION MANUAL - 12/2016 7.1 Commissioning Before the flame detector is activated, the following steps must be executed: Clean the detector window. Close the housing of the flame detector. Check the position and the alignment of the flame detector. Check if there are potential false alarm sources in the sight of the flame detector.
GFE-SWR - INSTALLATION MANUAL - 12/2016 8. Maintenance Except for cleaning there is no specific preventive maintenance needed. Inspection of the following items is necessary: Check the position and the alignment of the flame detectors. Check if there are no potential false alarm sources in the sight of the flame detector. Check if there are no obstacles which restrict the sight of the flame detectors.
GFE-SWR - INSTALLATION MANUAL - 12/2016 10. Appendices 10.1 Appendix A: EU-Declaration of Conformity - CPR 305/2011/EU In accordance with EN/ISO/IEC 17050-1:2010 Manufacturer: Sense-WARE Fire and Gas Detection B.V. Storkstraat 7, NL- 3905 KX Veenendaal, the Netherlands, EU Declaration: This declaration of conformity is issued under the sole responsibility of the manufacturer. Description: UV, UV/IR and IR3 flame detectors Brand Name:...
GFE-SWR - INSTALLATION MANUAL - 12/2016 10.2 Appendix B: EU-Declaration of Performance - CPR 305/2011/EU 1.Unique identification code of the product: Flame detector – Point detector UV-185/5CZ, UV/IR-210/1CZ or IR3-109/1CZ 2.Type or Serial Number or any other element allowing identification of the construction product as required under Article 11(4) of the CPR: See flame detector Face Plate as well as the original Packing List 3.Intended use or uses of the construction product, in accordance with the applicable harmonized technical specification, as foreseen by the manufacturer:...
GFE-SWR - INSTALLATION MANUAL - 12/2016 10.5 Appendix E: North American approvals – cFMus class 3611 & FM class 3260 All drawings and other details are listed in the “Document List 210-series flame detector”. FM approvals for the: UV-185/5CZ UV Flame Detector UV/IR-210/1CZ UV/IR Flame Detector IR3-109/1CZ IR3 Flame Detector Nonincendive per FM class 3611: Class I, II, III, Div.
Page 22
GFE-SWR - INSTALLATION MANUAL - 12/2016 Performance per FM class 3260:2000 Operating temperature : -40 C to +70 Response characteristics Fuel UV-185/5CZ UV/IR-210/1CZ IR3-109/1CZ time n-Heptane, 1 sqft 82 ft (25 m) 82 ft (25 m) 115 ft (35 m) within 10 sec.
Page 23
GFE-SWR - INSTALLATION MANUAL - 12/2016 GLOBAL FIRE EQUIPMENT S.A. Sítio dos Barrabés, Armazém Nave Y, Caixa Postal 908-Z, 8150-016 São Brás de Alportel - PORTUGAL Tel: +351 289 896 560 • Sales: sales@globalfire.pt • Technical Support: techs@globalfire.pt • www.globalfire.pt...