Charge controller with lcd-multi-function-display (18 pages)
Summary of Contents for SilentWind MPPT HYBRID BOOST CHARGE CONTROLLER
Page 1
MPPT HYBRID BOOST CHARGE CONTROLLER Rev.1 USER MANUAL INSTALLATION – OPERATION February 2019...
Page 2
MPPT Charge Controller User Manual - Feb. 2019...
Page 3
HYBRID BOOST CHARGE CONTROLLER Rev.1 - MPPT Congratulation! You have bought a high-quality hybrid charge regulator. Hybrid Boost Charge Controller is specially developed for the Silentwind generator. The Warranty Terms are described in a chapter of this manual. For traceability under the warranty, please register the...
Page 4
MPPT Charge Controller User Manual - Feb. 2019...
➢ This manual should always be kept near the Hybrid Boost Charge Controller. ➢ Silentwind cannot be held liable for any direct or indirect loss or damage, due to an incorrect operation or improper device handling. ➢ To avoid a risk of fire and electric shock, make sure the existing wiring is in good conditions and that the wires are connected tightly ➢...
Hybrid Boost Charge Controller or over the Silentwind APP available for Android and iOS devices. The Silentwind generator is a 3 phase AC voltage and in the Hybrid Boost Charge Controller AC is transformed to DC voltage. The voltage of the Silentwind generator and the...
Max. voltage adjustable for the battery types Acid, Gel, AGM and Lithium LCD + LED displays W, A, V, Ah 3.2 MPPT HYBRID BOOST CHARGE CONTROLLER - MECHANICAL DATA Weight 2.30 kg Package dimensions 220 x 150 x 83 mm...
3.5 LCD INFORMATION Name Icon Status Rotate means wind turbine works normally. Wind turbine BRAKE Brake by hand. Day. Solar Night or Panel Solar is not connected. Charging. Battery Fully charged. Flickering for over voltage. Stop flickering when it recovers from over voltage. Flickering means over-discharge.
Page 11
Name Icon Status Light control on/off. Light control on, time control off. Light control on voltage. Load output When “ON” & “LOAD “appeared, load is always on. Control mode Light control off voltage. Show “OFF” and time. The time is the control off time.
3.6 LCD DISPLAY Interface Display Interface Interface Introduction Introduction Battery Voltage Wind turbine Voltage Accumulative total Wind turbine electricity Current consumption Accumulative total Wind turbine Solar generation Power capacity Accumulative total Solar Panel voltage wind turbine generation capacity Light control off Solar Panel current voltage Light control on...
WHEN WORKING IN THE SYSTEM: Disconnect the Silentwind generator (to avoid risks, once you remove the 3 wires from the generator, please put at least 2 wires from the generator together to cause a short circuit and slow down the rotation of the blades).
Always ensure enough ventilation in battery location. 5.3 REQUIRED TOOLS AND EQUIPMENT Cable with the required length and diameter to connect the three AC phases from the Silentwind generator to the Hybrid Boost Charge Controller. Connectors for the three-phase cables to connect to the wind generator.
For protection against high voltage spikes and/or an accidental short-circuit event, fuses must be installed in the positive (red) wires to the battery. The required value of the fuse depends on the rated current of the Silentwind generator and solar panels connected to the Hybrid Boost Charge Controller.
5.5 PHYSICAL INSTALLATION Hybrid Boost Charge Controller should be installed in a wall using four screws with the panel upright (if you can read the front panel text horizontally then this is correct). The side panels and back are a heat sink to dissipate heat, which is why the orientation is important. To guarantee the lifespan, it is suggested that the space around the device has no other items within 30cm.
Hybrid Boost Charge Controller. After the connection of the battery you can connect the solar panel, the Silentwind generator and if required, a Load Output with 10A maximum on Output 1 and 10A on Output2 with 10A maximum. MPPT Charge Controller User Manual - Feb. 2019...
5.6.1 SOLAR PANELS Connect the terminals of solar panels to “SOLAR INPUT” terminals “+” and “-“ on the Hybrid Boost Charge Controller. All Solar panels rated voltages on this chapter are open circuit voltages (Voc). Check your solar panels datasheets for detailed information. Do not exceed your charge controller’s maximum wattage, voltage and amperage.
Page 19
24 Volt System SINGLE PANEL PARALLEL CONNECTION 12V PANELS – SERIAL AND PARALLEL CONNECTION MPPT Charge Controller User Manual - Feb. 2019...
Page 20
48 Volt System 24V PANELS - SERIAL AND 12V PANELS – SERIAL AND PARALLEL CONNECTION PARALLEL CONNECTION MPPT Charge Controller User Manual - Feb. 2019...
The Break Adjustment of the Hybrid Boost Charge Controller generates internal rising temperatures that are thermically detected. Therefore, the break time of the Silentwind Generator will be increased in high wind speeds until the internal temperature is reduced by dissipation. For this reason, the...
The End of Charge Voltage is critical. The Storm Brake is critical. Silentwind cannot be held responsible for bad parameter settings that might permanently damage your batteries, your charge controller and your wind generator. If you need to change the parameters, it can be done directly on the Hybrid Boost Charge Controller or through APP.
Page 23
See the following table for specific parameter setting. Scroll down to the display you want and press for 2s to go to the desired settings. After setting the parameters, press for 2s to leave the SET mode. Settings Interface Introduction Display Interface End of charge voltage Battery Voltage...
5.7.2 SILENTWIND CONTROLLER APP The Silentind Controller APP is available on the Google Play for Android devices and Apple Store for iOS devices. Go to your app store, according the operating system of your phone, and search for: SILENTWIND. Download the app and install it as any other APP. Compatibility information is displayed at the download section.
Page 25
6. Click on settings 5. Set the parameters accordingly 7. Click on Save Data The above pictures were taken from the v1.3.3 version and can differ from the present versions. For further information please visit our download section at: https://www.silentwindgenerator.com/en/download/ MPPT Charge Controller User Manual - Feb.
Fastened securely to the mounting location? All screw terminals firmly tightened? 6. OPERATION If windspeed is enough, the Silentwind generator should start charging. You can control this on the LCD display of the Hybrid Boost Charge Controller or from your smartphone or tablet using Silentwind generator APP available on Android and iOS devices.
How to disconnect the charge controller (wind, solar, battery): Disconnect the Silentwind generator (to avoid risks, once you remove the 3 wires from the generator, please put at least 2 wires from the generator together to cause a short circuit and slow down the rotation of the blades).
8. TROUBLESHOTTING 8.1 No display on LCD Description Possible reasons and solutions The connection between the battery and the Check the wiring and reconnect it. controller is not tight. Description Possible reasons and solutions DC breaker is not on between battery and Turn on the breaker.
8.3 No charging Description Possible reasons and solutions The connection cable between wind turbine and Reconnect the cable tightly. controller is loose. Description Possible reasons and solutions Wind turbine output voltage do not reach the Check if the system voltage is correct. charging voltage.
́ s name and address, the serial number and the date of purchase of the product. If you experience any problem with your Hybrid Boost Charge Controller, please contact: - Rulis Electrica – support@silentwind.com - Authorized service dealers – https://www.silentwindgenerator.com/en/silentwind-in-the- world/...
Page 31
Rulis Electrica Lda does not warrant the following: - Defects caused by modifications carried out without approval. - Damage caused by improper use, handling or operation, in particular defects caused by improper installation and installation on inadequate masts or support structures. - Accidents or disasters or any cause, including but not limited to lightning, flooding, fire etc.
Page 32
The requests must be done were you bought the SILENTWIND Pro. If for some reason the request is done directly to SILENTWIND, it will be first submitted for approval. The requests can be done through our online Helpdesk platform at: https://silentwind.vhdeu.com or sending an email to: support@silentwind.com...
Need help?
Do you have a question about the MPPT HYBRID BOOST CHARGE CONTROLLER and is the answer not in the manual?
Questions and answers