• Mount the Solar Eclipse so that it is inaccessible to anyone in the pool. Never attempt any servicing while unit is wet. • Warning - Short-term inhalation of high concentrations of ozone and long term inhalation of low concentrations of ozone can cause serious harmful physiological effects.
PANEL INLET INDICATOR 2B. Location LIGHTS The Solar Eclipse unit is designed for floor OUTLET mounting. Locate the unit in a clean, protected area, either indoors or outdoors (preferably out of direct sunlight). If possible, locate the unit out WARNING of reach of sprinklers or drainage spouts.
Solar Eclipse operates simultaneously with the pool pump. The Solar Eclipse has four The Solar Eclipse will come with one half of a union available knockouts for a 1/2” conduit fitting, two fitting installed on Inlet and Outlet, the other half of on the back and one on each side.
4A-1. Ozone Module external indicator lights, red and green, on its The Solar Eclipse is constructed with 6 Corona left side. When the Solar Eclipse has power, the Discharge Ozone Modules. Each Ozone Module green Power Light will illuminate. The red Vacuum has a green light to indicate that the Ozone Power Indicator may be on momentarily.
10 in/lbs or the component may be Modules, shut down the Solar Eclipse immediately damaged. and replace the Ozone Gas Line. If water entered the Solar Eclipse, allow the unit to dry completely before restarting the unit. OzONE GENERATOR...
4. The Base will remain firmly mounted with all the components fully accessible for servicing. UV REACTOR 4C-2. Replacing an Ozone Module LAMP 1. Open the Solar Eclipse as described in Section CUSHION 4C-1. Figure 6: UV Reactor Subassembly 2. Locate the Ozone Modules on the left wall of the enclosure.
Note: The quartz Tube will rest on a spring system is on. in the bottom of the UV Reactor. Gently press 1. No power to the Solar Eclipse from the Power the quartz Tube downward and feel for the Source: spring to push back to confirm that it is properly a.
Solar Eclipse Installation & Operations Manual Symptom: One or both the UV Lamps are not lit when unit it running. 1. Check Lamp Connector Plug for complete connection. 2. Water fouling has shorted lamp connections. 3. Bad UV Lamp. 4. Bad Ballast.
After this information is provided, DEL Ozone may release a RETURN GOODS AUTHORIZATION (RGA) NUMBER. After receiving the RGA number the part in question must be returned to DEL Ozone, freight prepaid, with the RGA number clearly marked on the outside of the package. All preauthorized defective parts must be returned to DEL Ozone within thirty (30) days.