Table of Contents Evolve™ — A New Cold Has Arrived ..............5 SilverCore Solid State, Compressor-free Refrigeration System ........5 SilverPoint Temperature Monitoring Upgrade ............5 Using SilverPoint to Monitor Temperature Data ............. 5 SilverPoint Network Setup Detail ..............6 SilverPoint User Setup ..................
Page 3
Evaporation Tray ..................20 Product Interior ..................20 Interior Components ................. 20 Adjustable Shelving .................. 21 Navigating Evolve 5.5 cu. ft. Refrigerator Controls ..........21 System Icons ..................... 21 System Prompts ..................22 System Alerts .................... 22 System Alert Values ..................23 Reading the LCD (Temperature) Display ............
Page 4
Defrost ....................35 Date / Time ................... 36 Protect Plus Only: Lighting ................ 37 WiFi Connection ..................37 Model Information ................... 38 Administrator Tools ..................38 Protect Plus Only: Edit Users ..............38 Protect Plus Only: User Accessibility Levels ............ 39 Menu Access ..................
Evolve™ — A New Cold Has Arrived Phononic is changing the paradigm of refrigeration with Evolve. Evolve products operate with a patented SilverCore refrigeration system and optional embedded temperature monitoring system called SilverPoint™. The Evolve family of products dramatically modernizes cold storage technology for medical and healthcare facilities and offers a complete solution for protecting vaccines, medications, and temperature-sensitive materials.
Network Interface DHCP Supported Connection Device bridge service protocol Device bridge evolve-units.phononic.com/bridge service URL Data bridge 7777 service port <<1Mbps Data rate (approx. 1KB per 15 minutes) HTTP Portal protocol portal.phononic.com/evolve Portal URL Portal Port SilverPoint User Setup New Administrator Account Registration A new user can start the registration process from the portal landing page: (http://evolverefrigeration.com/silverpoint-temperature-monitoring...
New Unit Registration A new unit can be registered from the dashboard by clicking on the 'Register/Add Unit' button. The administrator may now enable/disable e-mail alerts, manage units, manage users, and view/manage unit data. (NOTE: To receive e-mail alerts, the administrator and their assigned users must check the box...
We’ve now advanced our commitment with the Evolve 5.5 cu. Ft. Protect Plus refrigerator achieving ENERGY STAR® certification in the Laboratory Grade Refrigerator and Freezer category.
For any damage done to the refrigerator, please contact the delivery carrier directly. Do not call the Evolve service line to report shipping damages. Call your carrier. We have designed intelligent packaging to assist you in unpacking your Evolve compact refrigerator.
Providing Ventilation Your Evolve medical-grade undercounter refrigerator is equipped with a ventilation area just above the door handle. Do not block or cover the venting area as this can impact the performance of the refrigerator. The fans on your product will run at intervals of variable speeds and may turn off completely.
Powering On and Power Cord Guidelines 1. Use only the power cord provided with your Evolve undercounter refrigerator. 2. Plug the power cord into the receptacle on the upper rear of the refrigerator as indicated. Secure the strain relief to ensure the cord cannot accidentally pull out.
Uninterruptable Power Supply (UPS) Your Evolve refrigerator is compatible for use with a UPS battery backup. The primary role of any UPS is to provide short-term power when the input power source fails. If you use a UPS backup, take care to follow the directions and precautions accompanying that device.
Checking the Glycol Sample Bottle The glycol sample bottle is pre-installed inside your unit. The sample bottle allows you to monitor the internal temperature of items being stored in the refrigerator. Please verify: 1. The cord for the sample bottle is fully plugged into the back wall of the interior of your unit.
Preset alarms/alerts The following alarms/alerts are factory preset: Alarm Factory Setting Icon Min 2 °C Max 8 °C Temperature Range Alarm 1 minute Door Ajar Alarm Instantaneous No Power Alarm Battery Low Alarm < 30% Remaining < 30% Remaining Memory Full Alarm >60 seconds disconnected No Wifi Alarm Set Point Temperature...
1 minute. Automatic Defrost Cycles The Evolve refrigerator will run a pre-programmed automatic defrost cycle every 24 hours. During the defrost cycle you will likely hear the fan turning off and on. In addition to the...
Getting to Know Your Product Product Exterior – Front Touch-screen Display The touch-screen display is located in the center of the upper console and is the single point- of-use for controlling the refrigerator. The display is 4.3” diagonal; landscape orientated and full-color TFT-LCD supporting 65K color.
Input / Output Dock USB Port A USB port is available to download the data log of the optional SilverPoint local temperature monitoring to a USB memory device. You will use the USB port to download and clear the data log when the storage is full. The USB port is also used to update the firmware.
Ventilation The Evolve refrigeration system is a solid-state system utilizing fans with moving parts. The functioning of the fans is integral to heat dissipation. The fans are mounted on the top of the unit. They will run continuously until the preprogrammed temperature set point is achieved.
Evaporation Tray The evaporation tray is located on the bottom rear of the unit to collect and evaporate condensation. Product Interior Interior Components Glycol temperature sensor port and sample bottle • Air temperature sensors (2) • External pass-through port • Adjustable shelving •...
Adjustable Shelving Your Evolve undercounter refrigerator is shipped with wire ties holding the shelves in place. Remove the wire ties before using the refrigerator. You may place the shelving wherever you choose by removing and relocating the support clips. Navigating Evolve 5.5 cu. ft. Refrigerator Controls...
System Alert Values Alarm Factory Setting Icon Temperature Min 2 °C Max 8 °C Range Alarm 1 minute Door Ajar Alarm Instantaneous No Power Alarm Battery Low < 30% Remaining Alarm Memory Full < 30% Remaining Alarm >60 seconds disconnected No Wifi Alarm Reading the LCD (Temperature) Display The Temperature Display is preset to show the Glycol Sensor reading, measured in...
Protect Plus Only: Login and Unlock Door Login 1) Tap inside the green circle to bring up the Password/Pin entry screen 2) Tap in the appropriate 4-digit Password/Pin (a Universal Password/Pin is provided with the unit and must be entered upon the first/initial login) 3) Tap/Select the Check button Unlock/Lock Door 1) After entering the Password/Pin, tap/select Unlock...
Access the Main Menu 1) Tap the menu icon in the lower right corner of the display. Alarms Alarm Overview Default Setting Setting Options Visual Audible Type On/Off Door Ajar Door Ajar 60 seconds 60, 90 or 120 seconds Interval 4.5-9 °C Temperature (.5 °C) Increments...
Page 26
Memory On/Off Remaining Memory Off,10%, 20%, 30%, 40%, Remaining Interval On/Off Battery Battery Off,10%, 20%, 30%, 40%, Remaining Interval On/Off Power Out 1) Active Alarms The Active Alarms screen displays a list of active alarms and is one of the ways that an alarm can be cleared.
Data Log Settings is where the user can view and edit the Data Log frequency. The data log feature is part of the local temperature monitoring accessory and can be added to any Evolve refrigerator. Contact your sales representative for more information.
Page 28
Temperature °C °C/°F Units Temperature Whole Whole/Tenths Precision Temperature Glycol Glycol/Air Display Interior Off, 10%, 20%, 30%, 40%, 50%, 60%, Lighting 70%, 80% 90%, 100% Brightness Lighting Door On/Off Open Lighting 10 seconds 1-30 seconds Duration After Close Lighting Door On/Off Closed Off, 10%, 20%, 30%, 40%, 50%, 60%,...
1) Temperature Temperature Set Point is where the user sets the desired temperature in °C or °F (4 °C is the default temperature setting) 2) Temperature Display Settings Temperature Display Settings is where the user determines and sets the desired details of the displayed temperature. As in Air or Glycol, units in °C or °F and whole or tenths of units.
2) Firmware Firmware is the Admin Tool used for updating a new Firmware version. 3) Calibration Calibration is where system offsets are entered or modified. Calibration edits require an Administrator PIN or password to complete. 4) Load Settings Load settings allows you to load pre-configured settings to a refrigerator. Alarms Active Alarms The Active Alarms screen displays a list of active alarms and is one of the ways that an...
Alarm Setting options. Use the up or down arrow to scroll through the settings. Data Log Data log is part of the local temperature monitoring accessory and can be added to any Evolve refrigerator. Visit portal.phononic.com for more information.
Selecting the Download Data Log will prompt the user to insert a USB drive. Once the USB drive is inserted, the user is notified that the USB drive has been detected by the system. The user then selects Download from the display and once the data download is complete (normally just a few seconds), the user is prompted that the Data Log has been saved to the USB drive.
Reviewing / Adjusting Data Log Settings In the Data Log Settings menu, the user can turn on or off the on-board data logging feature, set the time for Data Log Intervals, turn on or off the Cloud Data Log and adjust the Cloud Sync Interval (the intervals that the unit pushes/sends data to the cloud).
0.5 degree increments whether the display is set to Celsius or Fahrenheit. Setting the proper desired temperature is one of your most important display settings. The Evolve 5.5 cu. ft. Medical-grade Refrigerator will hold your set temperature to within 0.5 °C.
Date / Time Select Date / Time to manually set-up the current date and time. The initial screen shows the time and date entered and prompts the user to set the time and date. When setting the time, the user can select between a 12 and 24-hour clock (standard time or military time) and AM or PM for a standard clock setting.
Protect Plus Only: Lighting Select Lighting to adjust the brightness level, lighting on with door open and the duration of the lighting to remain on after closing the door. WiFi Connection...
Select WiFi Connection to view the list of detected networks. Once the desired network is selected, the user is prompted to enter the network password using the full touch-screen keyboard. SilverPoint remote temperature monitoring can be added to any Evolve refrigerator. Visit portal.phononic.com for more information.
User Accessibility Levels Protect Plus Only: User Level Menu Access Alarms, Data Log, Settings, Administrator Tools Admin Alarms, Data Log, Settings Sub-Admin Alarms, Data Log User Firmware Firmware updates are conducted via the Admin Tools. A firmware update is in a BIN file format.
prompted to insert the USB drive. Once the BIN file is located and selected by the system, the user taps Apply. The control will then display a screen acknowledging that the new, updated firmware is being applied. When the upload is complete the display screen will confirm that the new firmware has been successfully applied.
Periodic Product Maintenance Use of cloth to wipe interior With cold wall refrigerators, condensation may form on the interior of the cabinet and may require periodic wipe-down with an absorbent cloth. Suitable products for cleaning interior/exterior The interior may be cleaned, when needed, using a mild detergent and a damp cloth. Important - avoid the use of chlorides (cleaners with bleach) as well as abrasive cleaners and scrubbers such as steel wool.
Frequently Asked Questions How does this refrigeration technology work? Evolve is built on the SilverCore refrigeration system. It uses a non-toxic, non-hazardous refrigerant embedded in the walls to absorb and channel heat energy to an internal, solid- state heat pump: the component that replaces the compressor in a typical refrigerator. The heat pump cools the refrigerant material when it channels the heat energy out of the system and into the ambient environment.
Page 43
How long before I can use the product? In a normal ambient environment, your refrigerator should pull down to the target set point within a couple of hours. It is common industry practice to monitor the unit over 48 hours to ensure it is holding the set point temperature.
Troubleshooting Troubleshooting Problems Customer Resolution Check for proper installation of the Unit doesn't power on power plug. Did you just power up the • refrigerator and is the system pulling down to set point temperature? Alarm will not sound until the set point is met Unit's audible alarm doesn't sound (4 °C default) when out of temp range?
Page 45
cycle. Run a manual defrost cycle if desired. Check to make sure something isn't blocking it from closing completely. Door doesn't close/closes incorrectly Check to make sure the door is properly aligned in the frame by looking for uneven surfaces. For Door alarm keeps sounding example, is the gap from the hinge to edge equal in width all the way across...
Page 46
few attempts, try inserting a different USB memory stick. Contact Phononic customer service if this persists. Did you confirm there is a USB icon on the icon bar? Is the LED on USB illuminating? Check the USB device to System doesn't download data to the make sure there is space for the data file.
Page 47
WiFi-related Issues Is the router within range? Have you tried to manually enter a network name? Consult your I can't find my network system administrator for help with your network id & password. Is the router within range? Have you tried to manually enter a network name? Have you changed the password recently? Consult your I can't connect to my network...
Page 48
Do you see a cloud indicator on the display? If so, the unit is trying to send data to the cloud and is likely trying to establish a WiFi connection. Allow the WiFi connection to cycle My user display is through its process before trying to access the unresponsive user interface buttons.
Product Warranty and Service Phononic warrants to the original purchaser that the equipment shall be free from material defects in material and workmanship under normal use and service during the “Warranty Period,” defined as a period of 2 years from date of purchase with respect to all parts, during which period Phononic shall cover the cost of parts and labor for repair and replacement, and (ii)
Product Specifications General Specifications and Features Model Number ELR055SSB-XXX Solid Door ELR055SGB-XXX Glass Door Model Style 5.5 cu. ft. medical-grade undercounter refrigerator Durable painted steel exterior with easy-to-clean Materials interior aluminum walls 5.5 cu. ft. / 156 liters Internal Chamber Capacity Chamber Temperature ±1 °C / ±1.8 °F from center air temperature Uniformity...
Page 51
Physical Dimensions 125 lbs. / 56.8 Kg Weight 600 mm W x 653 mm D x 813 mm H Outer Dimensions 23.6” W x 25.7” D x 32” H 495 mm W x 521 mm D x 584 mm H Internal Dimensions 19.5”...
In order satisfy the FCC RF exposure limit for transmitting devices, a separation distance of 20 Radiation cm should be maintained between the body and the Evolve refrigerator while in operation. Hazard This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject...
Wiring Diagram Provided for informational purposes only. For repairs or operating issues, please contact Customer Care at 1-844-476-4202. Wiring diagram for Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator...
Safety Precautions All electrical appliances present some risk of injury. Your Evolve refrigerator is designed to meet safety standards. Take care to carry and move your refrigerator with caution. Do not place it where it can fall, be dropped, or where the electrical connection can be submerged into water or other liquids.
Need help?
Do you have a question about the ELR055SSB Series and is the answer not in the manual?
Questions and answers