4.3.
Lamp Replacement (fig.5). (The IR3000 is supplied with the lamps fitted, follow the procedure below when replacement lamps required)
WARNING! Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains
supply.
4.3.1.
The lamp used in the fitting is robust and if knocks and shock vibrations are avoided, will last for around 5000 hours.
4.3.2.
Isolate the complete unit from the power supply and then wait until the cassette body has cooled down.
4.3.3.
Remove the two screws from the one end of the reflector plate and remove that end reflector plate with the guard by gripping the guard
and carefully lifting outwards.
4.3.4.
Remove the other end reflector plate by removing the two screws and carefully lifting out.
4.3.5.
Carefully remove the lamp from the cassette and unclip the lamp terminal ends (both ends). If necessary, use two pairs of pliers to pull
terminals apart. Do not pull apart using the cables as this may result in the wire coming away from the crimped terminals.
4.3.6.
Replace with the new lamp making sure the lamp terminals are fully pushed together and insulated.
4.3.7.
Re-assemble making sure all the parts are replaced and the guard is in position (see Fig.5 below).
WARNING! Failure to reassemble all the parts and use the guard will invalidate any remaining guarantee and may make the unit
dangerous.
fig.5

5. OPERATION

Note:
The IR lamps are fragile and therefore it is important that the IR3000 is not subjected to any unnecessary shocks or vibration
and is not moved when the lamps are on or still hot.
5.1.
Digital Controller Operating Instructions
5.2.
Power On. Turn on the main power switch - display indicates OFF.
5.3.
Press Red On/Off button - the LED indicator shows the last memory used - e.g. Fig.6.