Setup Guide TS-EXPC & TS-EXPC2 Expansion Consoles for TS-5000 and TS-550 Franklin Fueling Systems • 3760 Marsh Rd. • Madison, WI 53718 USA Tel: +1 608 838 8786 • 800 225 9787 • Fax: +1 608 838 6433 • www.franklinfueling.com...
Page 2
Notice Franklin Fueling Systems (FFS) reserves the right to change this document and specifications at any time without notice. FFS makes no expressed or implied warranty with regard to the contents of this manual. FFS assumes no liability for errors or omissions, or for any damages, direct or consequential, that may result from the use of this document or the equipment that it describes.
Important Safety Messages Franklin Fueling Systems (FFS) equipment is designed to be installed in association with volatile hydrocarbon liquids such as gasoline and diesel fuel. Installing or working on this equipment means working in an environment in which these highly flammable liquids may be present. Working in such a hazardous environment presents a risk of severe injury or death if these instructions and standard industry practices are not followed.
Certified Programmer/Service Person: Only a Franklin Fueling Systems certified programmer or service person is allowed to access both the user interface keypad and areas internal to the Fuel Management System console. Station Owner/Operator: The station owner or operator of the Fuel Management System console is only allowed to access the user interface keypad.
Introduction The TS-EXPC and TS-EXPC2 are expansion consoles that include a Power Supply module and space for additional modules. The Expansion Console connects to your primary console via the bus extension port. Expansion Console Addition Modules Spaces TS-EXPC TS-EXPC2 The TS-EXPC and TS-EXPC2 lack Control Modules and LCD screens, so that it can operate efficiently as a secondary unit to house any additional modules that your primary console was unable accommodate due to space restrictions.
16.5" 8" (41.9 cm) (20.3 cm) 14.2" (36.1 cm) 11.1" 12.1" (30.7 cm) (28.2 cm) Figure 2: TS-EXPC Mounting Dimensions Connection The TS-EXPC and TS-EXPC2 have the normal Power Supply Module connections, but only the BUS EXT is active. Connect the BUS EXT High, Low and Ground on the main console to the High, Low and Ground on the expansion console. Installation Notes •...
Page 8
BUS EXT Figure 4: Jumper JP1 Location Bus Termination Jumper Removal The TS-EXPC / TS-EXPC2 provides system bus termination when installed and running. Therefore the system bus termination currently provided by the Power Supply Module must be removed. Leaving the jumper in place will result in erratic system performance.