Thank you for choosing our product. This instruction is intended to facilitate correct operation, safe use, and taking full advantage of the setter’s functionalities. Before you start the device, please read and understand this instruction. In the event of any additional questions, please contact our technical adviser. CONTENTS 1.
1. PRINCIPLES OF SAFE USE before you start to use the device, become familiar with the present instructions; make sure that all wires are connected properly to the tested item; wire connections must be modified only with voltage switched off; ensure proper operating conditions compliant with the technical specification of the device (signal level, humidity, temperature, etc.;...
NOTE: Before you start working with the setter, make sure to become familiar with this operating instruction and perform correct configuration of the parameters and make electrical connections. 3. CONTENTS OF THE SET setter with batteries power supply for battery charging operating instructions;...
Page 5
- do not connect the power supply to the instrument without the batteries installed - do not charge regular batteries (only rechargeable batteries may be charged) (4) – the estimated time of operation with new, fully charged rechargeable batteries is equal to >10 hours in the setting mode for continuous current value of 20 mA, >40 hours for continuous setting of voltage equal to 10 V, and >400 hours in the testing mode 5.
4. Installation of batteries in the compartment View from the bottom of the device after the cover is opened 6. BUTTON FUNCTIONS a) button functions in the set/measured value display mode (normal mode) Button Description [and marking in the contents of the instructions] [PWR]: - switches the device on/off (press for more than 1 second) [IN] or [OUT]:...
[UP] or [DOWN]: - moves to the next or previous parameter name - changes the value of the edited parameter [ESC]: - cancels the change of the edited value (and displays the parameter name again) - displays again the set/measured value (after holding time > 1 s) 7.
Page 8
Table 8. Configuration parameters Settings Parameter Range of variability of the parameter and description default 0-20 current signal in the 0÷20 mA standard (full range 0÷21 mA) current signal in the 4÷20 mA standard (full range 3.8÷21 mA) 4-20 1: StYP type of 0-20 output/input signal 0-10...
0000 ÷ 9999 17: PASS password password for the configuration menu (when 18: Prot = on ) 1111 18: Prot protection of entry into the configuration menu is not password-protected the configuration with a entry into the configuration menu is password-protected password time calculated from the time of last use of any keyboard key, 19: toFF auto-off time...
Figure 9.3. The principle of operation of outputs in the triangular wave generator mode (parameter riSE > 0, FALL > 0). 10. MESSAGE AND ERROR SIGNALING. DIAGNOSTIC FUNCTIONS. a) measurement and setting errors (diagnostic functions): Code Possible causes of error - the permissible measurement range/set signal is exceeded from above ( ^^^^ ) or from below ( ____ ) ^^^^ - the signal that is connected is different than the one that is set in the configuration (chapter 8, parameter 1:...