146
Troubleshooting the Kinetix 6000 Drive System
Interpreting Status
Indicators
Error
Fault Message
Code
RSLogix (HIM)
BusUndervoltage
Fault
E00
(Blown fuse)
MotorOvertemp
Fault
E04
(Motor Overtemp)
Publication 2094-UM001A-EN-P — September 2006
Refer to these troubleshooting tables to identify faults, potential
causes, and the appropriate actions to resolve the fault. If the fault
persists after attempting to troubleshoot the system, please contact
your Rockwell Automation sales representative for further assistance.
Error Codes
The following list of problematic symptoms (no error code shown)
and faults with assigned error codes is designed to help you resolve
anomalies.
When a fault is detected, the seven-segment LED indicator will display
an E followed by the flashing of the two-digit error code, one digit at
a time. This is repeated until the error code is cleared.
Seven-segment LED Indicator Error Codes
Problem or Symptom
Potential Cause
No ac power or auxiliary logic power.
Power (PWR) indicator not
ON
Internal power supply malfunction.
Motor wiring error.
Motor jumps when first
enabled
Incorrect motor chosen.
Digital I/O not working
I/O power supply disconnected.
correctly
A blown fuse was detected
Blown fuse.
on the inverter PCB
• High motor ambient temperature
• Excessive current
Motor thermal switch
tripped
Motor wiring error.
Incorrect motor selection.
and/or
Possible Resolution
Verify ac control power is applied to the
Kinetix 6000 system.
Call your Rockwell Automation sales
representative to return module for repair.
• Check motor wiring.
• Run Hookup test in RSLogix 5000
software.
Verify the proper motor is selected.
Verify connections and I/O power source.
Call your Rockwell Automation sales
representative to return module for repair.
• Operate within (not above) the
continuous torque rating for the
ambient temperature
40 °C (104 °F) maximum.
• Lower ambient temperature, increase
motor cooling.
Check motor wiring at MF connector on the
IAM/AM.
Verify the proper motor has been selected.
Need help?
Do you have a question about the Allen-Bradley Kinetix 6000 and is the answer not in the manual?
Questions and answers