Leonard 170-LF Installation Adjustment Service

Leonard 170-LF Installation Adjustment Service

Thermostatic / point of use mixing valves

Advertisement

MODEL 170, 170-LF, 270, 270-USW, 270-LF, 370, 370-LF, 470
THERMOSTATIC / POINT OF USE MIXING VALVES
170 (3/8"COMP)
170-LF (3/8"COMP)
ASSE 1070
170 WARNING:
DO NOT USE THREAD
SEALANT ON MODEL 170
COMPRESSION CONNECTIONS
270 / 270-LF / 370 / 370-LF / 470 WARNING:
When using flex hoses be careful, swivel connectors may damage inlet checks and / or element
on outlet on 270, 270-LF, 370, 370-LF and 470 models. Coupling fittings may be needed if
swivel connectors have a brass protruding tube or any protrusion that may damage the valve.
1. Valve should be installed where it can be easily cleaned,
adjusted or repaired.
2. Inlets are furnished with NPT connections. When
soldering close to this unit, DO NOT OVERHEAT,
internal components may become damaged.
WATER TEMPERATURES IN EXCESS OF 110°F (43°C) MAY CAUSE SCALDING, SEVERE
IMPORTANT! These thermostatic water mixing valves can be adjusted to deliver water at temperatures
exceeding 110°F (43°C). After installation, the installer must check the outlet water temperature and adjust
the temperature setting to ensure delivery of a safe water temperature not exceeding 110°F (43°C). See
p
"Temperature Adjustment" next page
INSTALLATION, ADJUSTMENT, SERVICE
270 (1/2"NPT)
270-LF (1/2"NPT)
ASSE1017/ASSE 1070
Maximum Operating Pressure: 125 PSI (860 KPA)
g
.
1360 Elmwood Avenue, Cranston, RI 02910 USA
Phone: 401.461.1200 Fax: 401.941.5310
Web Site: http://www.leonardvalve.com
270-USW (1/2")
( PICTURE NOT SHOWN )
ASSE 1017
ASSE 1070
3. Leonard recommends that unions and shutoffs are
installed on the inlets and outlet.
4. Use solder or pipe cement sparingly. Supply pipes should
be flushed before the valve is connected. Flush outlet
pipe and valve as soon as it is connected.
WARNING!!
WARNING!!
INJURY, OR DEATH!!
y
p
Email:
info@leonardvalve.com
Bulletin G-522
February 2013
370 (3/4"NPT)
370-LF (3/4"NPT)
ASSE1017/ASSE 1070
470 (1"NPT)
( PICTURE NOT SHOWN )
ASSE 1017
ASSE 1070
ASS 10 0
g
(
)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 170-LF and is the answer not in the manual?

Questions and answers

Summary of Contents for Leonard 170-LF

  • Page 1 Bulletin G-522 February 2013 INSTALLATION, ADJUSTMENT, SERVICE MODEL 170, 170-LF, 270, 270-USW, 270-LF, 370, 370-LF, 470 THERMOSTATIC / POINT OF USE MIXING VALVES 170 (3/8”COMP) 270 (1/2”NPT) 370 (3/4”NPT) 170-LF (3/8”COMP) 270-LF (1/2”NPT) 370-LF (3/4”NPT) ASSE 1070 ASSE1017/ASSE 1070 ASSE1017/ASSE 1070 170 WARNING: 270-USW (1/2”)
  • Page 2 1/WX Leaking water between valve cover and body. REBUILDING KIT Valve will not control temperature after REBUILDING KIT cleaning. Model 170, 170-LF R/170 Model 270, 270-LF, 270 USW 370 370 LF 470 270-USW, 370, 370-LF 470 R/270/370 R/270/370 CHECKSTOP KIT Hot water by-pass into cold line.
  • Page 3: Troubleshooting

    PART # 7539 DIAL PLATE RETURN SPRING SHUTTLE O'RING COVER KNOB SET SCREW MODEL 170, 170-LF, 270, 270-LF, 270-USW, 370, 370-LF, 470 MODEL 170, 170-LF MODEL 270, 270-LF MODEL 270-USW MODEL 370, 370-LF, 470 1/ WX Gasket Kit 1/ WX Gasket Kit...
  • Page 4 Leonard Valve Company's instructions, for a period of one year from date of shipment. During this period the Leonard Valve Company will at its option repair or replace any product, or part thereof, which shall be returned, freight prepaid, to the Leonard factory and determined by Leonard to be defective in materials or workmanship.

This manual is also suitable for:

270-usw170270-lf370470370-lf ... Show all

Table of Contents