Sapcon CAPVEL-ICT Instruction Manual

Capacitance level transmitter

Advertisement

INSTRUCTION MANUAL
CAPVEL-ICT
Capacitance Level Transmitter
Version 2.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CAPVEL-ICT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sapcon CAPVEL-ICT

  • Page 1 INSTRUCTION MANUAL CAPVEL-ICT Capacitance Level Transmitter Version 2.0...
  • Page 2: Table Of Contents

    7 Capvel-ICT Features ........
  • Page 3 Configuring and Asking Sensor ID on Network ....... . Sapcon Instruments Pvt.Ltd.
  • Page 4: Revision History

    Branding Revisions • Copyright: All content on this document, such as text, graphics, logos and images is the property of Sapcon Instruments Pvt. Ltd. The selection, arrangement and presentation of all materials on this document and the overall design of this document is the exclusive property of Sapcon Instruments Pvt.
  • Page 5: Introduction

    • Output-2 : Rs-485 Digital Data Capvel-ICT Features • User Interface : 4 Digit Display with 4 Keys + 2 • Output-1 : 4-20 mA, Galvanically Isolated •...
  • Page 6: Mechanical Specification

    • Capvel-BT : 9V to 55V DC • Capvel-ICT : 9V to 30V DC Power Consumption • Capvel-BT : Max. 0.5 watt @12 V • Capvel-ICT : Max. 1 watt @12 V Table 2: Electrical Specifcations Measurement Specification For Measurement Specification please refer Table 3...
  • Page 7: Installation Guidelines

    During installation, all electrical connections must be powered OFF and the fuel tank must be empty. 11.1 Tank Mounting Installation Note: It is recommanded that the tank must be empty while following steps in this section. Electrical Connections Calibration Sapcon Instruments Pvt.Ltd.
  • Page 8: Calibration

    Upper Calibration has done ! Now the Sensor is in RUN MODE again ! We can Calibrate 4mA and 20mA in any order according to our choice. The order of empty-fill or fill-empty is immaterial. Figure 3: Calibration Sapcon Instruments Pvt.Ltd.
  • Page 9: Tank Strapping

    Devices that work on capacitance principle for measurement of level of fluids, are for indicative purpose only. These devices should never be used for inventory control, weights and measures or any other place where highly accurate measurement of fluid level/volume/weight etc is needed. Figure 4: Tank Strapping Sapcon Instruments Pvt.Ltd.
  • Page 10: Error Display And Remedy

    Internal reference got short Internal fault in sensor circuited RFHI Internal reference satu- Internal fault in sensor rated RFLO Internal reference negligi- Internal fault in sensor Oscillations stopped Internal fault in sensor Table 4: Error Display and Remedy Sapcon Instruments Pvt.Ltd.
  • Page 11: Menu And Description

    SCAL-HIGH must be 20% or more Higher than SCAL-LOW SCAL (Scal Factor) SC.-L L.000<>L.080 Lower SCALE LEVEL SCAL-HIGH must be 20% or more Higher than SCAL-LOW dISP(Display) d.PER<>d.AmP Display Options PER : Percentage, AmP : mAmp Table 5: Menu Sapcon Instruments Pvt.Ltd.
  • Page 12: Rs-485 Serial Commands For Communication With Capvel

    Application Soft- <z,PER?>or <z,PER=00000,N> 0% (NORMAL) ware must have to take care <Z,PER?> <Z,PER=00000,L> 0%(LOW) of any possible errors dur- ing turn-on or off durations, change in nature of service material etc. Table 7: Percentage Level Information Sapcon Instruments Pvt.Ltd.
  • Page 13: Settings

    Thank you for going through the instructions given in this manual. To further ease the process of installation and use, we have developed special demo videos which are hosted on YouTube. Sapcon’s YouTube channel, SAPCON INSTRUMENTS, lists all these videos: https://goo.gl/dnxfcz Should you require further information regarding installation, use or working of the instrument, please don’t hesitate to contact us.